• Title/Summary/Keyword: direct system

Search Result 6,850, Processing Time 0.038 seconds

Dyeing Properties of Wool Using Hydrogen Peroxide/Glyoxal Redox System (과산화수소/글리옥살 산화환원계를 사용한 양모의 염색성)

  • Jeong, Dong Seok;Lee, Mun Cheul;Lee, Young Hee;Kim, Kyung Hwan
    • Textile Coloration and Finishing
    • /
    • v.8 no.1
    • /
    • pp.15-25
    • /
    • 1996
  • Wool fabric and merino wool top were dyed with two dyes, C.I. Acid Red 13 and C.I. Direct Blue 1 in presence of hydrogen peroxide/glyoxal redox system at various conditions such as dyeing time, temperature and redox concentration. The pH of dye bath was 4.5 in buffer solution of $KH_{2}PO_{4}$ (0.1mol/1)/$Na_{2}HPO_{4}$ (0.1mol/1). Also dyeing of cotton fabric was carried out with C.I. Direct Blue 1 in absence or presence of redox system. The color depth(K/S) increased with redox concentration and dyeing temperature. The increases in dyeing rate and equilibrium dye exhaustion of Acid Acid 13 and Direct Blue 1 on wool fiber and fabric in the present of hydrogen peroxide/glyoxal have been caused by decreasing in pH value during dyeing process which due to the decomposition of hydrogen ion in glyoxal with the assistance of hydrogen peroxide. But the decreases in exhaustion of Direct Blue 1 on cotton may be attributed to repulsive interac ion between salt and salt.

  • PDF

Comparison Study for the Shear Strength of the Bondings between Stainless Steel Crown/Direct Type Composite Resin and Stainless Steel Crown/Indirect Type Composite Resin (치과 치료학에서 적용되는 접합기술 연구 ; 스테인리스강 크라운에 접합된 직접용 콤포짓트 레진과 간접용 콤포짓트 레진의 전단결합강도 비교)

  • Kim, Gwang-Soo;Baek, Kwang-Woo
    • Journal of Welding and Joining
    • /
    • v.29 no.4
    • /
    • pp.93-99
    • /
    • 2011
  • This study was performed to compare the shear strength of the bondings between stainless steel crown/direct type composite resin and stainless steel crown/indirect type composite resin. Four groups of bonding conditions were prepared. Two groups of bonding conditions were made by the indirect type composite resin system and the other two groups were made by the direct type composite resin system. The shear strength tests were carried out using universal testing machine, Model 4465 of Instron Co.. It was indicated that the bond strength values of the indirect type composite resins were higher than those of the direct type composite resins. TE-SE group was superior to the TE-ONE in indirect type resin system. These results were thought to be the high degree of the polymerization accompanied with temperature and pressure of the resin of indirect type resin. It was also found that indirect composite resin contains less amount of porosity in resin.

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.

The Effect of Hospital SCM on Logistics Performance (병원 통합물류시스템(SCM)이 물류 업무성과에 미치는 영향)

  • Cho, Moon-Suk;Yom, Young-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.3
    • /
    • pp.284-292
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the causal relationships among quality of hospital SCM (system quality, information quality, service quality), perceived usefulness, user satisfaction and logistics performance by hospital staff. Methods: A survey using a structured questionnaire was conducted with 276 hospital staff. Analysis of the data was with both SPSS Win 18.0 for descriptive statistics and AMOS 8.0 for the structural equation model. Results: The hypothetical model yielded Chi-square=8.121 (p=.087), df=4, $x^2$/df=2.030. GFI=.989, AGFI=.942, RMSEA=.066, NFI=.995, CFI=.997 TLI=.990 and showed good fit indices. Three dimensions of quality of SCM had significant direct effects on perceived usefulness. System and service of quality of SCM had significant direct effects on user satisfaction. Perceived usefulness had significant direct effects on user satisfaction. User satisfaction had significant direct effects on logistics performance. Conclusion: These results suggest that logistics performance can be enhanced by user satisfaction, user satisfaction can be enhanced by perceived usefulness, and perceived usefulness can be enhanced by quality of hospital SCM. Further study with various hospitals and various variables is necessary.

Process Study of Direct Laser Lithographic System for Fabricating Diffractive Optical Elements with Various Patterns (다중 패턴의 회절광학소자 제작을 위한 레이저 직접 노광시스템의 공정 연구)

  • Kim, Young-Gwang;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.58-62
    • /
    • 2019
  • Diffractive Optical Elements(DOEs) diffracts incident light using the diffraction phenomenon of light to generate a desired diffraction image. In recent years, the use of diffraction optics, which can replace existing refractive optical elements with flat plates, has been increased by implementing various optical functions that could not be implemented in refractive optical devices and by becoming miniaturized and compacted optical elements. Direct laser lithography is typically used to effectively fabrication such a diffractive optical element in a large area with a low process cost. In this study, the process conditions for fabricating patterns of diffractive optical elements in various shapes were found using direct laser lithographic system, and optical performance evaluation was performed through fabrication.

