• Title/Summary/Keyword: diopter

Search Result 84, Processing Time 0.021 seconds

Study of the Correlation and Ocular Components in Preschool Children (취학전 어린이들의 안광학 성분 측정 및 상관성 분석)

  • Jeon, Soon-Woo;Hwang, Hye-Kyung;Lee, Sun Haeng;Park, Chun-Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.201-206
    • /
    • 2010
  • Purpose: This study was to know the correlation among the dimensions of ocular components and refractive error on kindergarten children. Methods: The subjects were 80 preschool students who had no eye diseases. The refraction, corneal diopter, corneal radius, inter-pupillary distance, axial length, anterior chamber depth and dominant eye were measured and analysed. Results: It was shown that the highest correlation was between the axial length and the corneal diopter (r=-0.674, p=0.000). The ratio of height, weight and axial length (AL) to Corneal radius (CR) ratio were positively correlated with the axial length (r=0.351, r=0.408, r=0.488). The spherical equivalent of the refractive error and the corneal diopter were negatively correlated with the axial length (r=-0.302, r=-0.674). The anterior chamber depth and the corneal diopter were positively correlated with the AL/CR ratio (r=0.422, r=0.280). The spherical equivalent of the refractive error and the corneal radius were negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the preschoolers.

The Visual Acuity and Refraction on Students of Primary School Using Eyeglasses in Kyung-Nam Region (경남지역 안경 착용자 초등학생들의 시력과 굴절)

  • Kim, Douk-Hoon;Mun, Joung-Hak;Kim, Joung-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.345-350
    • /
    • 2006
  • The study of the visual acuity and refraction status was performed to the students of primary school using eyeglasses in Kyung Nam region, Korea. Two hundred sixty three subjects with various styles of ametropia were analyzed the visual acuity and refraction examination by the subjective and objective tools. The results of study were as follows; 1) According to the increase of age of subjects, the visual acuity of binocular in naked eyes was decrease. However ametropia was increase. 2) The high frequency of ametropia types in the binocular was simple myopia, and the next order of high frequency was mixed astigmatism, myopic compound astigmatism, simple hyperopia, and hyperopic compound, respectively. 3) On the power of spherical refractive error of ametropia, the high frequency was -1.00 diopter, and the next order of high frequency was -2.00 diopter, +2.00 diopter, -3.00 diopter, and so on, respectively. 4) According to the increase of subjects ages, the changes of dioptric power of myopic spheric power was increase. however the frequency of the boy and girl was similar results, also the dioptric values of refractive status in binocular was similar results. As the results of this study, we conclude that the relationship of the visual acuity and refractive error status in primary students using eyeglasses was improved.

  • PDF

A Study for Exact Spherical Diopter by Cross Cylinder Lens and Red·Green Card Method (크로스 실린더법과 적·녹검사를 이용한 정밀구면 굴절력에 관한 고찰)

  • Yoon, Kyounghan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.39-43
    • /
    • 1999
  • In this study, It obtained results that the exact spherical diopter to practice test by using Cross cyliner lens and Red Green Card method. In the test used to the 1750 eyes of middle and high school students. The results was as follows ; 1. Using Cross cylinder lens method, I tested a exact spherical diopter after accommodation. At -0.25 Dptr the ratio of spherical Dptr error limits were measured as 58% and at -0.75 Dptr they were oppeared as 1%, at -1.00 Dptr they are not measured. In this method, the error limits of exact spherical Dptr was 91% from 0 Dptr to -0.25 Dptr. 2. Using Red Green Card method, they were measured as 45% at -0.25 Dptr. and measured as 20% at -0.50 Dptr. From the result of these test, Cross cylinder lens method was a better detailed method than Red Green Card method.

