• 제목/요약/키워드: disconnector

검색결과 23건 처리시간 0.033초

측정 위치에 따른 GIS에서 VFTO 상승률 분석 (Analysis of Rate-of-rise of VFTO in GIS according to Measurement Point)

  • 오윤식;서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.519-520
    • /
    • 2011
  • In Gas Insulated Substation(GIS), Very Fast Transient Overvoltages(VFTOs) are generated by the switching operation of disconnector or circuit breaker and it is propagated to each component of GIS. Each component of GIS is modeled by lumped line model and distributed line model based on equivalent circuits. The various cases which can be operated and the various closing point-on-wave are considered. In this paper, magnitude and rate-of-rise of VFTO are simulated and analyzed by comparing the simulation results. Measurements are performed at transformer and circuit breaker.

  • PDF

170kV급 단로기용 Composite Insulator 설계 및 특성 연구 (A Study Performance and Design Compositor Insulator for 170kV D/S)

  • 조한구;박기호;한동희;윤문수;진상용;송희석;이동원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.252-254
    • /
    • 2003
  • Recently composite insulators are being used for outdoor high voltage applications. Composite insulators for transmission line have significant advantages over porcelain insulators, especially for ultra-high voltage. Their advantages are light weight, vandalism resistance, and hydrophobicity. We developed a 170kV high reliable vertical break disconnector with good long term electrical and mechanical performance which was achieved by the improvement of electrical performance and light weight. We discuss the outline of the development and the product.

  • PDF

Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV

  • Seo, Hun-Chul;Jang, Won-Hyeok;Kim, Chul-Hwan;Chung, Young-Hwan;Lee, Dong-Su;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.11-19
    • /
    • 2013
  • Very Fast Transients (VFT) originate mainly from disconnector switching operations in Gas Insulated Substations (GIS). In order to determine the rate-of-rise of Very Fast Transient Overvoltage (VFTO) in a 550 kV GIS, simulations are carried out using EMTP-RV. Each component of the GIS is modeled by distributed line model and lumped model based on equivalent circuits. The various switching conditions according to closing point-on-wave and trapped charge are simulated, and the results are analyzed. Also, the analysis of travelling wave using a lattice diagram is conducted to verify the simulation results.

태양광 발전용 단상 30kW급 직류누전차단기 개발 (Development of DC Leakage Disconnector for Solar Power Generation System)

  • 한후석;조성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1567-1568
    • /
    • 2015
  • 태양광 발전시스템에서 발생되는 누설전류에 인하여 누전화재와 인체감전 등의 전기재해를 방지하기 위해서 직류누전차단기를 개발하였다. 직류누설전류를 측정할 수 있는 센서를 개발하여 (+)전선로와 (-)전선로에 흐르는 누설전류를 각각 검출하는 방법을 제안하였다. 제안된 방법과 개발된 센서를 이용하여 시작품을 제작하고 센서에 대한 감도전류 특성시험을 수행하였다. 또한 인버터가 포함되어 있는 태양광 발전시스템에 적용하여 실제 나타나는 직류누설전류를 측정하는 시험을 수행하였다. 그 결과 직류누설전류센서의 정확성을 확인하였으며, 전선로에 흐르는 직류 및 교류성분의 누설전류를 ${\pm}5%$ 범위 내에서 측정함을 확인하였다. 개발된 센서를 적용한 태양광 발전용 직류누전차단기를 제작하였다.

  • PDF

신경회로망을 이용한 부분방전 신호의 패턴분석 (The Analysis of PD Signal using Neural Network)

  • 김종서;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.567-571
    • /
    • 2004
  • Recently, GIS(Gas Insulated Switchgear) has been recognizing of importance on development of diagnosis technique which is happened problem on confidence for a long time use. Therefore, the measurement and analysis of PD with prior phenomenon of insulation breakdown is used many method of diagnosis for GIS. In this paper, we simulate trouble condition in DS and analysis trouble signal to use electrical and mechanical methods, interpretation of detected signal has analysed with to use ø-q-n pattern and neural network. For this analysis, we have used the induction and AE(acoustic emission) sensors. For the simulation experiment, we make DS for 170 KV GIS and analyze the classification and characteristics of detected signals with the application of neural network algorithm.