Design and Implementation of Direct Torque Control Based on an Intelligent Technique of Induction Motor on FPGA

  • Krim, Saber;Gdaim, Soufien;Mtibaa, Abdellatif;Mimouni, Mohamed Faouzi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1527-1539
    • /
    • 2015
  • In this paper the hardware implementation of the direct torque control based on the fuzzy logic technique of induction motor on the Field-Programmable Gate Array (FPGA) is presented. Due to its complexity, the fuzzy logic technique implemented on a digital system like the DSP (Digital Signal Processor) and microcontroller is characterized by a calculating delay. This delay is due to the processing speed which depends on the system complexity. The limitation of these solutions is inevitable. To solve this problem, an alternative digital solution is used, based on the FPGA, which is characterized by a fast processing speed, to take the advantage of the performances of the fuzzy logic technique in spite of its complex computation. The Conventional Direct Torque Control (CDTC) of the induction machine faces problems, like the high stator flux, electromagnetic torque ripples, and stator current distortions. To overcome the CDTC problems many methods are used such as the space vector modulation which is sensitive to the parameters variations of the machine, the increase in the switches inverter number which increases the cost of the inverter, and the artificial intelligence. In this paper an intelligent technique based on the fuzzy logic is used because it is allows controlling the systems without knowing the mathematical model. Also, we use a new method based on the Xilinx system generator for the hardware implementation of Direct Torque Fuzzy Control (DTFC) on the FPGA. The simulation results of the DTFC are compared to those of the CDTC. The comparison results illustrate the reduction in the torque and stator flux ripples of the DTFC and show the Xilinx Virtex V FPGA performances in terms of execution time.

I/Q channel regeneration in 6-port junction based direct receiver (직접 변환 수신기를 위한 Six Port에서의 I와 Q채널의 생성)

  • Kim Seayoung;Kim Nak-Myeong;Kim Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.6 s.324
    • /
    • pp.1-7
    • /
    • 2004
  • The development of direct receiver techniques is expected to be a solution for future wideband or multi-band wireless systems based on software defined radio. In this Paper, we study the regeneration of I and Q signals for the SDR based direct conversion receiver, so that we can handle a wide bandwidth and maintain maximal flexibility in system utilization. After modeling the basic system considering the real wireless communication environment, and studying the impact of imperfect phase imbalance on the performance of a direct conversion receiver, we propose a suboptimal I and Q signal regeneration algorithm for the system. The proposed algerian regenerates I and Q signals using a real time early-late compensator which effectively estimates phase imbalances and gives feedback in a directreceiver. The proposed algorithm is shown to mitigate the impact of AWGN and improves performance especially at low SNR channel condition. According to the computer simulation, the BER performance of the proposed system is at least about 4 dB better than conventional systems under $45{\~}55$ degrees random phase errors.

A study on Design and Performance Evaluation of the BCPFSK Modem (BCPFSK 모뎀 설계 및 성능 평가에 관한 연구)

  • 조형래;김경복
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.869-876
    • /
    • 2001
  • In modern wireless communication, it has been regarded as a important problem for the spectrum efficiency to utilize the limited frequency-resource efficiently. In addition, the system architecture has been designed for low cost, low power consumption and ultra-lightweight. In this paper, we directly modulated the BCPFSK with a superior spectrum efficiency using the DDS and applied the direct conversion to the system architecture. Finally, we designed a transceiver which has the 433 MHz BCPFSK output and evaluated the system performance. In the measured result, we know that as for spectrum and the power efficiency, BCPFSK method is better than conventional one. Also, the results of the designed system is 433.92 MHz in center frequency and about 33 dBc in carrier suppression ratio. And we get the better results in local oscillator leakage and the spurious of the ISM out-band the same as -69dBc and under 60dBc.

  • PDF

New Fuzzy Controller for Speed Control of IPMSM Drive (IPMSM 드라이브의 속도제어를 위한 새로운 퍼지제어기)

  • Lee, Hong-Gyun;Lee, Jung-Chul;Kim, Jong-Gwan;Jung, Tack-Gi;Lee, Young-Sil;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.310-313
    • /
    • 2003
  • This paper is proposed new fuzzy controller for high performance of interior permanent magnet synchronous motor (IPMSM) drive New fuzzy controller take out appropriate amounts of accumulated control input according to fuzzy described situations in addition to the incremental control input calculated by conventional direct fuzzy controller. The structures of the proposed controller is motivated by the problems of direct fuzzy controller. The direct controller generally give inevitable overshoot when one tries to reduce rise time of response especially when a system of order higher than one is under consideration. The undesirable characteristics of the direct fuzzy controller are caused by integrating operation of the controller, even though the integrator itself is introduced to overcome steady state error in response. Proposed controller fuzzy clear out integrated quantities according to situation. This paper attempts to provide a thorough comparative insight into the behavior of IPMSM drive with direct and new fuzzy speed controller. The validity of the comparative results is confirmed by simulation results for IPMSM drive system.

  • PDF

Declutching control of a point absorber with direct linear electric PTO systems

  • Zhang, Xian-Tao;Yang, Jian-Min;Xiao, Long-Fei
    • Ocean Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.63-82
    • /
    • 2014
  • Declutching control is applied to a hemispherical wave energy converter with direct linear electric Power-Take-Off systems oscillating in heave direction in both regular and irregular waves. The direct linear Power-Take-Off system can be simplified as a mechanical spring and damper system. Time domain model is applied to dynamics of the hemispherical wave energy converter in both regular and irregular waves. And state space model is used to replace the convolution term in time domain equation of the heave oscillation of the converter due to its inconvenience in analyzing the controlled motion of the converters. The declutching control strategy is conducted by optimal command theory based on Pontryagin's maximum principle to gain the controlled optimum sequence of Power-Take-Off forces. The results show that the wave energy converter with declutching control captures more energy than that without control and the former's amplitude and velocity is relatively larger. However, the amplification ratio of the absorbed power by declutching control is only slightly larger than 1. This may indicate that declutching control method may be inapplicable for oscillating wave energy converters with direct linear Power-Take-Off systems in real random sea state, considering the error of prediction of the wave excitation force.