• Title/Summary/Keyword: direct spectrum

Search Result 542, Processing Time 0.025 seconds

A Super-Resolution Time Delay Estimation Algorithm for Spread Spectrum Signals (대역 확산 신호를 위한 지연 시간 추정 알고리즘)

  • Shin, Joon-Ho;Myong, Seung-Il;Chang, Eun-Young;Park, Hyung-Rae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2A
    • /
    • pp.119-127
    • /
    • 2012
  • In this paper a super-resolution time delay estimation algorithm is developed for real-time locating systems (RTLSs) that employ a direct-sequence spread spectrum technique, along with its performance analysis in multipath environments. The classical correlation method provides relatively good performance in line-of-sight (LOS) environments but its performance seriously degrades in multipath environments, especially when signals are spaced closer than a PN chip. Therefore we shall develop a super-resolution time delay estimation algorithm that may estimate the time delays of multipath signals even in closely spaced multipath environments using the MUSIC algorithm for direction-of-arrival estimation and analyze its performance by applying the algorithm to the ISO/IEC 24730-2.1 RTLS system. 

Analysis of Cross-Correlation of Extended Non-Linear Binary Sequences (확장된 비선형 이진수열의 상호상관관계 분석)

  • Choi, Un-Sook;Cho, Sung-Jin;Kwon, Sook-Hi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.263-269
    • /
    • 2012
  • Code-Division Multiple-Access(CDMA) allows several users simultaneous access to a common channel by assigning a distinct pseudonoise sequence called spectrum code to each user. Each user in a CDMA system uses a assigned spectrum code to modulate their signal. Choosing the codes used to modulate the signal is very important in the performance of CDMA systems. The best performance will occur when there is good separation between the signal of a desired user and the signals of other users. The receiver synchronizes the code to recover the data. The use of an independent code allows multiple users to access the same frequency band at the same time. In this paper we propose a generalized model of non-linear binary sequence using trace function and analyze cross-correlation of these sequences. These sequences with low correlation, large linear span and large family size, in a direct-sequence spread spectrum communication system, help to minimize multiple access interference, increase security degree of system and enlarge user number.

A Video Watermarking Based on Wavelet Transform Using Spread Spectrum Technique (대역확산방법을 이용한 웨이블릿 기반의 비디오 워터마킹)

  • Kim, Seung-Jin;Kim, Tae-Su;Lee, Kuhn-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.11-18
    • /
    • 2005
  • In this paper, we proposed a video watermarking algerian based on wavelet transform using statistical characteristic of video according to the energy distribution and the spread spectrum technique. In the proposed method, the original video is splitted by spatial difference metric and classified into the motion region and the motionless region according to the motion degree. The motion region is decomposed into 3-levels using 3D DWT and the motionless region is decomposed into 2-levels using 2D DWT The baseband of the wavelet-decomposed image is not utilized because of the image quality. So that the standard deviation of the highest subband coefficients except for the baseband is used to determine the threshold. Binary video watermarks preprocessed by the random permutation and the spread spectrum technique are embedded into selected coefficients. In computer experiments, the proposed algorithm was found to be more invisible and robust than the conventional algorithms.

EEG Analysis Following Change in Hand Grip Force Level for BCI Based Robot Arm Force Control (BCI 기반 로봇 손 제어를 위한 악력 변화에 따른 EEG 분석)

  • Kim, Dong-Eun;Lee, Tae-Ju;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.172-177
    • /
    • 2013
  • With Brain Computer Interface (BCI) system, a person with disabled limb could use this direct brain signal like electroencephalography (EEG) to control a device such as the artifact arm. The precise force control for the artifact arm is necessary for this artificial limb system. To understand the relationship between control EEG signal and the gripping force of hands, We proposed a study by measuring EEG changes of three grades (25%, 50%, 75%) of hand grip MVC (Maximal Voluntary Contract). The acquired EEG signal was filtered to obtain power of three wave bands (alpha, beta, gamma) by using fast fourier transformation (FFT) and computed power spectrum. Then the power spectrum of three bands (alpha, beta and gamma) of three classes (MVC 25%, 50%, 75%) was classified by using PCA (Principal Component Analysis) and LDA (Linear Discriminant Analysis). The result showed that the power spectrum of EEG is increased at MVC 75% more than MVC 25%, and the correct classification rate was 52.03% for left hand and 77.7% for right hand.

