• 제목/요약/키워드: displacement ratio

검색결과 1,497건 처리시간 0.027초

Inelastic displacement ratios for evaluation of stiffness degrading structures with soil structure interaction built on soft soil sites

  • Aydemir, Muberra Eser
    • Structural Engineering and Mechanics
    • /
    • 제45권6호
    • /
    • pp.741-758
    • /
    • 2013
  • In this study, inelastic displacement ratios are investigated for existing systems with known lateral strength considering soil structure interaction. For this purpose, SDOF systems for period range of 0.1-3.0 s with different hysteretic behaviors are considered for a number of 18 earthquake motions recorded on soft soil. The effect of stiffness degradation on inelastic displacement ratios is investigated. The Modified Clough model is used to represent structures that exhibit significant stiffness degradation when subjected to reverse cyclic loading and the elastoplastic model is used to represent non-degrading structures. Soil structure interaction analyses are conducted by means of equivalent fixed base model effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. A new equation is proposed for inelastic displacement ratio of system with SSI with elastoplastic or degrading behavior as a function of structural period ($\tilde{T}$), strength reduction factor (R) and period lengthening ratio ($\tilde{T}$/T). The proposed equation for $\tilde{C}_R$ which takes the soil-structure interaction into account should be useful in estimating the inelastic deformation of existing structures with known lateral strength.

연약지반 성토시의 기울기변화를 이용한 안정관리기법에 관한 실험적 연구 (A Experimental Study on the Stability Management Method using change of Inclination for Embankment on Soft Clay)

  • 류지훈;임종철;장지건
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.898-905
    • /
    • 2005
  • The settlement of embankment on soft clay includes shear settlement due to shear deformation. Even though the consolidation settlement is not related to lateral displacement, but shear settlement makes the embankment unstable because it deforms ground and decreases the ground strength. In order to determine the shear deformation behaviour during embankment construction, 3 cases (1B, 2B, and 3B) of rapid undrained loading tests on soft clays were performed. Shear settlement is consist of elastic settlement, plastic settlement and viscous settlement. Elastic settlement isn't considered because the range is small, therefore the first is the range of plastic displacement, and the second is that of viscous displacement in the displacement-time curve for each loading stage. After determining that the change in the inclination of the viscous displacement range is larger than in the plastic displacement range after the ground failure occurs for the loading stage, the stability management methods were suggested considering that it is hard to divide the plastic displacement range and the viscous displacement range. The stability management method was based on the ratio of the plastic displacement range's inclination and the viscous displacement range's inclination. A stability management method based on the ratio of the total inclination for each loading stage compared to the whole inclination in the initial loading stage was also recommended.

  • PDF

전류변성기의 비오차와 위상오차의 절대 평가 기술 (Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers)

  • 김윤형;정재갑;한상길;구경완;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

개폐식 대공간 구조물의 지진 응답 제어 성능 향상을 위한 TMD의 최적 질량에 관한 연구 (A Study on Optimum Mass of TMD for Improving Seismic Response Control Performance of Retractable-Roof Spatial Structure)

  • 김동형;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.93-100
    • /
    • 2019
  • In this study, the retractable-roof spatial structure was chosen as the analytical model and a tuned mass damper (TMD) was installed in the analytical model in order to control the seismic response. The analysis model is mainly consisted of runway trusses (RT) and transverse trusses (TT), and the displacement response was analyzed by installing TMD on those trusses. The mass of the single TMD which is installed in the analytical model was set to 1% of the total structure mass and the total TMD mass ratio was set to be 8% or 6%. In addition, the mass of a single TMD was varied depending on the number of installations. As a result of analyzing the optimal number of installations of TMD, the displacement response was reduced in all cases compared to the case without TMD. Above all, the case with 8 TMDs was the most effective in reducing he displacement response. However, in this case, as the load on the upper structure of the retractable-roof spatial structure increases, the total mass ratio of TMD was maintained and the number of TMDs was increased to reduce the mass ratio of one TMD.

Seismic performance and design method of PRC coupling beam-hybrid coupled shear wall system

  • Tian, Jianbo;Wang, Youchun;Jian, Zheng;Li, Shen;Liu, Yunhe
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.83-96
    • /
    • 2019
  • The seismic behavior of PRC coupling beam-hybrid coupled shear wall system is analyzed by using the finite element software ABAQUS. The stress distribution of steel plate, reinforcing bar in coupling beam, reinforcing bar in slab and concrete is investigated. Meanwhile, the plastic hinges developing law of this hybrid coupled shear wall system is also studied. Further, the effect of coupling ratio, section dimensions of coupling beam, aspect ratio of single shear wall, total height of structure and the role of slab on the seismic behavior of the new structural system. A fitting formula of plate characteristic values for PRC coupling beams based on different displacement requirements is proposed through the experimental date regression analysis of PRC coupling beams at home and abroad. The seismic behavior control method for PRC coupling beam-hybrid coupled shear wall system is proposed based on the continuous connection method and through controlling the coupling ratio, the roof displacement, story drift angle of hybrid coupled shear wall system, displacement ductility of coupling beam.

강봉댐퍼의 단면형상과 형상비에 따른 변위의존성 및 성능 평가 (Displacement Dependency and Capacity Evaluation According to the Cross-Sectional Shape and Aspect Ratio of Steel Rod Dampers)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권5호
    • /
    • pp.89-96
    • /
    • 2023
  • 본 연구에서는 강봉댐퍼의 변위의존성 평가, 강도 및 에너지소산능력을 평가하였다. 실험 변수는 단면형상 및 형상비이며, 총 6개의 실험체를 제작하였다. 실험 결과, 설계기준에서 제시한 변위 의존성 조건을 모든 실험체가 만족하는 것으로 평가되었다. 그리고 단면형상에 따른 강도 영향은 미비하였다. 결과적으로, 형상비 13.7의 강도 및 에너지소산능력이 우수한 것으로 평가되었다.

사질토 지반에서 시멘트밀크 주입비에 따른 매입말뚝의 수평지지력 (The Lateral Load Capacity of Bored-Precast Pile Depending on Injecting Ratio of Cement Milk in Sand)

  • 홍원표;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.99-107
    • /
    • 2013
  • 매입말뚝의 수평저항 특성을 고찰하기 위하여 매입말뚝에 대한 수평재하시험을 실시하여 수평하중과 수평변위관계를 분석하였다. 말뚝수평재하시험은 시멘트 밀크가 말뚝매입길이의 50%, 70%, 100%로 주입된 6개의 말뚝에 대하여 실시하였다. 시멘트 밀크의 주입비(시멘트 밀크 주입길이/말뚝의 길이)는 매입말뚝의 수평변위, 항복하중, 수평지지력에 큰 영향을 미치는 것으로 나타났다. 시멘트 밀크의 주입비가 증가할수록 매입말뚝의 수평변위가 발생되기 시작하는 위치는 지표면에 가까워지며 말뚝의 수평변위는 감소한다. 그리고 말뚝의 수평지지력과 항복하중은 시멘트 밀크 주입비가 증가할 수록 크게 나타났다. 시멘트 밀크 주입비가 1인 매입말뚝의 항복하중과 극한수평지지력은 시멘트 밀크 주입비가 0.5인 경우보다 약 2~3배 정도 크게 나타났다.

비탄성변위비와 붕괴강도비를 이용한 MPA기반의 IDA 해석법 (MPA-based IDA Using the Inelastic Displacement ratio, CR and the Collapse Intensity, RC)

  • 한상환;석승욱;이태섭
    • 한국지진공학회논문집
    • /
    • 제14권5호
    • /
    • pp.33-39
    • /
    • 2010
  • 본 연구는 Modal Pushover Analysis(MPA)를 기반으로 비탄성 변위비(inelastic displacement ratio, $C_R$)와 붕괴 강도비(collapse strength ratio, $R_C$)를 이용한 간략한 Incremental Dynamic Analysis (IDA) 해석법을 제안해 냈다. 이 해석법은 선형 또는 비선형 동적해석 수행 없이 다자유도 시스템의 응답을 계산하기 때문에 간단하게 IDA곡선을 얻을 수 있다. 제안한 방법의 정확성은 6층, 9층, 20층의 철골 모멘트 골조를 대상으로 44개의 지진데이터를 사용하였으며 본 연구에서 제안하는 MPA를 이용한 $C_R-R_C$ IDA 해석결과와 비선형 동적해석 (Nonlinear Response History Analysis)을 통한 IDA 응답값, 그리고 각 주요모드의 비선형 동적해석을 통한 MPA-IDA 응답 값을 비교하여 타당성을 확인하였다. MPA를 이용한 $C_R-R_C$ IDA 해석법은 반복된 비선형 동적해석 과정이 없기 때문에 계산시 소요시간이 가장 작았으며 비교적 정확한 결과를 나타냈다.

휨 항복형 철근콘크리트 전단벽의 경계요소설계를 위한 변위연성비 모델제시 (Design Approach for Boundary Element of Flexure-Governed RC Slender Shear Walls Based on Displacement Ductility Ratio)

  • 문주현;양근혁
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.687-694
    • /
    • 2014
  • 이 연구에서는 철근콘크리트 전단벽의 경계요소의 연성설계를 위한 변위연성비모델을 제시하였다. 부재의 길이에 따른 곡률과 자유단에서의 변위를 산정하기 위한 전단벽의 단면의 변형률 및 내부힘들의 분포는 베르누이(Bernoulli)의 정리, 변형률 적합조건 및 힘의 평형조건을 이용하여 이상화하였다. 경계요소내의 횡보강근에 의한 구속효과는 Razvi and Saatcioglu에 의해 제시된 콘크리트의 응력-변형률 관계를 이용하여 고려하였다. 항복시 및 최대내력 이후 최대모멘트 80%에서의 곡률은 등가소성 힌지길이 개념을 도입하여 변위값으로 환산하였다. 일반화된 변위연성비의 모델은 다양한 범위에서 수행된 변수연구로부터 얻어진 데이터들의 회귀분석을 통하여 단순식으로 정립되었다. 제시된 단순모델은 실험결과 대비 평균, 표준편차 및 변동계수가 각각 1.05, 0.19 및 0.18로 대부분의 실험결과의 경향을 잘 예측하였다. 따라서 제시된 모델은 경계요소에서 소요연성비에 따른 횡보강근의 상세를 결정하는데 쉽게 이용될 수 있을 것으로 기대된다.

비탄성 이력응답 및 지진특성을 반영한 변위증폭계수에 관한 연구 (A Study of Displacement Amplification Factors Considering Hysteretic Behavior of Structural Systems and Earthquake Characteristics)

  • 송종걸;김학수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.777-782
    • /
    • 2007
  • Displacement amplification factor can be used to estimate inelastic displacement demands from elastic displacement demands, The simple formula for displacement amplification factor considering hysteretic behavior of structural system and earthquake characteristics is proposed. And the effects of several parameters such as displacement ductility, strain hardening ratio, period, characteristics of earthquakes and hysteretic models for the displacement amplification factor are evaluated. Accuracy of the proposed formula is evaluated by comparing the displacement amplification factors estimated by existing and proposed formula with those calculated from inelastic time history analysis. The displacement amplification factors by proposed formulas provide a good agreement with those calculated by inelastic time history analysis.

  • PDF