• Title/Summary/Keyword: discharge flow

Search Result 2,053, Processing Time 0.032 seconds

Development of Pore-filled Ion-exchange Membranes for Efficient All Vanadium Redox Flow Batteries

  • Kang, Moon-Sung
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.204-210
    • /
    • 2013
  • Thin pore-filled cation and anion-exchange membranes (PFCEM and PFAEMs, $t_m=25-30{\mu}m$) were prepared using a porous polymeric substrate for efficient all-vanadium redox flow battery (VRB). The electrochemical and charge-discharge performances of the membranes have been systematically investigated and compared with those of commercially available ion-exchange membranes. The pore-filled membranes were shown to have higher permselectivity as well as lower electrical resistances than those of the commercial membranes. In addition, the VRBs employing the pore-filled membranes exhibited the respectable charge-discharge performances, showing the energy efficiencies (EE) of 82.4% and 84.9% for the PFCEM and PFAEM, respectively (cf. EE = 87.2% for Nafion 1135). The results demonstrated that the pore-filled ion-exchange membranes could be successfully used in VRBs as an efficient separator by replacing expensive Nafion membrane.

Form Drag Factor of Contracted Flow (축소단면흐름 형상항력계수)

  • 권순국;유동훈
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.3_4
    • /
    • pp.82-89
    • /
    • 1995
  • The efforts of formulation have been reviewed and the results of existing laboratory experiments are investigated in order to describe the contracted flow which occurs at the final closure of sea dike construction. The regional characteristics of contracted flow is analyzed by checking the drawdown curve, and Chezy's mean velocity equation is employed to estimate the discharge rate at the closure. Weir-type discharge equations are reviewed, which are derived from Bernoulli equation, and the problems of the equations are discussed. Chezy's mean velocity equation is considered to be widely and generally applicable, and the empirical factor introduced in Chezy's equation is named 'form drag factor' since it is primarily dependent on the form drag caused by the contraction of discharge area. Laboratory experiments were conducted mainly in order to investigate the variation of form drag factor against various parameters, and an empirical equation is developed for the estimation of form drag factor.

  • PDF

Analysis of the Thrust Augmentation in the Canister with Baseplate Orifices (오리피스 형상에 따른 발사관 내 부가추력 특성 연구)

  • Yoon, Jin-Young;Lim, Beom-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1067-1072
    • /
    • 2011
  • If the flow of booster gas which is exhausted to the rear part of a canister is properly restricted in the canister of a hot-launch system, the resultant pressure built up in the canister provides additional force to accelerate the missile to a required launch velocity. These thrust augmentation performances can be controlled through the configuration design of baseplate orifices. In this paper, the simple technique to analyze the thrust augmentation performances of baseplate orifices is suggested and the thrust augmentation characteristics by its various configurations are compared. According to the initial displacement of a missile, the inner pressure of a canister is measured from scaled cold flow tests, and the discharge coefficient of baseplate orifices is calculated. Then the thrust augmentation in a canister is simulated by applying these discharge characteristics to the AMESIM software for launch dynamics.

Quantification of Realistic Discharge Coefficients for the Critical Flow Model of RELAP5/MOD3/KAERl (RELAP5 / MOD3/ KAERI의 임계유동모델을 위한 실제적 배출계수의 정량화)

  • Kwon, T.S.;Chung, B.D.;Lee, W.J.;Lee, N.H.;Huh, J.Y.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.701-709
    • /
    • 1995
  • The realistic discharge coefficient for the critical How model of RELAP5/AOD3/KAERI are determined for the subcooled and too-phase critical flow by assessments of nine MARVIKEN Critical flew Test(CFT). The selected test runs include a high initial subcooling and large nozzle aspect rat-io(L/D). The code assessment results show that RELAP5/MOD3/KAERI over-predicts the subcooled critical flow and under-predicts the two-phase critical flow. Using these result, the realistic discharge coefficients of critical flow models are quantified by an iterative method. The realistic discharge coefficients are determined to be 0.89 for the subcooled critical How and 1.07 for the two-phase critical flow, and the associated standard deviations are 0.0349 and 0.1189, respectively. The results obtained from this study can be applied to calculate the realistic system response of Large Break Loss of Coolant Accident and to evaluate the realistic Emergency Core Cooling System performance.

