• 제목/요약/키워드: discharge signal

검색결과 409건 처리시간 0.029초

속이 빈 원통형음극 방전의 전압-전류 곡선에서 음 저항 영역 관찰 (Observation of Negative Resistance Region in Voltage-current Curve of Hollow Cathode Discharge)

  • 이준회;이성직
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.870-875
    • /
    • 2005
  • We measured the optogalvanic signal and discharge voltage-current(V-I) curve under the two different discharge conditions with different buffer gases, Ar, and Ne. When the Gd was used as a cathode material at low discharge current less than 10mA, a significant change was observed in the current-voltage curve. Time resolved optogalvanic signal measurement were measured by the diode laser of which wavelengths correspond to metastable transition line of these gases (Ar, Ne). From these measurements, we found that the characteristics of the V-I curve strongly depend on the Penning ionization process.

고압권선에서 발생하는 부분방전에 의한 초음파 신호 검출 (Detection of Ultrasonic Signals by PD at the High Voltage Winding)

  • 권동진;곽희로;정상진;김한상;송일근;김경화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.456-458
    • /
    • 1995
  • This paper describes a diagnosis of power transformers by on-line detection of ultrasonic signals. Partial discharge in power transformer generates ultrasonic signals. The trend of the ultrasonic signal number can be measured when partial discharge is generated in HV Winding. The trend of the ultrasonic signal number could easily be distinguished by taking moving average. The insulation failure due to partial discharge in transformers can be predicted based in the trend analysis of the number of ultrasonic signals caused by partial discharge.

  • PDF

변압기내 결함의 종류에 따른 부분방전의 초음파신호 특성 분석 (Characteristics of Ultrasonic Signal by Defect types in the Transformer)

  • 박현수;진상범;곽희로;권동진;박하용
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.296-298
    • /
    • 1999
  • Out of the defects occurred in a transformer, the cases of protrusion and surface discharge were simulated by using needle-plane and IEC(B) electrode. The waveform and frequency characteristics of ultrasonic signals due to partial discharge occurred at each electrode were analyzed. And then, the ultrasonic signal characteristics from the partial discharge due to the two kinds of defect were compared. As a result, in the case of the protrusion and surface discharge, the waveforms were similar, but the frequency spectra were different.

  • PDF

부분방전원에 따른 초음파신호 특성분석 (Acoustic Signal Analysis to Discriminate Partial Discharge Sources)

  • 이용희;박성희;이강원;이용희;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1691-1693
    • /
    • 2002
  • Acoustic partial discharge detection has been used on GIS testing for more than 10 years. Sensitivities show that most of critical defect types can be detected with a reasonable signal-to-noise ratio. The paper reports on acoustic partial discharge detection comparable to sensitive electrical PD(partial discharge) measuring method.

  • PDF

부분방전 신호의 비 선형적 해석 (A Nonlinear Analysis of The Partial Discharge Signal)

  • 김성홍;임윤석;장진강;이영상;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.165-168
    • /
    • 1999
  • The chaotic characteristics of partial discharge(PD), may seems to be stochastic and merely random, were investigated using the method to discern between chaos and random signal, e.g. correlation integral, Lyapunov characteristic exponents and etc. For the purpose of obtaining experimental data, computer aided partial discharge detecting system was used. While this method is very different from typical statistical analysis from the point of view of a nonlinear analysis, it can provide better interpretable criterion according to the time evolution with a degradation process in the same type insulating system.

  • PDF

통계처리와 패턴 인식 기법에 의한 부분방전 해석 (Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique)

  • 변두균;홍진웅
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

웨이브렛 변환을 이용한 GIS의 부분방전 검출 알고리즘에 관한 연구 (A Study on the Algorithm for Detection of Partial Discharge in G15 Using Wavelet Transform)

  • 강진수;김철환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.25-34
    • /
    • 2003
  • Gas insulated switchgear(GIS) is an important equipment in a substation. It is highly desirable to measure a partial discharge(PD) in GIS which is a symptom before insulation breakdown occurs. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the algorithm for detection of PD in GIS using wavelet transform is proposed. The wavelet transform provides a direct quantitative measure of spectral content, "dynamic spectrum", in the time-frequency domain. The recommended mother wavelet is 'Daubechies' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. Through the procedure of wavelet transform, noise extraction and reconstruction, the signal is Analyzed to determine the magnitude of PD in GIS. In experimental results, we can know that partial discharge is exactly detected in combination of Dl and D2 using wavelet transform.transform.

고압전동기 고정자권선의 부분방전 특징추출 (Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor)

  • 박재준
    • 정보학연구
    • /
    • 제7권4호
    • /
    • pp.61-69
    • /
    • 2004
  • 본 논문에서는 6.6kV급 고압전동기 모델 코일을 4가지의 권선의 인공적인 결함을 갖도록 제작하였다. 운전중 모의를 위해 모델 코일에 80pF의 에폭시-마이카 커플러를 설치하였으며, TGA를 사용하여 NQN, 부분방전 크기 및 부분방전 패턴 등을 측정하였다. 웨이블렛 변환기법을 이용한 고압전동기의 고정자권선의 결함에서 발생된 부분방전신호의 파형을 통하여 여러 가지의 통계적인 파라메터를 통하여 특징을 추출하였다.

  • PDF

원격감시 기능을 갖는 고감도 부분방전센서 (Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities)

  • 최규남
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.349-356
    • /
    • 2015
  • 광학적 잡음과 전기적 잡음을 복합적으로 제거할 수 있는 하이브리드 필터를 채용하고 펄스형태의 아크 광 신호를 적분하여 수신되는 아크에너지의 크기로 감지할 수 있는 원격감시 기능을 갖는 고감도 부분방전 센서를 구현하였다. 하이브리드 필터는 부분방전 센서가 설치되는 배전반 내 환경에서 내부 형광등과 백열등 조명에 대하여 영향을 받지 않음을 보여주었다. 종래에는 아크광의 불규칙한 파형특성으로 인하여 첨두치가 감지되어 아크광의 크기에 비례한 선택적 감지가 어려웠으나, 센서에 적용된 적분연산 기능은 각기 다른 아크광의 에너지 레벨에 대하여도 선택적으로 감지가 가능함을 실험적으로 보여주었다. 센서는 2m 이격된 원격지에서 100A 저압 MCCB의 정상 개폐 시 발생하는 섬광에 해당하는 광 에너지에 대해서도 감지가 가능함을 보여주어 원격감시 기능을 갖는 고감도 부분방전센서에 적용 가능함을 보여주었다.

다중해상도 분해에 의한 부분방전 신호의 특징에 관한 연구 (A Study on the Characteristics of Partial Discharge Signal by Multiresolution Decomposition)

  • 이현동;김충년;이광식;이동인;최상태;이동헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1924-1926
    • /
    • 2000
  • This paper deals with the multiresolution analysis of wavelet transform for partial discharge(PD).PD is an electrical discharge that only partically bridges the insulation performance of electrical equipment in high voltage. PD signal is very sensitive and difficult to suppress strong noises such as narrow-band radio frequency noise and random noise. In recently, wavelet transform has become a powerful tool to analysis and process signals in various science and technology fields. In this paper, daubechies family is adopted for the research of the characteristics of PD signals. The results show that the kurtosis is increased with discharge process and skewness is decreased with discharge process, but when PD occured positive range then skewness is increased. Segment 7, 8, 9, 10, 11 values is increased with discharge process, so phase distribution is characterized by 210$\sim$330 ranges.

  • PDF