복합 가속열화를 통한 배전용 고분자 피뢰기의 장기 열화특성 예측 (Longterm Aging Characteristics of Distribution Polymer Housed Surge Arresters by Multistress Accelerated Aging)

  • 김주용;권태호;박철배;김준일
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.691-696
    • /
    • 2007
  • In this study accelerated aging test equipment was developed to simulate domestic weather condition for accelerated aging test of polymer housed distribution surge arresters. Polymer arresters were aged for 3,000 hours by this test equipment and chemical and electrical characteristics analysis of surge arresters were conducted after aging test. In addition, performance assessment of outdoor installed arresters for 3 years was conducted to compare aging effect between accelerated aging test and natural aging. Through this experiment it is verified that the capability of the proposed aging test for simulating natural aging and the housing material and disconnector of domestic polymer arresters can be deteriorated by the long time field operation.

MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구 (Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices)

  • 심해섭;전태현
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.71-77
    • /
    • 2010
  • 뇌서지 보호는 오늘날 대부분의 전기전자기기에 있어 중요한 문제 중 하나이다. 그리고 뇌서지 보호를 위한 대다수 SPD의 가장 주요 부품으로 MOV가 사용된다. 본 논문에서는 다양한 타입의 MOV 기반 SPD를 조사하고 낮은 MLV특성의 부작용에 대하여 실험하였다. 실험결과로서 상대적으로 낮은 MLV특성은 실제 현장에서 발생 가능한 TOV 고장 상태하에서 더 큰 고장률로 나타날 수 있으며, 피보호기기보다 우선하여 소손될 수 있음을 알 수 있다. 결국 안전면에서 SPD는 높은 TOV내력과 신속한 단로기의 동작이 요구된다.

주택화재시 지붕위에 설치된 태양광 시스템의 위험성에 관한 연구 (A Study on the Risks of Solar Photovoltaic Systems Installed on the Rooftop in a Domestic Fire)

  • 권성필;한용택;임우섭;김대희;김진선
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.464-467
    • /
    • 2012
  • 본 연구에서는 최근 신재생에너지원으로서 가장 널리 사용되고 있는 태양광 시스템에 대하여 화재발생시 야기될 수 있는 위험성뿐만 아니라 화재진압 과정에서 발생할 수 있는 문제들을 다루었다. 특히 주택의 지붕위에 설치된 실리콘이 주성분인 태양광 패널은 화재가 발생할 경우 생성되는 열을 차단 및 반사하여 건물 내에 축적시킴으로써 화재강도를 직접적으로 증가시킬 수 있으므로 설치 시 이러한 위험성에 대비할 수 있는 방안을 마련해야 한다. 또한 PV 시스템에 연결된 고압 전력선에 물을 뿌릴 경우 소방대원들의 감전으로 인한 부상이나 사망으로 이어질 수 있으므로, 이를 방지하기 위한 대책마련이 시급한 것으로 나타났다. 해외에서는 현재 전력전자 소자가 내장되어 있는 DC 차단스위치 및 모듈이 판매되고 있는 것으로 조사되었다.

  • PDF

Capacitive Coupling을 이용한 VFTO 측정계에 대한 고찰 (On the Considerations of VFTO Measuring Systems using by Capacitive Coupling)

  • 김진기;김민규;김영배;문인옥;김익수;이형호;김종연;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1520-1522
    • /
    • 1994
  • The clarification of insulation capability of GIS(Gas Insulated Substation) under very fast transient overvoltages such as disconnector/circuit-breaker induced surge is very important for establishing not only a rational insulation testing method, but also insulation design intending to make GIS more reliable and more minimized. One of the absolute prerequisits for this is that more accurate measurement of VFTO. This describes capacitive voltage measuring methods for high voltage steep-footed oscillating waves using capacitive coupling principle and their systems including source and load impedances. Time domain response of unit step and its frequency characteristics are also investigated.

  • PDF

GIS내에서 금속이물이 절연파괴에 미치는 영향 (The Effect of Conducting Particles on Breakdown Phenomena in GIS)

  • 김민규;문인옥;김윤택;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1574-1576
    • /
    • 1994
  • $SF_6$ gas has become an important insulation medium in modern electric power apparatus, because of its high insulation withstand levels and good arc quenching capability. For the application of $SF_6$ gas in GIS the estimation of insulation properties is a fundamental point. Moreover the reduction of withstand levels in case of inhomogeneous fields caused by particles or fixed protrusions is of special interest. It is known that the presence of free conducting particles in GIS can significantly lower the insulating level of $SF_6$ gas at elevated pressure and also it has been recently shown that dielectric strength is greatly reduced by fast transients such as disconnector surges where metallic particles are involved. In this paper, we have disigned the particle test chamber rated 362kV for the purpose of investigating the discharge characteristics in SF6 gas where inhomogenius fields are caused by metallic particles.

  • PDF