  • PDF

Development on Prediction Algorithm of Sediment Discharge by Debris Flow for Decision of Location and Scale of the Check Dam (사방댐 위치 및 규모 결정을 위한 토석류 토사유출량 예측 알고리즘 개발)

  • Kim, Kidae;Woo, Choongshik;Lee, Changwoo;Seo, Junpyo;Kang, Minjeng
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.586-593
    • /
    • 2020
  • Purpose: This study aims to develop an algorithm for predicting sediment discharge by debris flow, and develop GIS-based decision support system for optimal arrangement of check dam. Method: The average stream width and flow length were used to predict the cumulative sediment discharge by debris flow. At this time, the amount of slope failure on source area and average flow length were utilized as input factors. Result: The predicted sediment discharge calculated through the algorithm was 1.1 times different on average compared to the actual sediment discharge by debris flow. In addition, the program is an objective indicator that selects the location and size of the check dam, and it can help practitioners make rational decisions. Conclusion: The soil erosion control works are being implemented every year. Therefore, it is expected that the GIS-based decision support system for location and size of the check dam will contribute to the prevention of sediment-related disasters.

Study on the Critical Nozzle Flow of Hydrogen Gas with Real Gas Effects (실제기체 효과를 고려한 수소기체의 임계노즐 유동에 관한 연구)

  • Kim, Jae-Hyung;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3003-3008
    • /
    • 2007
  • Critical nozzle has been frequently employed to measure the flow rate of various gases, but hydrogen gas, especially being at high-pressure condition, was not nearly dealt with the critical nozzle due to treatment danger. According to a few experimental data obtained recently, it was reported that the discharge coefficient of hydrogen gas through the critical nozzle exceeds unity in a specific range of Reynolds number. No detailed explanation on such an unreasonable value was made, but it was vaguely inferred as real gas effects. For the purpose of practical use of high-pressure hydrogen gas, systematic research is required to clarify the critical nozzle flow of high-pressure hydrogen gas. In the present study, a computational fluid dynamics(CFD) method has been applied to predict the critical nozzle flow of high-pressure hydrogen gas. Redlich-Kwong equation of state that take account for the forces and volume of molecules of hydrogen gas were incorporated into the axisymmetric, compressible Navier-Stokes equations. A fully implicit finite volume scheme was used to numerically solve the governing equations. The computational results were validated with some experimental data available. The results show that the coefficient of discharge coefficient is mainly influenced by the compressibility factor and the specific heat ratio, which appear more remarkable as the inlet total pressure of hydrogen gas increases.

  • PDF

Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART (일체형원자로 SMART 냉각재 순환펌프의 전산성능예측)

  • Kim M. H;Lee J. S;Park J. S;Kim J. I;Kim K. K
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

An Experimental Study on Flow Characteristics of Cavitation Venturi (캐비테이션 벤츄리의 유동 특성에 대한 실험적 연구)

  • Yoon, Wonjae;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • A cavitation venturi is a device that allows a liquid flow rate to be fixed or locked independent of a downstream pressure and has been successfully used in a liquid rocket engine system which requires a stable propellant flow rate. In the present research, four cavitation venturis which have same dimensions except for converging inlet angle and diverging outlet angle, were designed and manufactured. Flow rates through each venturi and upstream/downstream pressures were measured by changing the pressures. From the experimental data, the discharge coefficients and critical pressure ratios were calculated for each venturi. It was found that the inlet and outlet angles of the cavitation venturi affected the discharge coefficient, and the outlet angle influenced on the critical pressure ratio.

Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin (낙동강수계 수질오염총량관리를 위한 유량조사 평가)

  • Kim, Gyeong-Hoon;Kim, Yong-Seok;Park, Bae-Kyung;Yoon, Jong-Su;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

A Study on the Configuration of BOP and Implementation of BMS Function for VRFB (VRFB를 위한 BOP 구성 및 BMS 기능구현에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Chung, Dong-Hwa;Park, Byung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.74-83
    • /
    • 2014
  • This paper proposes a study on the configuration of balancing of plant(BOP) and implementation of battery management system(BMS) functions for vanadium redox flow battery(VRFB) and propose a method consists of sensor and required design specifications BOP system configuration. And it proposes an method of the functions implementation and control algorithm of the BMS for flow battery. Functions of BMS include temperature control, the charge and discharge control, flow control, level control, state of charge(SOC) estimation and a battery protection through the sensor signal of BOP. Functions of BMS is implemented by the sensor signal, so it is recognized as a very important factor measurement accuracy of the data. Therefore, measuring a mechanical signal(flow rate, temperature, level) through the BOP test model, and the measuring an electrical signal(cell voltage, stack voltage and stack current) through the VRFB charge-discharge system and analyzes the precision of data in this paper. Also it shows a good charge-discharge test results by the SOC estimation algorithm of VRFB. Proposed BOP configuration and BMS functions implementation can be used as a reference indicator for VRFB system design.