PD measuring on MV XLPE Calble by Using UWB Antenna (UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Lee, Yong-Sung;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

Application of AI-foil Electrode for Detecting Partial Discharge in Middle Joint Box (초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극 응용)

  • Kim, Dae-Yeol;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.79-81
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun;Kim, Hee-Dong;Lee, Dong-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.112-116
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet transform coefficients.

  • PDF

PD Measurement and Pattern Discrimination of Stator Coil for Traction Motor according to Different Defects (결함에 따른 견인전동기 고정자 코일의 부분방전측정 및 패턴분류)

  • Jang, Dong-Uk;Park, Hyun-June;Park, Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.221-222
    • /
    • 2005
  • In this paper, application of NN (Neural Network) as a method of pattern discrimination of PD(partial discharge) which occurs at the stator coil of traction motor was studied. For PD data acquisition, three defective models are manufactured such as internal discharge model, slot discharge model and surface discharge model. PD data for recognition were acquired from PD detector and DAQ board which is able to analysis the PD signal and perform the pattern discrimination. Statistical distributions and parameters are calculated to discriminate PD sources. And also these statistical distribution parameters are applied to classify PD sources by BP and has good recognition rate on the discharge sources.

  • PDF

Electric Fire Prediction by Detection of Discharge Signal (방전신호 검출에 의한 전기화재 예측)

  • 길경석;송재용;권장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.413-419
    • /
    • 2004
  • This paper describes a technique that can predict electric fires by detection of discharge voltage signals caused by the use of electric facilities. In the experiment, various discharge modes, a flashover or a surface discharge through insulation paper and a line to line short, were simulated to acquire electrical information for predicting electrical fire as discharge modes. From the experimental results, it is hewn that electorial discharges which are ranked as majority causes of electric fires generate characterized signals distinguished from power frequency. Finally. We designed a prototype discharge detector based on the experimental results, and the detector is applied to a power lines. This study showed that the prediction of electric fires is possible by monitoring discharge voltage signals in electric power lines.

A study on the UHF signal Characteristics by two kinds of PD in GIS (GIS내 PD 종류에 따른 UHF신호의 특성연구)

  • 송현석;이재화;장덕근;이동준;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.251-255
    • /
    • 2002
  • This paper describes the analysis of UHF signals taking place at partial discharges due to defects in GIS. To imitate the defects, two kinds of electrode were employed. One is to generate the PD due to corona discharge, and the other surface discharge. As a result, the magnitude of the UHF signals acquired from the discharges increased with the applied voltage. However, each frequency distribution trend at corona discharges and surface discharge was similar even though the applied voltage increased. Frequency distribution between corona discharge and surface discharge was clearly distinguish.

  • PDF

Observation of spontaneous oscillation of optogalvanic signal in a hollow cathode discharge (Hollow cathode discharge에서 자발적 진동의 광검류 신호 측정)

  • 이준회
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.51-54
    • /
    • 2003
  • The spontaneous oscillations in the optogalvanic signals are observed in negative glow region of Ar hollow cathode discharge. The spontaneous oscillations in the optogalvanic signals are observed at low discharge currents less than about 3 mA. Based on the simultaneous measurements of both the density variation of metastable atoms and emission intensities of the 1s-2p transitions, one of the possible mechanisms for the spontaneous oscillation is considered to be related to the stepwise ionization of the metastable atoms due to collisions with slow electrons in the discharge.

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Analysis of Electrical discharge signal according to particle state in GIS (GIS내 파티클의 상태에 따른 전기적 방전 신호 분석)

  • Lee, Dong-Zoon;Lee, Gon;Kwak, Hee-Ro;Kim, Kyung-Wha;Kwon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1084-1086
    • /
    • 1999
  • The breakdown was caused by particle in GIS and various methode was suggested to find particle in GIS. In this paper, four states of particle was imitated which are particle on electrode, particle on enclosure, particle on spacer and crossing particle. The discharge voltage of each states was classified by four voltages which are initial, development, later and close discharge voltage. $\Phi$-Q-N pattern was analyzed according to the states and to the discharge voltages. In the result, the electrical discharge pattern according to the particle states may be distinguished.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF