• Title/Summary/Keyword: discharge area

Search Result 1,549, Processing Time 0.028 seconds

Assessment of Physical River Disturbances in the Namgang-dam Downstream (남강댐하류의 물리적 하천교란 평가)

  • Kim, Ki-Heung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.3
    • /
    • pp.74-86
    • /
    • 2008
  • To assessment the disturbances of the Namgang caused by dam construction, upstream area was selected for the reference reach and downstream area was selected for the comparison reach. And these reaches were surveyed and analyzed according to the assessment criteria of the river disturbances.The artificial factors of river disturbances were classified as river improvement works, dam construction and aggregate dredging. The indexes were physical factors as like epifaunal (bottom), embeddedness, velocity/depth regime, sediment deposition, channel flow status, channel alteration, frequency of riffles, bank stability, vegetative protection, riparian zone etc.The assessment results showed 46% of the assessment criteria which was serious status in dam downstream area and 89.5% of it which was excellent status in dam upstream.Finally, the results showed that physical river environment in downstream area was disturbed by the discharge control and the interception of sediment discharge by dam, consequently this disturbance give rise to impact of ecosystem in river.

Optimal Gate Operation and Forecasting of Innundation Area in the Irrigation Reservoir (관개저수지의 최적수문조작과 침수구역 예측)

  • 문종필;엄민용;김태철
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.486-492
    • /
    • 1999
  • One of the purpose of the reservoir operation is minimizing theinnudation area in the downstream reaches during flood period.l To execute the gate operation properly , it requires lots of real-time data such as rainfall, reservoir level, and water level in the downstrea. Gate operation model was developed with the flood discharge obtained from real-time flood forecasting model and the criterion prepared from the past history of gate operation. Water level in the downstream would be increased by the releasing discharge from the spillway and the area of paddy land flooded in a certain detph and time would be estimated usnig GIS map. Gate operation model was applied to the Yedang reservoir, and the flooded area, depth and time in the paddy land was estimaged.

  • PDF

A Stochastic Analysis of the Water Quality with Discharge Variation in Upper Nakdong River Basin (낙동강 상류 유역에서의 유량변동에 따른 수질의 통계학적 분석)

  • Choi, Hyun Gu;Han, Kun Yeun;Choi, Seung Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.833-843
    • /
    • 2011
  • The purpose of this study is to analysis pollutant loading of upper Nakdong River basin according to the variation of discharge. The correlation between discharge and pollutant concentration and between discharge and pollutant loading were analyzed by statistical method, respectively. Regression equation of pollutant loading and discharge was represented as $L=_aQ^b$ in which L = pollutant loading(kg/day), and b = regression coefficients, and Q = discharge($m^3/day$). The correlation coefficient of study area was in range of 0.8428 to 0.9935. The SS was the highest b value 1.2856~1.7730 among water quality parameters because the pollutant loading of SS was much affected by flow. Additionally, the applicability of the regression equations was verified by comparing predicted results with observed value. The correlation coefficient of verification was in range of 0.8983 to 0.9987 and NSEC was in range of 0.7018 to 0.9960. Therefore the pollutant loading was good correlated with discharge. The main result will be used as basic data for water quality management and design of environment fundamental facilities.

Characteristic Analysis on the Distribution Pattern of Discharge Signals Generated in the Power Cable (전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석)

  • So, Soon-Youl;Hong, Kyung-Jin;Jung, Woo-Seong;Lim, Jang-Seob;Lee, Jin;Lee, Joon-Ung;Kim, Tae-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.1035-1042
    • /
    • 1998
  • After the 1990's, a computer-aided partial discharge(PD) measurement system was referred in part of aging diagnosis using digital signal processing as the new technology has been studied. The PD patterns and relevant information for pattern recognition are discussed in PD research area, because discharge quantity(q), the number of discharge pulse(n) and the applied boltage phase($\varphi$) was combined with the system information of the aging state. This paper investigates the discharge phase and quantity, as well as the number of discharge(n) with regard to discharge signals generated in power cable. therefore, according to characteristic analysis on the distribution of $\varphi$, q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

Capacity Evaluation of Cylindrical Plastic Board Drain with The Composite Discharge Capacity Apparatus (복합통수능시험기를 이용한 실린더형 플라스틱 보드 드레인의 성능 평가)

  • Lee, Chan-Woo;Jung, Du-Hwoe;Kim, Yun-Tae;Jin, Kyu-Nam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.293-299
    • /
    • 2008
  • If a conventional type of Plastic Board Drain (PBD) is installed to the deep clay deposit, it is subjected to a high lateral earth pressure. a flow channel of PBD may be reduced by the collapse of cores and clogged by the intrusion of filter into the space between cores which are made by lateral pressure. It could decrease the ability of initial discharge capacity and the reliability of long term discharge capacity. A cylindrical plastic board drain (C-PBD) considered in this study consists of cylindrical core and several supports so that it can prevent the reduction of area of flow channel from the higher lateral earth pressure effectively. The discharge capacity of C-PBD was compared to that of a conventional PBD through performing experiments using the composite discharge capacity apparatus which can consider in-situ condition such as penetration of drains, ground settlement and discharge capacity. As a result, C-PBD showed much better performance than PBD in the ability of discharge. It was observed that the C-PBD was folded whereas the conventional PBD was folded after the experiment.

