• 제목/요약/키워드: disk assessment

검색결과 47건 처리시간 0.027초

철도 차량용 제동디스크의 피로수명평가 (Fatigue Life Assessment for a Brake Disk of Railway Vehicles)

  • 석창성;박홍선;허용;김재훈;이영민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.385-386
    • /
    • 2006
  • A brake disk in railway vehicle is safety part. Requirements not only in performance but also in comfort, serviceability and working lifetime are high and rising. In this study, we carried out fatigue test and thermal stress analysis. To determine a pressure distribution, contact pressure analysis precede thermal stress analysis. Especially, characteristics of the brake disk were analyzed in considering intial velocity, and thickness of a frictional plate. Form the comparing the results of experiment and FEM analysis, fatigue characteristic and fatigue life assessment ok a brake disk of railway vehicle were performed.

  • PDF

제동 디스크 소재의 강도평가 (Strength Assessment of the Brake Disk material)

  • 이영민;최정훈;허용;박재실;석창성;최경진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.497-502
    • /
    • 2004
  • In this study, we compared the strength of a material used in the A-type disk brake with that in the B-type. From tensile test results, it has been found that the strength of the B-type disk brake is higher than that of the A-type. The microstructure observation and chemical analysis were conducted to determine the cause of the difference between the strength of A and B types of disk brake materials. From the experimental results, it has been confirmed that the difference in the strength between the two types of disk brake is due to the difference in the shape of graphite.

  • PDF

자기 공명 영상을 이용한 안면비대칭환자의 측두하악관절원반의 형태와 위치에 관한 연구 (Morphologic and positional assessment of temporomandibular joint disk in facial asymmetric patients by magnetic resonance imaging)

  • Zou, Bingshuang;Kim, Tae-Woo;Choi, Soon-Chul
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.398-407
    • /
    • 2005
  • 본 연구는 안면비대칭이 있는 환자의 측두하악관절원반 형태와 위치를 평가하고 악관절내장증과 안면비대칭 간의 관계를 규명하기 위하여 시행되었다. 남자 10명 및 여자 27명으로 구성된 안면비대칭 환자 37명의 74개의 TMJ MRI를 사용하였으며, 대상 집단의 연령은 12세에서 44세까지의 범위로 평균 21.4세였다. 시상 및 두정 TMJ MRI를 최대감합위 및 최대개구위에서 채득한 후 부분전방변위, 전방변위, 회전 또는 측방원반변위 등 원반변위의 종류를 기록하였으며, 원반의 모양위치, 그리고 원반의 변위 및 회전을 MRI tracing 상에서 판독하였다. 악관절내장증의 증상은 정상, 정복성 전방원반변위(ADDR), 그리고 비정복성 전방원반변위 (ADDNR) 집단으로 분류하였으며, 환자는 양측성 정상. 편측 혹은 양측 내장증 집단으로 분류하였다. 약$70\%$의 환자에서 편측성 또는 양측성 내장증을 보였으며. 통계분석 결과 ADD, 특히 회전성 ADD가 변위측에서 더 높은 빈도로 나타났으나 반대측에서는 원반의 위치가 정상인 경우가 많았다. (p<0.01). 변위측의 원반은 모양의 변형 및 하전방 변위를 유의하게 더 나타냈다. 그러나 반대쪽은 개구시 원반이 수직방향으로 과운동성이 관찰되었다. 이 연구는 안면비대칭 환자에서 ADD의 종류가 원반의 모양, 경사 변위 각도, 변위의 수직거리 및 회전각도와 연관이 있다는 것을 제시한다

Mixed mode fracture assessment of U-notched graphite Brazilian disk specimens by means of the local energy

  • Torabi, A.R.;Berto, F.
    • Structural Engineering and Mechanics
    • /
    • 제50권6호
    • /
    • pp.723-740
    • /
    • 2014
  • A fracture criterion based on the strain energy density (SED) over a control volume, which embraces the notch edge, is employed in the present paper to assess the fracture loads of some U-notched Brazilian disk (UNBD) specimens. The specimens are made of commercial graphite and have been tested under pure mode I, pure mode II and mixed mode I/II loading. The results show that the SED criterion allows to successfully assess the fracture loads of graphite specimens for different notch tip radii and various mode mixity conditions with discrepancies that fall inside the scatter band of ${\pm}20%$.

해머 단조된 Alloy 718 디스크의 결정립 분포 해석 (Assessment of Grain Size Distribution in a Hammer-Forged Alloy 718 Disk)

  • 염종택;박노광
    • 소성∙가공
    • /
    • 제6권3호
    • /
    • pp.250-256
    • /
    • 1997
  • Hammer forging was employed for Alloy 718 disk. The change in grain size during hot forging depends very much on dynamic recrystallization. The final grain size depends especially on the critical strain$($\varepsilon$_C)$/TEX> for dynamic recrystallization and Zener-Holloman parameter(Z). In this study, the critical strain$($\varepsilon$_C)$, the strain for 50 pct. recrystallization$($\varepsilon$_{0.5})$ and fraction of dynamic recrystallization(Xdyn) were measured by compression tests. FE simulation was also carried out ot predict the evolution of microstructure. The strain, strain rate and temperature distribution predicted by forging simulation can be effectively used to predict the distribution of grain sizes in the forged workpiece. The present model predictions showed an excellent agreement with the microstructural evolution of hammer-forged Alloy 718 disks.

