• 제목/요약/키워드: direct shear tests

검색결과 315건 처리시간 0.033초

대형직접전단시험에 의한 RAP 복합지반의 전단강도 특성 연구 (A Study on the Shear Strength Characteristics of Composited Ground applying RAP Method by Large Direct Shear Test)

  • 천병식;서덕동;김종산
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.82-89
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the shear strength characteristics according to the area replacement ratio of RAP and the relative density of in-situ ground was studied through soil laboratory tests and large direct shear tests in a model ground. As a result, the internal friction angle tends to increase in proportion to in-situ relative density(Very Loose, Loose, Medium) in composite ground formed by the same area replacement ratio of RAP and also increase in proportion to increasing the area replacement ratio(30, 40, 50%) of RAP in the same ground condition. Furthermore, the comparative analysis between the experimental value and theoretical value of the shear strength is carried out.

  • PDF

동결온도조건 및 수직구속응력에 따른 동결토의 전단강도 변화에 관한 연구 (A study for Shear Strength Characteristics of Frozen Soils under Various Temperature Conditions and Vertical Confining Pressures)

  • 이준용;최창호
    • 한국지반환경공학회 논문집
    • /
    • 제13권11호
    • /
    • pp.51-60
    • /
    • 2012
  • 동토지반의 기초구조물을 설계하는데 있어 기초의 안정성을 지배하는 설계정수인 동결토의 전단강도 및 동착강도를 측정하기 위하여 지난 50여 년 동안 많은 연구가 수행되어 오고 있다. 하지만, 아직까지 동결토의 전단강도 특성에 관한 많은 연구들은 토사 종류, 수직구속응력, 동결온도조건 등 여러 가지 영향인자 중 제한된 영향인자의 변화를 통해 수행되어 왔다. 동결토는 일반 토질과는 달리 토립자, 물, 공기뿐만 아니라 얼음을 포함한 4상으로 구성되어 있으며, 동토의 역학적인 성질의 변화는 일반적으로 온도, 수직구속응력, 동토의 구성물질에 따라 영향을 받는다. 이와 같은 동결토의 전단강도 특성을 측정하기 위하여 영하 30도의 저온환경에서도 동작이 가능하도록 설계된 동결토 직접전단시험기를 활용하였으며, 동토지역의 저온환경을 모사하기 위하여 대형 냉동챔버 내에 직접전단시험기를 설치하였다. 동결토의 전단강도 특성을 측정하기 위하여 비교적 균질한 입경분포를 지닌 주문진표준사 및 실리카모래와 입도분포가 좋은 화강풍화토를 활용하였다. 각각 세가지 시료에 대하여 전단시험은 세가지 동결온도 조건 및 수직구속응력 조건에서 수행되었으며, 그 결과를 바탕으로 동결온도조건 및 수직구속응력이 동결토의 전단강도에 미치는 영향을 분석하였다. 전반적으로 동결토의 전단강도는 동결온도가 낮아질수록 증가하는 경향을 보였으나, 수직구속응력에 의한 영향은 미미한 것으로 나타났다.

Cyclic behavior of various sands and structural materials interfaces

  • Cabalar, Ali Firat
    • Geomechanics and Engineering
    • /
    • 제10권1호
    • /
    • pp.1-19
    • /
    • 2016
  • This paper presents the results of an intensive experimental investigation on cyclic behavior of various sands and structural materials interface. Comprehensive measurements of the horizontal displacement and shear stresses developed during testing were performed using an automated constant normal load (CNL) cyclic direct shear test apparatus. Two different particle sizes (0.5 mm-0.25 mm and, 2.0 mm-1.0 mm) of sands having distinct shapes (rounded and angular) were tested in a cyclic direct shear testing apparatus at two vertical stress levels (${\sigma}=50kPa$, and 100 kPa) and two rates of displacement ($R_D=2.0mm/min$, and 0.025 mm/min) against various structural materials (i.e., steel, concrete, and wood). The cyclic direct shear tests performed during this investigation indicate that (i) the shear stresses developed during shearing highly depend on both the shape and size of sand grains; (ii) characteristics of the structural materials are closely related to interface response; and (iii) the rate of displacement is slightly effective on the results.

