• Title/Summary/Keyword: direct heating

Search Result 330, Processing Time 0.036 seconds

Effect of Floor Heating System on Housing Environment and Performance in Broiler Production (바닥난방이 육계의 사육환경 및 생산성에 미치는 영향)

  • 최희철;이덕수;서옥석;한정대;강희설;권두중;곽정훈;강보석;장병귀
    • Korean Journal of Poultry Science
    • /
    • v.26 no.3
    • /
    • pp.189-193
    • /
    • 1999
  • This experiment was conducted to investigate the effect of floor heating system on housing environment and performance in broiler production. PVC heating pipes(in 25cm spacing) were covered with concrete under the litter. Floor heating system was compared with conventional direct heating system. Each treatment had two replicates of 110 birds each. Litter moisture content was significantly reduced in floor heating system than conventional direct heating system(P〈0.05). Dust concentration was higher in floor heating system because of low litter moisture content. CO$_2$concentration was 2,900ppm and 1,500ppm on the direct heating system and floor heating system, respectively at the age of 1 week. Body weight was significantly higher in floor heating system at 7 weeks of age(P〈0.05). The results of the trial show that floor heating was useful heating system for broiler production.

  • PDF

A Heating Apparatus for Semiconductor Manufacturing using Direct Heating Method (직접 가열 방식을 이용한 반도체 제조용 히팅 장치)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.408-411
    • /
    • 2008
  • As to this research is new structure of the semiconductor substrate heating apparatus. The fast thermoresponsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. For this, it adheres closely to the substrate, in which the photosensitive film is coated and the heating plate layer, adhering closely to the floor side of a substrate the mica layer which adheres closely to the floor side of the upper heating plate layer in order to minimize an insulation and heat loss, and the lower part of the mica layer and it is comprised of the floor plate layer. The heating plate layer forms the continued groove portion over the floor side whole. The sheath heater for heating a substrate is inserted with the groove portion and the heating plate layer is comprised. It is confirmed that by using the new substrate heating structure, the temperature change of the heating plate against the time is observed. Then, there is the electric power saving effect of about 40% in comparison with the existing method.

LMDI Decomposition Analysis for Electricity Consumption in Korean Manufacturing (LMDI 요인 분해분석을 이용한 우리나라 제조업 전력화 현상에 관한 연구)

  • Han, Joon
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.137-148
    • /
    • 2015
  • So far, the phenomenon of "electrification" has been deepened in Korean industry and especially direct heating energy which accounted for 44.0%(2010) of total energy consumed in Korean manufacturing has been significantly electrified. This paper decomposed electricity consumption for direct heating in Korean manufacturing from 1992 to 2012 using LMDI(Log Mean Divisia Index). This paper includes 4 different factors such as electricity proportion effect, direct heating proportion effect, energy intensity effect and added value effect. And this paper compared the consumption pattern by business type. As results, electricity proportion effect had contributed the most to the increase of electricity consumption for direct heating in Korean manufacturing. And Petrol-Chemical and Iron & Steel had the most electrification of direct heating.

An Assemble and Expandable Substrate Heating Apparatus for the Semiconductor Manufacturing (조립과 확장이 가능한 반도체 제조용 기판 가열 장치)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.67-71
    • /
    • 2009
  • This research is a new structure of the semiconductor substrate heating apparatus in which the assembly and expansion are possible. The fast thermo-responsive according to the direct heating structure of the heating plate layer adhering closely to the floor side of a substrate and the fast heat loss minimization can be accomplished. Moreover, the contact area of the sheath heater, which is the heating plate layer built-in heating apparatus, is increased, so that it has more heating valid area. There is no problem with the deformation interpreted in the state where it assembles the block of a several of the simulation result structure, the safety, and the stress. In addition, it is confirmed that building a large-size heating block is possible since the temperature deflection of the manufactured plate is lower than the standard value.