  • PDF

Water carrying iron (iii) oxide (Fe3O4) ferrofluid flow and heat transfer due to deceleration of a rotating plate

  • Bhandari, Anupam
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.679-690
    • /
    • 2022
  • This research effort examines the flow behavior and heat transfer assessment of water carrying iron (iii) oxide magnetic fluid due to a rotating and moving plane lamina under the influence of magnetic dipole. The effect of rotational viscosity and magnetic body force is taken into consideration in the present study. The involvement of the moving disk makes a significant contribution to the velocity distribution and heat transfer in rotational flow. Vertical movement of the disk keeps the flow unsteady and the similarity transformation converts the governing equation of unsteady flow into nonlinear coupled differential equations. The non-dimensional equation in the present system is solved through the finite element procedure. Optimizing the use of physical parameters described in this flow, such results can be useful in the rotating machinery industries for heat transfer enhancement.

광기기 저장매체 구동용 BLDC 모터의 신뢰성 평가기준 (Reliability Assessment Criteria of Brushless Motor for Optical Disk Drive)

  • 송병석;천성일;정해성;백재욱
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권1호
    • /
    • pp.1-12
    • /
    • 2009
  • BLDC motors are stored in the devices such as CD-RW, COMBO, DVD-ROM and CD-ROM. It is indispensable to establish reliability assessment criteria for BLDC motors, especially in the world where IT grows rapidly. In this article, reliability certification procedure is given. The reliability certification procedure consists of two separate tests such as quality certification test and lifetime test. The former quality certification test comprises general performance test and environmental test. Items which pass the test undergo lifetime test which guarantees the extent of mean lifetime with certain confidence.

  • PDF

Visual Analogue Scale(VAS)을 이용한 동통평가표에 의한 동통관리의 효용성에 관한 연구 (A Study on Efficiency of Pain Management by Questionnaire using Visual Analogue Scale in Back - Pain Patients)

  • 이복희;윤홍일;박지환
    • 대한정형도수물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.105-112
    • /
    • 1995
  • This study was designed to investigate the efficiency of subjective assessment that exams the subjective symptom of patients with back pain at the department of physical therapy. To assess the subjective symptom, we used the pain questionnaire using visual analogue scale (VAS) that was developed by Wang on 1995. Questionnaires were administered to 31 adult patients(male : 11, female : 20) with herniated lumbar disk(13), low back pain(8), myofascial pain syndrom(5), lumbar strain(4), ankylosing spondylitis(1). Mean age was 36.3 ranged from 20 to 65. The results of this study were as follows : 1) In each of 15 subjects, there was a significant decrease in VAS between pre- and post-treatment(p<0.05). 2) Mean VAS of total subjects was $6.26{\pm}2.55$ in pre-treatment, $4.50{\pm}2.47$ in post-treatment (p<0.001). Result of this study was shown efficiency of pain management by subjective assessment. The continuous study is needed for many interesting illue of pain management using VAS.

  • PDF

VAS를 이용한 동통평가표에 의한 동통관리의 효용성에 관한 연구 (A Study on Efficiency of Pain Management by Questionnaire using Visual Analogue Scale in Back- Pain Patients)

  • 이복희;윤홍일;박지환
    • 대한물리치료과학회지
    • /
    • 제2권3호
    • /
    • pp.679-689
    • /
    • 1995
  • This study was designed to investigate the efficiency of subjective assessment that exams the subjective symptom of patients with back pain at the department of physical therapy. To assess the subjective symptom, we used the pain questionnaire using visual analogue scale(VAS) that was developed by Wang on 1995. Questionnaires were administered to 31 adult patients(male : 11, female: 20) with herniated lumbar disk(13), low back pain(8), myofascial pain syndrom(5), lumbar strain(4), ankylosing spondylitis(1). Mean age was 36.3 ranged from 28 to 65. The results of this study were as follows: 1) In each of 15 subjects, there was a significant decrease in VAS between pre-and post-treatment(p < 0.05 -p<0.001). 2) Mean VAS of total subjects was $6.26{\pm}2.55$ in pre-treatment, $4.50{\pm}2.47$ in post-treatment(p < 0.001). The result of this study was shown efficiency of pain management by subjective assessment. The continuous study is needed for many interesting issue of pain management using VAS.

  • PDF

비접촉 초음파 탐상 기법을 이용한 항공기 브레이크 디스크의 신뢰성 평가 (Reliability Evaluation of Aircraft Brake Disk using the Non-contact Air-coupled Ultrasonic Transducer Method)

  • 곽남수;김재열;고가진;박대광
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.36-43
    • /
    • 2016
  • Carbon fiber-reinforced silicon carbide (Cf-SiC) and SiC / SiC composites have high thermal conductivity, and excellent corrosion and wear resistance, a low coefficient for thermal expansion and are lightweight. This is why they are commonly used in parts of the aerospace industry to develop an aircraft thrust deflector, jet vane, combustion chamber, elevens, body flap, and a shingle. So, understanding how this state-of-the-art Cf-SiC affects both internal and external crack detection and determining issues during the manufacturing process of composite materials, should be evaluated according to valuation techniques in the external environment. In this paper, we apply a non-contact air ultrasonic technique of non-destructive testing techniques to perform a study on internal defect detection identification and assessment of carbon-fiber reinforced silicon carbide composites to perform basic research and applied research.