• Title/Summary/Keyword: direct current

Search Result 2,741, Processing Time 0.036 seconds

Effect of Applying tDCS by Inactive Electrode Placement to Cognitive Response on Stroke Patients (경피두개직류자극 적용 시 비활성 전극의 위치가 뇌졸중 환자의 인지반응에 미치는 영향)

  • Hwang, Ki-Kyeong;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.11 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Purpose : This study was to identify the effect of cognitive reaction following inactive electrode placement when applying anodal transcranial direct current stimulation over the primary motor cortex. Methods : For this study a total of 28 stroke patients participated. Before applying transcranial direct current stimulation, cognitive reaction was measured (P300 of event related potential, cognitive reaction time), and subjects were randomly assigned to two group. Transcranial direct current stimulation was applied to the scalp with an intensity of $0.04mA/cm^2$ for 15 minutes. All subjects were given an anode transcranial direct current stimulation over the primary motor area and inactive electrodes over the deltoid muscle (group I) and supra-orbital area (group II). Cognitive reactions were measured after applying transcranial direct current stimulation. Results : For this study a total of 28 stroke patients participated. Before applying transcranial direct current stimulation, cognitive reaction was measured (P300 of event related potential, cognitive reaction time), and subjects were randomly assigned to two group. Transcranial direct current stimulation was applied to the scalp with an intensity of $0.04mA/cm^2$ for 15 minutes. All subjects were given an anode transcranial direct current stimulation over the primary motor area and inactive electrodes over the deltoid muscle (group I) and supra-orbital area (group II). Cognitive reactions were measured after applying transcranial direct current stimulation. Conclusion : Thus transcranial direct current stimulation on the primary motor area may help cognitive reaction regardless of inactive electrode placement.

The Effect of Direct and Variable Current on Current Efficiency of Copper Anode (조동의 전류효율에 미치는 직류 및 가변전류의 영향)

  • Ahan, Sung-Chen;Lee, Sang-Mun;Kim, Yong-Hwan;Chung, Won-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.5
    • /
    • pp.223-228
    • /
    • 2006
  • The current efficiency of copper anode containing impurities in copper sulfate solution for electrorefining was studied at various current type such as direct current, variable current and periodic reverse current. The passivity behavior was investigated by galvanostatic technique. The results obtained were that current efficiency of variable current was higher than those of direct current and periodic reverse current. The increased current efficiency could be explained by the formation of slime structure with lower average resistance due to variable current. The frequency of various factors in variable current condition has a greatest effect on current efficiency. It appeared that frequency increased current efficiency when increased from 1 to 4, but further increases did not have an effect.

Analysis on the Short Circuit Current of a Low Voltage Direct Current(DC) Distribution System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 저전압 직류 배전 시스템의 단락 고장 전류 분석)

  • Ahn, Jae-Min;Jeon, Jeong-Chay;Lim, Young-Bae;Bae, Seok-Myeong;Byeon, Gil-Sung;Lee, Kyoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • In this paper, we analyzed the short circuit current of a low voltage direct current distribution system. For the analysis, we performed the modeling of the low voltage direct current distribution system with a 6-pulse three-phase thyristor rectifier using the PSCAD/EMTDC, surveyed impedance of sources, transformers and distribution lines to run a simulation. A result of the simulation is that short circuit currents of the direct current distribution system with the rectifier decreased due to a thyristor-ON-resistance(Ron). But in case of the low thyristor-ON resistance, output fault current of the rectifier increased over three-phase short circuit current of an AC power system without a rectifier by regular ratio of the rectifier. Because the output fault current of the rectifier can increase over interrupting the capacity of circuit breakers, studying short circuit currents of a low voltage direct current distribution system with a rectifier is necessary for introducing the direct current distribution systems.