직접전단장비를 이용한 토석류의 전단강도 및 유변학적 특성에 대한 입도분포의 영향 연구 (Effects of Grain Size Distribution on the Shear Strength and Rheological Properties of Debris Flow Using Direct Shear Apparatus)

  • 박근우;홍원택;홍영호;정승원;이종섭
    • 한국지반공학회논문집
    • /
    • 제33권12호
    • /
    • pp.7-20
    • /
    • 2017
  • 본 연구에서는 전단특성 및 유변학적 정수를 모두 산정할 수 있는 직접전단실험 장비를 이용하여 조립토와 세립토에 대하여 전단강도 및 유변학적 특성에 대한 입도분포의 영향을 조사하고자 하였다. 최대입경 0.075mm의 세립토와 최대입경이 0.425mm이고, 세립분 함량이 17%인 조립토를 건조상태와 액성한계상태로 조성하여, 산사태 분류기준에 따라 재활성 산사태(reactivated landslide) 혹은 붕괴직후 토석류 속도에 해당하는 전단속도에 대하여 전단강도를 산정하였다. 또한, 유변학적 특성 평가를 위해 액성한계상태로 조성된 조립토와 세립토에 대하여 서로 다른 세 가지의 전단변형률속도로 반복적으로 전단하며 잔류전단강도를 측정하였다. 측정된 잔류전단강도와 전단변형률속도와의 관계를 통해 빙햄모델의 소성 점도와 항복응력을 산정하였다. 건조 및 액성한계상태에서 조성된 시료에 대하여 첨두전단강도에서 산정한 점착력의 경우, 세립토에서 조립토보다 더 크게 산정되었으며, 내부마찰각은 조립토에서 더 크게 산정되었다. 유변학 정수의 경우, 소성 점도와 항복응력이 조립토보다 세립토에서 더 큰 것으로 나타났다. 본 연구는 재활성 산사태 혹은 붕괴직후 토석류의 거동예측에 효과적으로 활용될 것으로 기대된다.

정적마찰 시험을 통한 접촉전단 특성평가 (Evaluation of Interface Shear Properties Through Static Friction Tests)

  • 장용채;이승은;서지웅;존 바우더스
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.813-818
    • /
    • 2009
  • Shear properties of plastic bottle film/plastic bottle film and plastic bottle film/granitic soil which were evaluated from static friction tests. The monotonic shear experiments were performed by using an tilt table apparatus and large direct shear device. The test results showed that the friction angle of each interface and the interface depended on the amount of normal stress, the type of the interface used. Therefore, the testing method should be determined carefully by considering the type of loads and normal stress expected in the field with using the materials installed in the site.

  • PDF

Physical and numerical modelling of the inherent variability of shear strength in soil mechanics

  • Chenari, Reza Jamshidi;Fatahi, Behzad;Ghoreishi, Malahat;Taleb, Ali
    • Geomechanics and Engineering
    • /
    • 제17권1호
    • /
    • pp.31-45
    • /
    • 2019
  • In this study the spatial variability of soils is substantiated physically and numerically by using random field theory. Heterogeneous samples are fabricated by combining nine homogeneous soil clusters that are assumed to be elements of an adopted random field. Homogeneous soils are prepared by mixing different percentages of kaolin and bentonite at water contents equivalent to their respective liquid limits. Comprehensive characteristic laboratory tests were carried out before embarking on direct shear experiments to deduce the basic correlations and properties of nine homogeneous soil clusters that serve to reconstitute the heterogeneous samples. The tests consist of Atterberg limits, and Oedometric and unconfined compression tests. The undrained shear strength of nine soil clusters were measured by the unconfined compression test data, and then correlations were made between the water content and the strength and stiffness of soil samples with different consistency limits. The direct shear strength of heterogeneous samples of different stochastic properties was then evaluated by physical and numerical modelling using FISH code programming in finite difference software of $FLAC^{3D}$. The results of the experimental and stochastic numerical analyses were then compared. The deviation of numerical simulations from direct shear load-displacement profiles taken from different sources were discussed, potential sources of error was introduced and elaborated. This study was primarily to explain the mathematical and physical procedures of sample preparation in stochastic soil mechanics. It can be extended to different problems and applications in geotechnical engineering discipline to take in to account the variability of strength and deformation parameters.