Cancellation of MRI Motion Artifact in Image Plane (촬상단면내의 MRI 체동 아티팩트의 제거)

  • Kim, Eung-Kyeu
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.4
    • /
    • pp.432-440
    • /
    • 2000
  • In this study, a new algorithm for canceling MRI artifact due to translational motion in image plane is described. Unlike the conventional iterative phase retrieval algorithm, in which there is no guarantee for the convergence, a direct method for estimating the motion is presented. In previous approaches, the motions in the x(read out) direction and the y(phase encoding) direction are estimated simultaneously. However, the features of x and y directional motions are different from each other. By analyzing their features, each x and y directional motion is canceled by different algorithms in two steps. First, it is noticed that the x directional motion corresponds to a shift of the x directional spectrum of the MRI signal, and the non-zero area of the spectrum just corresponds to the projected area of the density function on the x-axis. So the motion is estimated by tracing the edges between non-zero area and zero area of the spectrum, and the x directional motion is canceled by shifting the spectrum in inverse direction. Next, the y directional motion is canceled by using a new constraint condition, with which the motion component and the true image component can be separated. This algorithm is shown to be effective by using a phantom image with simulated motion.

  • PDF

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Extension of Direct Displacement-Based Design to Include Higher-Mode Effects in Planar Reinforced Concrete Frame Buildings

  • Abebe, Beka Hailu;Lee, Jong Seh
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.299-309
    • /
    • 2018
  • Now that problems with force-based seismic design have been clearly identified, design is inclined toward displacement-based methods. One such widely used method is Direct-Displacement-Based Design (DDBD). Yet, one of the shortcomings of DDBD is considering higher-mode amplification of story shear, moments, and displacements using equations obtained from limited parametric studies of regular planar frames. In this paper, a different approach to account for higher-mode effects is proposed. This approach determines the lateral secant stiffness of the building frames that fulfill the allowable inter-story drift without exceeding the desired story displacements. Using the stiffness, an elastic response spectrum analysis is carried out to determine elastic higher-mode force effects. These force effects are then combined with DDBD-obtained first-mode force effects using the appropriate modal superposition method so that design can be performed. The proposed design procedure is verified using Nonlinear Time History Analysis (NTHA) of twelve planar frames in four categories accounting for mass and stiffness irregularity along the height. In general, the NTHA response outputs compared well with the allowable limits of the performance objective. Thus, it fulfills the aim of minimizing the use of NTHA for planar frame buildings, thereby saving computational resources and effort.

Acquisition of Direct-Sequence Cellular Communication System for Code Division Mutlipie Access (부호 분할 다원 접속을 위한 직접 확산 셀룰라 통신 시스팀의 동기)

  • 전정식;한영열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.2
    • /
    • pp.207-217
    • /
    • 1993
  • In this paper, knowing a priori probability of phase offset between transmitted codes and reference codes in the receiver, we construct the state diagram of acquisition process of the direct sequence spread-spectrum communication system using the expanding window search. The scannings are performed from the cell with higher probability code epoch synchronization to that with lower one. We expand window size from initial value by r times of its previous size in each search, construct the corresponding the state diagrams, and derive average synchronization time using the Markov process and Mason's gain formula. Average synchronization times versus number of search n and detection probability $P_d$ are calculated.

  • PDF

Inhibition of Bacterial Growth with Silver Wire Iontophoresis (은 이온도입이 세균성장에 미치는 영향)

  • Lee Jae-Hyoung;Kim Joo-Young;Jekal Seung-Joo
    • The Journal of Korean Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 1995
  • The silver cation has broad-spectrum antibiotic activity toward Gram-positive, Gram-negative, fungal. aerobic and anerobic micro-organisms. Silver has been used to care of infected wound. pyogenic arthritis, and chronic osteomyelitis. The purpose of this study was to determine whether pure silver wire iontophoresis using milliamperage direct current has an inhibitory effect on growth in vitro of 3 different species of bacteria-Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. Using agarose based media, silver iontophoresis performed at 0, 1, 2, 4, 8 mA for 15 minutes. All experiments were performed in triplicate. Following iontophoresis, inhibition zone width of bacterial growth was measured with calliper. The inhibition of bacterial growth occured at the anodal silver electrode. Inhibition zone width of bacterial growth was significantly increased in all three bacterial species (p<0.05). Between bacterial species, inhibition zone width was not significantly different. Inhibition gone and amperage showed a highly significant positive linear relationship (p<0.001). The result of this study showed that pure silver wire iontophoresis with milliamperage direct current, as well as microamperage direct current, can inhibit bacterial growth in vivo.

  • PDF

Design of Digital Transmitter and Receiver Modules in ILS (항공 계기착륙 디지털 송수신 모듈 설계)

  • Choi, Jong-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.264-271
    • /
    • 2011
  • ILS(Instrument Landing System) is the international standard system for approach and landing guidance. ILS was adopted by ICAO(International Civil Aviation Organization) in 1947 and is currently being used in commercial systems. To design the digital transmitter and receiver modules that can be mounted in the integrated ILS, we propose the digital design methods of digital double AM modulator and demodulator using FPGA chip, DDS(Direct Digital Synthesizer) for generation of sampling clock, demodulator of DDC(Digital Down Converter) structure, and spectrum analyzer using DSP chip. We demonstrate the efficiency of the proposed design method through experiments using developed transmitter and receiver modules. This system can be used as a high-performance commercial system.