A Study on Characteristics of Water Content Changes of Wastewater Sludge Using Direct Current Electricity (직류전기를 이용한 하수슬러지 함수율 변화특성에 관한 연구)

  • Ahn, Jeong-Mo;Song, Ji-Yun;Joo, Jae-Young;Bae, Yun-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2010
  • This study examined the change of water content in sludge using direct current electric equipment for decreasing the amount of sludge. The experiment showed that the average density of solids in the sludge treated by direct current before the centrifugal dewatering process was increased by 47.8%, when compared to those not treated by direct current. From the result of measuring the granularity of the sludge by the direct current treatment, that the average particle size of the sludge that was not exposed to the electric current was 52.36 ${\mu}m$, and more than 90% of the sludge was <94.29 ${\mu}m$ in size. On the other hand, the average particle size of the sludge passed through the direct current was 28.67 ${\mu}m$, and more than 90% of the sludge was 52.46 ${\mu}m$. This means that the average particle size of the sludge treated by the direct current was 45.2% smaller, and the standard deviation of granularity was improved. Because of water that separated from sludge moves to the (+) pole, larger particles become smaller and fine particles combine together, resulting in the equalization of the particle size. On the sludge after the centrifugal dehydrator, the change of the water content by the direct current was measured. The results showed that the average density of the solids was increased by 44.2% compared.

Effects of Transcranial Direct Current Stimulation with Aerobic Exercise on Lower Extremity Muscle Endurance for Elderly Women (경피 두개 직류 전류자극과 병행한 유산소운동이 노인 여성의 근지구력에 미치는 영향)

  • Cho, Namjeong;Kim, Suhyon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.2
    • /
    • pp.117-123
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the effect of increased brain activity on the muscle endurance and the effect of brain activation through the combination of transcranial direct current stimulation and aerobic exercise on elderly woman. Methods : To investigate the effect of the muscle endurance on right leg, muscle endurance was evaluated by measuring the surface EMG of the muscles of the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius muscle. Results : There was a significant difference in the pre and post comparisons of muscle endurance on rectus femoris, biceps femoris, tibialis anterior muscle (p<.05). Difference of Combination of transcranial direct current stimulation and aerobic exercise group median frequency was smaller than control group (p<.05). There was not a significant difference in the pre and post comparisons of muscle endurance on biceps femoris, and gastrocnemius muscle. Difference of Combination of transcranial direct current stimulation and aerobic exercise group median frequency was showed a similar pattern. Conclusion : Through these results, It was found that increasing the brain activity by the transcranial direct current stimulation improves the exercise capacity on the elderly women. Combination of transcranial direct current stimulation and aerobic exercise maybe applied as an effective treatment for improving muscular endurance.

Effect of Welding Current Type on Weldability in Spot Welding of Aluminum Alloy (알루미늄 합금의 점용접에서 용접전류 형태가 용접성에 미치는 영향)

  • 한용섭
    • Journal of Welding and Joining
    • /
    • v.15 no.2
    • /
    • pp.89-99
    • /
    • 1997
  • Spot welding is one of the important welding processes for the construction of thin metal sheet. Because of low investment cost, alternating welding current is widely applied for power source. Direct current type could be, however, recommened for high quality weldment. In this study, the effect of welding current type on the weldability and the electrode life in spot welding of aluminium alloy were investigated. Various welding tests were done by using three phase direct and alternating welding current, respectively. In spite of high variation of welding force, weld quality and electrode life with alternating welding current were shown better results than those with direct current for 2mm thick alumininum alloy sheets. This was due to excessive erosion of the positive electrode in direct welding current compared with the negative one. On the contrary to 2mm sheets, the welding parameters of alternating current for 1mm sheets must be carefully selected.

  • PDF

Design of Direct-Current Fuzzy Controller for Mitigating Commutation Failure in HVDC System

  • Gao, Benfeng;Yuan, Kewei;Dong, Peiyi;Luo, Chao;Zhao, Shuqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1450-1458
    • /
    • 2018
  • Commutation failures can deteriorate the availability of high-voltage direct current (HVDC) links and may lead to outage of the HVDC system. Most commutation failures are caused by voltage reduction due to ac system faults on inverter side. The commutation failure process can be divided into two stages. The first stage, from the occurrence to the clearing of faults, is called 'Deterioration Stage'. The second stage, from the faults clearing to restoring the power system stability, is called 'Recovery Stage'. Based on the analysis of the commutation failure process, this paper proposes a direct-current fuzzy controller including prevention and recovery controller. The prevention controller reduces the direct current to prevent Commutation failures in the 'Deterioration Stage' according to the variation of ac voltage. The recovery controller magnifies the direct current to speed up the recovery of power system in the 'Recovery Stage', based on the recovery of direct voltage. The validity of this proposed fuzzy controller is further proved by simulation with CIGRE HVDC benchmark model in PSCAD/EMTDC. The results show the commutation failures can be mitigated by the proposed direct-current fuzzy controller.