Tests of the interface between structures and filling soil of mountain area airport

  • Wu, Xueyun;Yang, Jun
    • Geomechanics and Engineering
    • /
    • 제12권3호
    • /
    • pp.399-415
    • /
    • 2017
  • A series of direct shear tests were conducted to investigate the frictional properties of the interface between structures and the filling soil of Chongqing airport fourth stage expansion project. Two types of structures are investigated, one is low carbon steel and the other is the bedrock sampled from the site. The influence of soil water content, surface roughness and material types of structure were analyzed. The tests show that the interface friction and shear displacement curve has no softening stage and the curve shape is close to the Clough-Duncan hyperbola, while the soil is mainly shear contraction during testing. The interface frictional resistance and normal stress curve meets the Mohr-Coulomb criterion and the derived friction angle and frictional resistance of interface increase as surface roughness increases but is always lower than the internal friction angle and shear strength of soil respectively. When surface roughness is much larger than soil grain size, soil-structure interface is nearly shear surface in soil. In addition to the geometry of structural surface, the material types of structure also affects the performance of soil-structure interface. The wet interface frictional resistance will become lower than the natural one under specific conditions.

Effect of cement stabilization on geotechnical properties of sandy soils

  • Shooshpasha, Issa;Shirvani, Reza Alijani
    • Geomechanics and Engineering
    • /
    • 제8권1호
    • /
    • pp.17-31
    • /
    • 2015
  • An experimental program was performed to study the effects of cement stabilization on the geotechnical characteristics of sandy soils. Stabilizing agent included lime Portland cement, and was added in percentages of 2.5, 5 and 7.5% by dry weight of the soils. An analysis of the mechanical behavior of the soil is performed from the interpretation of results from unconfined compression tests and direct shear tests. Cylindrical and cube samples were prepared at optimum moisture content and maximum dry unit weight for unconfined compression and direct shear tests, respectively. Samples were cured for 7, 14 and 28 days after which they were tested. Based on the experimental investigations, the utilization of cemented specimens increased strength parameters, reduced displacement at failure, and changed soil behavior to a noticeable brittle behavior.

Perfobond Rib 전단연결재를 사용한 실험체의 전단강도 분석 (Analysis on Shear Force of Specimens Using Perfobond Rib Shear Connector)

  • 최진웅;박병건;김형준;정호성;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.138-147
    • /
    • 2011
  • 본 연구의 목적은 직접전단응력 및 휨 전단응력의 비교분석을 통하여 Perfobond Rib 전단연결재를 사용한 구조물의 하중방향에 따른 전단응력 분석이다. 직접전단응력 분석을 위해서 5개의 변수로 Perfobond Rib 전단연결재 실험체 5개를 제작하고 Push-out Test를 실시하였다. 실험 후 Perfobond Rib 전단연결재의 전단저항 메커니즘을 규명하고, 직접전단응력에 영향을 미치는 주요 인자를 바탕으로 직접전단력을 산출할 수 있는 제안식을 제시하였다. 또한 휨 전단응력의 분석을 위해 강-콘크리트 합성 바닥판 실험체를 제작하고 정적 휨실험을 실시하였다. 정적 휨실험을 바탕으로 휨 거동특성을 분석하고 휨 전단응력을 계산하였다. 직접전단응력과 EN 1994-1-1을 통해 계산된 휨 전단응력을 비교하여 하중방향에 따른 전단저항응력에 대해서 분석을 하였다.

암석 절리면의 거칠기와 전단거동의 특성 분석 (Shear Behavior Characteristics of Rock Joints Considering Roughness Parameters)

  • 김동규;홍영기;김종우
    • 터널과지하공간
    • /
    • 제26권5호
    • /
    • pp.384-395
    • /
    • 2016
  • 절리면의 전단거동 특성을 알아보기 위하여 암석종류와 거칠기가 서로 다른 110개의 자연 암석 절리면 시료에 대하여 거칠기 측정시험과 다단계전단시험을 실시하였다. 시험 암석은 석영반암, 석영안산암, 화강암, 편마암의 4가지 종류이고, 절리면은 JRC값에 따라 3가지 그룹으로 분류하였다. 거칠기 측정시험을 통해 절리면의 거칠기 파라미터를 분석하였으며, 다단계전단시험을 통해 암석종류, 절리면 거칠기, 수직응력의 변화가 각종 전단특성에 미치는 영향을 알아보았다. 절리면의 거칠기와 수직응력이 커질수록 최대전단강도와 전단강성은 증가하였고, 거칠기가 작고 수직응력이 커질수록 팽창각은 감소하였다. 절리면의 전단특성은 암석종류와 거의 무관한 것으로 나타나 모암의 강도보다는 거칠기와 수직응력에 더 큰 영향을 받았다. 또한 동일 암석 절리면에 대한 다단계시험과 직접전단시험의 결과를 비교분석함으로써 두 시험법의 특징을 고찰하였으며, 다단계시험으로 구한 팽창각은 시험 전반부의 낮은 수직응력수준에서 얻은 값만 유효한 것으로 나타났다.