  • PDF

Analysis of refraction status on the Presbyopia in Korea (한국인 노안 굴절상태 분석)

  • Kim, Douk-Hoon;Lee, Min-Ho
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1337-1344
    • /
    • 2019
  • Purpose. This study was the analyze the refractive status of presbyopia in Korea. Methods. The subjects was from November 2018 to October 2019, two hundred thirty four subjects( 117 male subjects, 117 female subjects; from 40-year old to 88-year old ) were performed in refraction test using the Auto-Refraction(Speed -K model, Japan). The myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)≤-0.50 diopters, SE ≥+1.00 D, cylinder error ≥0.75 D and SE difference≥1.00 D between binocular eyes, respectively. Results. The refractive status by spherical equivalent among all subjects was myopia 61.43%, astigmatism 86.86%, emmetropia 19.18%, anisometropia 12.07%, and hyperopia 18.54. The prevalence of myopia and astigmatism were much more common in male. However, The hyperopia and astigmatism were much more common in female. The prevalence of spherical equivalent was much common from -0.50 diopter to -5.00 diopter. On the other hand, the prevalence of astigmatism and myopia was much more than hyperopia in all subjects. There was a statistical significance between OD and OS of the female and male in the spherical equivalent power(p<.000). However, there was not statical significant between female and male of OD and OS in the spherical equivalent power(p<.070). On the other hand, The prevalence of againest axis in astigmatism was more common in all subjects. In ADD power for the near vision correction, the female was much more diopter than male. Conclusions. These results suggested that the analysis of the refractive status on the presbyopia in Korea can give the useful diagnosis data for the correction of visual acuity at near distance.

A Study of Abnormal Refraction Eye on Female Old Age (노인 여성의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.125-129
    • /
    • 2000
  • To fine understand the visual acuity of female old age. This study was researched the visual acuity test by the object and subject methods. The major findings was as follows: 1. The eye types were 80.94% positive for hyperopia. 13.86% for myopia and 5.19% for emmetropia respectively. 2. The anbormal refraction eye was positive for mixed astigmatism for 78.27%, myoptic com pound astigmatism (10.99%), simple presbyopia(4.97%), myopic simple astigmatism(2.88%), presbyopia compound astigmatism (1.57%), simple myopia(0.78%) and presbyopia simple astigmatism(0.52%). 3. The axis of astigmatism was 60.23% for against regular astigmatism. 22.73% for oblique astigmatism and 17.05% for regular astigmatism respectively. 4. On the total myopic spheric power, the -0.50 spheric equivalent ${\leq}-2.00$ was 90.2%, the -2.00${\leq}-6.00$ was 9.8%. 5. On the total presbyopic spheric power, the -0.50${\leq}-2.00$ was 80.252%, the -2.00${\leq}-6.00$ was 16.99% and 2.56% for anything over the 6.00 diopter. 6. On the astigmatic power, the $0.50{\geq}$ cylinder power${\geq}1.00$ was 69.35%,the 1.00> cylinder power ${\geq}2.00$ was 27.38%, and anything over the 2.00 cylinder diopter was 3.27%.

  • PDF

Optical constant of the reduced eye based on theoretical finite model eye (이론적 정밀모형안에 기초한 환산모형안의 광학상수)

  • 김상기
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.268-273
    • /
    • 2004
  • A finite model eye based on longitudinal spherical aberration is designed by an optimization method. Longitudinal spherical aberration for pupil diameter between 1 mm and 8 mm is graphed theoretically and compared with other model eyes. The chromatic dispersions are adjusted to fit experimentally observed chromatic aberration of the eye. This is a finite model eye with four a spheric refracting surfaces. It has an effective focal length of 15.842 mm. A designed reduced eye has an equivalent power of 63.12 Diopter, curvature radius of 5.281 mm, index of 1.33333, and axial length of 21.123 mm.

Characteristic and Fabrication of Auto-Lensmeter using with Personal Computer (PC를 이용한 자동렌즈메타의 제작 및 특성 연구)

  • Park, Moon Chan;Choi, Hai Jung;Chen, Ko Hsein;Cho, Dong Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.31-35
    • /
    • 2001
  • We have studied the auto-lensometer for several years in order to begin korean-made production of it and then developed the auto-lensmeter using with the personal computer. We introduce the most important principal of PSD device and the optical principal of measuring the power of the refraction of the lens by auto-lensometer and also explain the fabrication of the LED optical source system and PSD optical system. Finally, we found the power constant of our auto-lensmeter to be about 30 Diopter/mm.

