The Tools Development for Electric Shock Accident Prevention at Electric Construction Work (전기공사 작업시 감전사고 방지용 공구류 개발)

  • Lee, H.K.;Kim, H.J.;Baek, S.H.;Won, S.H.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.43-45
    • /
    • 2005
  • Electric accidents, like getting electrified, sometimes happen to people working on electricity. A highly probable reason why these electric accidents happen is that workers are used to skip confirming disconnection of electricity when they work. It is mostly because they have little understanding of electricity. To overcome this, various applications such as 'electric detecting stick' are invented to check existence of electricity on working environment. But, they have not been popular due to inconvenience of carrying. So, we made a new instrument. It is a kind of nipper on which electric detecter is installed. Detecting existence of electricity is less burdensome via this tool we made.

  • PDF

The Tools Development for Electric Shock Accident Prevention at Electric Construction Work (전기공사 작업시 감전사고 방지용 공구류 개발)

  • Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.158-160
    • /
    • 2005
  • Electric accidents, like getting electrified, sometimes happen to people working on electricity. A highly probable reason why these electric accidents happen is that workers are used to skip confirming disconnection of electricity when they work. It is mostly because they have little understanding of electricity. To overcome this, various applications such as I electric detecting stick' are invented to check existence of electricity on working environment. But, they have not been popular due to inconvenience of carrying. So, we made a new instrument. It is a kind of nipper on which electric detecter is installed. Detecting existence of electricity is less burdensome via this tool we made.

  • PDF

Interfacial Properties and Curing Behavior of Carbon Fiber/Epoxy Composites using Micromechanical Techniques and Electrical Resistivity Measurement (Micromechanical 시험법과 전기적 고유저항 측정을 이용한 탄소섬유강화복합재료의 계면 물성과 경화거동에 관한 연구)

  • 이상일;박종만
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.17-21
    • /
    • 2000
  • Logarithmic electrical resistivity of the untreated or thin diameter carbon fiber composite increased suddenly to the infinity when the fiber fracture occurred by tensile electro-micromechanical test, whereas that of the ED or thick fiber composite increased relatively broadly up to the infinity. Electrical resistance of single-carbon fiber composite increased suddenly due to electrical disconnection by the fiber fracture in tensile electro-micromechanical test, whereas that of SFC increased stepwise due to the occurrence of the partial electrical contact with increasing the buckling or overlapping in compressive test. Electrical resistivity measurement can be very useful technique to evaluate interfacial properties and to monitor curing behavior of single-carbon fiber/epoxy composite under tensile/compressive loading.

  • PDF

An Energy-Efficient Mobility-Supporting MAC Protocol in Wireless Sensor Networks

  • Peng, Fei;Cui, Meng
    • Journal of Communications and Networks
    • /
    • v.17 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • Although mobile applications are an essential characteristic of wireless sensor networks, most existing media access control (MAC) protocols focus primarily on static networks. In these protocols, fixed periodic neighbor discovery and schedule updating are used to connect and synchronize neighbors to provide successful data transmission; however, they cannot adapt to mobile speed variation and degrade the network performance dramatically. In this paper, we propose a mobile-supporting mechanism for MAC protocols, in which the decision to update the neighbors of a mobile node is made adaptively according to the mobile speed. Analysis and simulation results demonstrate that the mechanism efficiently avoids the disconnection of amobile node from its neighbors and achieves a better performance as compared with fixed periodic neighbor discovery.

An efficient Step-parents Node selection Technique in MANET (MANET에서 에너지 효율적인 양부 노드의 선택 방법)

  • Lee, Jong-Seung;Lee, Kang-Whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.855-857
    • /
    • 2011
  • In this paper, we proposed EEAR(Efficient Energy Alternative Routing). This is a method of selecting a backup node for path routing management. When some node disconnection on the path routing, using pre-selected backup node provides immediately recover the path recovery. When selecting a Step-Parents node on the path management, the node' s energy level and distance information are cared in context-awareness. This not only increased the system' s capacity cost effectively, but also reduce transmission power entire nodes consume energy. As a result, each node could efficiently management and improves the life time for mobile host and extends system coverage.

  • PDF

A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305 (국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구)

  • Lee, Kang-Hee;Lee, Sang-Hyup;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

Implementation of Mobile Cliented-Server System for Real-Time Processing (실시간 처리 기반의 모바일 클라이언트-서버 시스템 구현)

  • Joo, Hae-Jong;Hong, Bong-Wha
    • The Journal of Information Technology
    • /
    • v.9 no.4
    • /
    • pp.35-47
    • /
    • 2006
  • Many researches are going on with regard to issues and problems related to mobile database systems, which are caused by the weak connectivity of wireless networks, the mobility and the portability of mobile clients. Mobile computing satisfies user's demands for convenience and performance to use information at any time and in any place, but it has many problems to be solved in the aspect of data management. The purpose of our study is to Implement Real-Time Mobile Query Processing System(MQPS) to solve problems related to database hoarding, the maintenance of shared dataconsistency and the optimization of logging, which are caused by the weak connectivity and disconnection of wireless networks inherent in mobile database systems under mobile client server environments. In addition, we proved the superiority of the proposed MQPS by comparing its performance to the C I S(Client-Intercept-Srever) model.

  • PDF

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

A Study on the Safety of Medical IT System connecting Medical Insulation Transformer in Medical Locations (의료용 절연변압기에 연결하는 의료 IT시스템의 안전에 관한 연구)

  • Kim, Se-Dong;Kim, Eun-Sik;Park, Jung-Il;Choi, Hyung-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.61-66
    • /
    • 2011
  • An accidental disconnection of power supply for operating theatres may result in fatal accidents. Thus, it is necessary to import the electric safety system in medical locations. This paper shows an analysis of simulation for the safety in medical IT system based on KS C IEC 60364-7-710(Electrical Installations of Buildings - Requirements for special installations or locations - Medical locations). The analysis was progressed by measuring leakage currents according to variation of volts, circuits and loads. And it was made database for calculation the reasonable length of branch circuit.

A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults (접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul;Lee, Bong-Seob;Park, Young-Jic
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.