  • PDF

The New Structure in AC PDP with Long Discharge Gap for High Luminance and Luminous Efficacy (AC PDP의 휘도 및 효율 향상을 위한 Long Discharge Gap 전극구조 연구)

  • Dong, Eun-Joo;Ok, Jung-Woo;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Joon;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.827-832
    • /
    • 2008
  • One of the most important issues in AC PDP is luminance and luminous efficacy. To improve the luminance and luminous efficacy, new sustain electrode structure which contains long discharge gap is necessary. However, it causes a rise of firing voltage. In this experiment, a new structure is proposed in order to solve this problem. To drop the firing voltage, the hump shaped electrode is inserted into the forward area of the main discharge gap. The experimental results show that proposed structures with 160um discharge gap have high firing voltage by 38V, high luminance by 30% and high luminous efficacy by 15% compared with conventional type having 60um discharge gap. In addition, the proposed structure with hump electrode shows lower firing voltage by 24V compared with the test panel with 160um discharge gap which doesn't have hump electrode though they have similar luminous efficacy.

Influence of Discharge Conditions on the Ignitability of Lycopodium Streams Due to a Single Capacitance Discharge Spark

  • Park, K. S.;M. Yamaguma;T. Kodama;J. H. Joung;Kim, T. Y.;M. Nifuku;M. Takeuchi
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.99-105
    • /
    • 2003
  • The influence of discharge conditions, including the resistance of the sparking circuit, the shape of the electrodes and the width of the falling dust on the ignitability of lycopodium streams were investigated. Discharge characteristics and the ignition phenomena were also explored. When a 100 ㏀ resistor was connected in series with the sparking circuit, the lowest level of minimum ignition energy (MIE) was attained for lycopodium streams. Simultaneously, the area where flammable gas generated increased and the duration of flammable gas generation decreased. That is, the ignita-bility of lycopodium streams depended strongly on the discharge power and discharge duration. Electrodes with sharp tips gave smaller MIEs than those with round tips in a capacitive-inductive sparking circuit, while shape made no difference in a capacitive-resistive circuit. Streams that were too narrow required a considerable amount of energy for ignition.

Discharge characteristics of the Seodo Mulgol Spring, Dokdo (독도 서도 물골 지하수의 유출특성)

  • Cho, Byong-Wook;Yun, Uk;Lee, Byeong-Dae;Song, Won-Kyong;Hwan, Jae-Hong;Choo, Chang-Oh
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • The discharge characteristics of the Seodo Mulgol Spring-the only groundwater-producing area in Dokdo-were evaluated by measurements of discharge rate and electrical conductivity (EC) on five occasions. The Seodo Mulgol Spring is fed by rainfall in upstream areas of the Mulgol cave, and the rainwater of the area moves down along cooling joints developed in trachyandesite II and trachyte, finally discharging at the Mulgol cave. The discharge rate of the Seodo Mulgol Spring varied from 1.12 to 7.02 $m^3/d$ during the study period and EC varied from 2,650 to 3,390 ${\mu}S/cm$, showing a sharp increase during heavy rainfall. The observed variations in discharge rate and EC at the Seodo Mulgol Spring are attributed to the relatively short distance between the recharge area and the Mulgol cave, and to the rapid movement of groundwater through columnar joints developed in trachyandesite II and trachyte. Additional discharge measurements, combined with precise rainfall data, are required at Dokdo to elucidate the discharge characteristics of the Seodo Mulgol Spring.

Sediment Properties and Long-term Bed Change of Munsancheon (문산천의 유사특성 및 장기하상변동 예측)

  • Lee, Jae-Geun;Ahn, Jae-Hyun
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.329-341
    • /
    • 2011
  • This study was conducted with the national river, Munsancheon, which is located in Paju-si, Gyeonggi-do. The sediment discharge of Munsancheon was directly measured to analyze the sediment characteristics, and the results were used in the numerical model to predict the long-term river bed variation. The flow-total sediment discharge relation was derived using the measured total sediment discharge, and the results were compared with the total sediment discharge that was calculated using the existing prediction formula to derive a proper sediment discharge prediction method. In the actual measurements, the total annual sediment discharge was 5,478 ton/year, and the specific sediment discharge was 29.23 ton/$km^2$/year. The Ackers & White formula resulted in the values very close to the actual measurements. With the actual sediment discharge, geographical and hydrologic data as the input variables, HEC-6 and GSTARS models were comparatively analyzed. The test results showed that the HEC-6 model is suitable for the reliable prediction of the long-term river bed variation. Accordingly, the model was used for the long-term river bed variation prediction in this study. In the case of Munsancheon, deposition was continued in the downstream area and erosion occurred in the upstream area on the whole. It was expected that the stream would be stabilized in the river bed condition of 20 years later. The river bed variation was within 1 m, which was at the significance level. In the downstream area that is influenced by tide, however, the accumulation was continuously increasing within the section 2,000-7,000 m from the outlet. It seems that this should be considered in establishing the river management plans.

Marine Algal Flora and Community Structure of the Intertidal Zone around Shingori Nuclear Power Plant, Korea (신고리원자력발전소 주변 해역 조간대의 해조상 및 군집구조)

  • Han, Su Jin;Jang, Jae Gil;Hwang, Youg Hun;Son, Min Ho;Choi, Han Gil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.319-325
    • /
    • 2017
  • Marine algal flora and community structures were examined seasonally at three sites around the Shingori Nuclear Power Plant, Korea from February to November 2016. A total of 76 species were identified, including 9 green, 14 brown and 53 red algae. The greatest number of species occurred at Daesongri (51 species) followed by Sinamri (43 species) and at the discharge area (38 species) during the study period. Of the 76 seaweeds, 59 annuals and 17 warm tolerant species were recorded. Annual average biomass in dry weight varied from $168.02g/m^2$ at the discharge area to $222.53g/m^2$ at Sinamri. The coarsely branched form was the dominant functional form of seaweeds at the three sites. Seaweed community structures at the discharge site were distinguishable by decreasing species richness, biomass, species diversity index, richness index, and evenness index. The ratio of warm tolerance species and the dominance index values were remarkably higher at the discharge than those at the other sites.