Performance Analysis of Water Direct Contact Air Conditioning System (물 직접접촉식 공기조화장치의 성능해석)

  • Yoo, S.Y.;Kwon, H.K.;Song, J.;Kim, K.Y.;Park, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.158-163
    • /
    • 2001
  • Performance of the water direct contact air conditioning system, in which heat and mass are transferred directly between air and water droplet, is simulated by semi-empirical method. This system improves transport efficiency compared to conventional indirect contact system and cooling, heating, dehumidification and humidification are attained with one unit. In this study, temperature and flowrate for air and water are measured in the various cooling and heating conditions, and correlations for $h_{c}A/c_{pm}$ are derived from these data. Cooling and heating characteristics of the water direct contact air conditioning system are investigated using correlations.

  • PDF

Development of a Direct-Vapor Heating Inhalator (증기직접가열방식의 비염치료기 개발)

  • Jeon, Chang-Wan;Kang, Taesam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.322-327
    • /
    • 2013
  • Recently many people have been troubled with perennial allergic rhinitis. But there is no way to cure for root of it until now. Therefore many medical treatments to release symptoms of perennial allergic rhinitis have been researched. One of them is localized aerosol hyperthermia, which injects $42^{\circ}C{\sim}43^{\circ}C$ vapor into nasal cavity. Vapor inhalator for localized aerosol hyperthermia has been researched in foreign country. But on the other hand it has rarely been researched inside of the country. Since most clinics and hospitals have used imported vapor inhalator, it is needed to develop domestic vapor inhalator. In the paper, a superior vapor inhalator compared to former developed one is developed. The superiority of it comes from direct-vapor heating instead of water heating to control vapor temperature. The developed vapor inhalator has shorter rising time than the existing one because of direct-vapor heating. Furthermore vapor generation part and control part of the vapor inhalator developed as one piece mock-up. It enables the vapor inhalator to have smaller size. Many laboratory tests are performed and compared to existing results to prove its performance.

Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load (직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토)

  • Kim, Soo-Kyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

Characteristics of plasma sprayed composite YSZ/Ni-Cr resistant heating coatings (YSZ/Ni-Cr 저항 발열 복합용사피막의 특성)

  • 김병수;박경채;김태형;양병모
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.111-113
    • /
    • 2003
  • The existing heating unit is indirect-heating method that make use or the nichrome wire or halogen lamp. The indirect-heating method has the demerits of long warming time, high power consumption and many organization parts. In this study, the heating unit of direct-heating method manufactured as being the thermal spray coating of conductive heating material on the surface of heating unit in order to improve the demerits of indirect-heating method. And YSZ added Ni-20Cr that had moderate electrical resistivity was chosen of the conductive heating material.

  • PDF

Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger (지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능)

  • Kim, Y.H.;Kang, Y.K.;Sung, M.S.;Ryou, Y.S.;Kim, J.G.;Jang, J.K.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

Straightening Process of Micro Wires (마이크로 와이어의 직선화 처리에 관한 연구)

  • Kim, Woong-Kyum;Hong, Nam-Pyo;Kim, Byeong-Hee;Kim, Heon-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1148-1153
    • /
    • 2006
  • This paper deals with the effect of the direct heating method(DHM) for straightening the micro wire. Straightened micro wires have been widely used in the fields of the medicine and the semi-conductor. We have developed a micro wire straightening system by using the direct wire heating method. To controling the tension of the micro wire during the heating and straightening process, a precision tension sensor was set up. In order to avoid the surface oxidation during the heating process, the argon inert gas was supplied to the vicinity of the wire. And, this paper shows the correlation between the tension and the current when arson gas supplied to the tungsten wire. Through several experiments, the optimal tension and current were found. Also, higher straightness $({\approx}1{\mu}m/1000{\mu}m)$ and roundness$(<{\Phi}{\pm}2{\mu}m/100{\mu}m)$ founded when $500{\mu}600gf$ tension and 1.5 ampere.