Tunneling Current Calculation in HgCdTe Photodiode (HgCdTe 광 다이오드의 터널링 전류 계산)

  • 박장우;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.9
    • /
    • pp.56-64
    • /
    • 1992
  • Because of a small bandgap energy, a high doping density, and a low operating temperature, the dark current in HgCdTe photodiode is almost composed of a tunneling current. The tunneling current is devided into an indirect tunneling current via traps and a band-to-band direct tunneling current. The indirect tunneling current dominates the dark current for a relatively high temperature and a low reverse bias and forward bias. For a low temperature and a high reverse bias the direct tunneling current dominates. In this paper, to verify the tunneling currents in HgCdTe photodiode, the new tunneling-recombination equation via trap is introduced and tunneling-recombination current is calculated. The new tunneling-recombination equation via trap have the same form as SRH (Shockley-Read-Hall) generation-recombination equation and the tunneling effect is included in recombination times in this equation. Chakrabory and Biswas's equation being introduced, band to band direct tunneling current are calculated. By using these equations, HgCdTe (mole fraction, 0.29 and 0.222) photodiodes are analyzed. Then the temperature dependence of the tunneling-recombination current via trap and band to band direct tunneling current are shown and it can be known what is dominant current according to the applied bias at athe special temperature.

  • PDF

Performance of Direct-Conversion Receiver with AC-Coupling in DC-Offset interference environment (DC-Offset 간섭환경에서 AC-Coupling을 갖는 직접변환 수신기의 성능)

  • 성봉훈;송윤정;김영완;김내수;서종수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.9-14
    • /
    • 2002
  • Direct-conversion receiver(DCR) architecture has superior advantages in size, cost, and power over superheterodyne receiver architectures. However, the use of direct-conversion receiver architecture has been limited due to the direct-current offset noise. The ac coupling, which is used to overcome the direct-current offset noise, causes an inter-symbol interference(ISI), whose effects can be effectively mitigated using an equalizer. In this paper, the performance of a direct-conversion receiver with ac coupling in the presence of direct-current offset is analyzed via computer simulation. The simulation result shows that by using decision feedback equalizer with LMS(Least Mean Square) algorithm, signal-to-noise ratio loss of the direct-conversion receiver compared to the idea receiver can be reduced to less than 1㏈ for corner frequencies as large as 10% of the symbol rate.

  • PDF

An Analysis on the Damage Compensation of Hanwoo Farmers as a Result of the Korea-U. S. Free Trade Agreement (한.미 FTA 체결에 따른 한우농가 피해보전효과 분석)

  • Choi, Se-Hyun;Cho, Jae-Hwan;Gim, Uhn-Soon
    • Korean Journal of Organic Agriculture
    • /
    • v.21 no.4
    • /
    • pp.523-538
    • /
    • 2013
  • To help improve the current government practice of direct damage-compensation policies, resulting from the loss of profit, sustained by Hanwoo farmers, as a result of the recent Korea-U. S. Free Trade Agreement (FTA), this research aims to examine any problems or issues caused by said policies. To accomplish this task, we have established Hanwoo-SIMO model and estimated the damage of Hanwoo farmers, one without the implementation of the FTA and another with the FTA, to compare and contrast the two. We then analyzed the efficacy of the current government policies. According to our analysis, the current direct compensation policies for the loss of profit on the part of Hanwoo farmers are insufficient. To address this problem, we recommend the government enact a new direct damagecompensation law to address the following issues. First, as the base formula of damage-compensation, the government should use current price of the beef rather than the annually changing flexible price. Second, the flexible control index should remain fixed at 1.0 rate while the government prepares the adequate amount of the damage compensating direct payment resulting from the FTA. Third, the direct government compensation policy should extend beyond the current 15 years (2013-2026) as the profit loss is expected to increase after the midpoint of the FTA.