  • PDF

A Study on the Ametropia of High School Students in Jeonbuk Province (전북 지역 고등학생 비정시에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun;Choe, Oh-Mok;Gang, Myoung-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.67-71
    • /
    • 2002
  • To investigate the ametropia and refractive error of 364 ametropic eyes en the 182 high school students in Jeonbuk provicne, the visual acuity test was performed by the object and subject method. The results were as follows. 1. The eye types were 85.7% positive for myopia, 6.6% for emmetropia and 7.6% hyperopia, respectively. 2. The abnormal refraction eyes were 30.8% positive for simple myopia, 58.5% for myopia compound astigmatism, 7.5% for myopia simple astigmatism, and 1.8% for simple hyperopia, 1.3% for hyperopia compound astigmatism, 1.9% for hyperopia simple astigmatism, respectively. 3. The axes of astigmatism were 78.7% for astigmatism with-the-rule, 13.9% for astigmatism against-the-rule, 7.4% for astigmatism oblique, respectively. 4. As for the astigmatic power, the 0.50 < cylinder < 1.00dptr was 60.0%, the 1.00 < cylinder < 2.00dptr was 29.2%, and anything over the 2.00cylinder dptr was 10.8%. 5. As for the equivalent spheric power of myopic abnormal refraction eyes, the -0.50 < spheric equivalent < -2.00 diopter was 64.6%, the -2.00 < spheric equivalent < -6.00 dptr was 29.1% and anything over the -6.00 dptr was 6%. 6. The equivalent spheric power of hyperopic abnormal refraction eyes was 50% anything under 2.00diopter and 50% for anything over the 2.00diopter.

  • PDF

Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center (안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정)

  • Kim, Hyojin;Park, Jee-Hyun;Park, Seon-A;Baek, Ji-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Measurement of the horizontal and vertical prism diopter was investigated which was occurred due to distance differences between the optical inter-centeral distance (OC) and the interpupillary distance (PD) of the prescribed glasses. Methods: We surveyed 96 subjects (192 eyes) at the average age of 21.56 years old. The PD was measured by using the PD measurement system (DONGYANG PD-85, Korea), and the OC of the glasses was measured by using the projective peak refractive power measurement system (TOPCON CL-200, Japan). The OH value was measured by using Penlight and the PD ruler. Results: The PD which had been measured by the PD system and the OC of the glasses revealed 78.1% of differences. 62.5% of the objects were base-in value prescribed glasses; 58.3% were out of permissible error. Only 8 subject showed concurrence between the prescribed glasses and the OH value, and 82.3% of the objects were induced vertical prism of over 1 (prism diopter). Conclusions: In order to improve the vision function of people who wear glasses, it is necessary to advance the accuracy of PD, OH measurement and making glasses as well.

Difference between Manifest Refraction (MR) and Cycloplegic Refraction (CR) with Age and Myopic Value (연령과 근시도에 따른 현성굴절검사와 조절마비굴절검사의 비교)

  • Jeong, Woo-Jae;Kang, Ji-Hun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate difference between manifest refraction (MR) and cycloplegic refraction (CR) with age and myopic value. Methods: Manifest and cycloplegic refractions were carried out on the patients of 229 myopic patients ($25.3{\pm}11.9$ years old). Results: The average results from a pre- and a postcycloplegic refraction showed a reduction of 0.19 D in myopia, 0.02 D in astigmatism and $1.85^{\circ}$ in astigmatism direction. Change of myopic value was higher in 30~40 age. Total 73 eyes of 229 patients who showed 0.50 diopter (D) in spherical, and a high degree of myopia group showed a higher discrepancy rate. Conclusions: The results found in the comparison of the value of the manifest refraction and cycloplegic refractions showed changes of myopic value was not significant with age of patient, but the group of high degree of myopia showed higher discrepancy rate.