• 제목/요약/키워드: diode laser

검색결과 1,017건 처리시간 0.031초

A Low-Crosstalk Design of 1.25 Gbps Optical Triplexer Module for FTTH Systems

  • Kim, Sung-Il;Park, Sun-Tak;Moon, Jong-Tae;Lee, Hai-Young
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.9-16
    • /
    • 2006
  • In this paper, we analyzed and measured the electrical crosstalk characteristics of a 1.25 Gbps triplexer module for Ethernet passive optical networks to realize fiber-tothe-home services. Electrical crosstalk characteristic of the 1.25 Gbps optical triplexer module on a resistive silicon substrate should be more serious than on a dielectric substrate. Consequently, using the finite element method, we analyze the electrical crosstalk phenomena and propose a silicon substrate structure with a dummy ground line that is the simplest low-crosstalk layout configuration in the 1.25 Gbps optical triplexer module. The triplexer module consists of a laser diode as a transmitter, a digital photodetector as a digital data receiver, and an analog photodetector as a cable television signal receiver. According to IEEE 802.3ah and ITU-T G.983.3, the digital receiver and analog receiver sensitivities have to meet -24 dBm at $BER=10^{-12}$ and -7.7 dBm at 44 dB SNR. The electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysis and measurement results, the proposed silicon substrate structure that contains the dummy line with $100\;{\mu}m$ space from the signal lines and 4 mm separations among the devices satisfies the electrical crosstalk level compared to a simple structure. This proposed structure can be easily implemented with design convenience and greatly reduce the silicon substrate size by about 50 %.

  • PDF

10 Gb/s XFP Transceiver용 Transmitter Optical Sub-assembly(TOSA)의 RF 설계/제작 및 주파수 특성 해석 (Design, Fabrication and Frequency Analysis of Transmitter Optical Sub-assembly for a 10 Gb/s XFP Transceiver)

  • 김동철;심종인;박문규;어영선
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.349-354
    • /
    • 2004
  • XFP(10 Gb/s Small Form Factor Pluggable) 트랜시버 모듈에 사용되는 광송신 서브어셈블리(TOSA: Transmitter Optical Sub-assembly)를 열적, 전기적 측면에서 설계, 제작 및 평가하였다. 저가격이며 소형인 TOSA를 제작하기 위해서 바이어스 티 및 정합저항등을 AlN서브마운트 위에 집적하였다. 10 Gb/s의 초고속 전기 신호의 입력을 위해 CPW형 마이크로파 전송로를 스템 구조체내에 도입하였다. 소자의 전기적 특성 분석을 위해 서브마운트내에 실장되는 각종 전기광학 부품들과 스템 구조체들을 고속회로 모델링 하였다. 제작한 TOSA의 특성평가를 통해, 85$^{\circ}C$에서 11 GHz 이상의 -3 dB 대역폭을 얻을 수 있었다.

$Er^{3+}$$Tm^{3+}$이 복합 첨가된 실리카 광섬유의 ASE 광원에 대한 특성 평가 (Characterization of amplified spontaneous emission light source from an $Er^{3+}$/$Tm^{3+}$co-doped silica fiber)

  • Jeong, Hoon;Oh, K.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.96-97
    • /
    • 2000
  • Incoherent broadband optical sources have been applied in various areas such as a light source for optical device characterization, fiber-optic gyroscopes$^{(1)}$ , and spectrum sliced light source in wavelength division multiplexing (WDM) system$^{(2)}$ . To utilize the inherent low loss in silica optical fibers, various types of incoherent light sources are being developed. Among the light sources, the amplified spontaneous emission (ASE) from a rare earth doped fiber has benefits in temperature stability, high output power, low polarization dependence over semiconductor diodes$^{(3)}$ . Recently erbium doped fibers (EDF) have been intensively researched for ASE sources as well as optical amplifiers$^{(4)}$ . The spectrum of ASE from an EDF, however, is limited in the 1520~1560 nm range in conventional configurations. In this letter we described a new broadband ASE source which included both the conventional ASE band of Er$^{3+}$ ion, 1520nm~1560nm and ASE band from Tm$^{3+}$ ions that extends the bandwidth further. For the first time, to the best knowledge of authors, a fiber ASE source based on the energy transfer between Er$^{3+}$ and Tm$^{3+}$ ions in the range of 1460~1550 nm, has been demonstrated using a single 980nm pump laser diode. (omitted)omitted)

  • PDF

Time-resolved PIV와 POD기법을 이용한 유량에 따른 단일노즐 버블링 유동 특성에 관한 연구 (Characteristics of Bubble-driven Flow with Varying Flow Rates by Using Time-resolved PIV and POD Technique)

  • 이승재;김종욱;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제6권2호
    • /
    • pp.14-19
    • /
    • 2008
  • In this paper, the recirculation flow motion and mixing characteristics driven by air bubble flow in a rectangular water tank is studied. The Time-resolved PIV technique is adopted for the quantitative visualization and analysis. 532 nm Diode CW laser is used for illumination and orange fluorescent particle images are acquired by a PCO 10bit high-speed camera. To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is changed from 2 l/min to 4 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by the POD analysis technique. It is observed that the large scale counterclockwise rotation and main vortex is generated in the upper half depth from the free surface and one quarter width from the sidewall. When the flow rates are increased, the main vortex core is moved to the side and bottom wall direction.

DWDM 광통신용 50GHz 내장형 파장안정화 모듈 제작 (Fabrication of 50GHz internal wavelength locker module for DWDM applications)

  • 최광성;박흥우;박준희;최병석;이종현;윤호경;엄용성;문종태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.198-202
    • /
    • 2003
  • Tunable laser diode module with 50GHz-spacing internal wavelength locker was developed. Angle tilting dependency on FSR and peak wavelength shift and the proper initial tilting angle was calculated. By tilting the etalon, the response of the internal wavelength locker module was tuned. As a result, the fabricated internal wavelength locker module showed good performance over 62 channels.

  • PDF

비축대칭 Glass Array Lens의 설계 및 개발 (Design and Development of Asymmetry Glass Array Lens)

  • 박순섭;황연;이기용;김건희;원종호
    • 한국정밀공학회지
    • /
    • 제25권12호
    • /
    • pp.39-46
    • /
    • 2008
  • Asymmetric glass lens core for portable projection optic system was designed and simulated. And it was machined by newly developed non-rotational ultra precision grinding method. With the designed lens data which optimized for multi-collimation, we generated the we core surface data. Mold pressing conditions analyzed by FEM. In the machining process, ground profile errors were compensated based on measured data, minimized feed rate and depth of cut. The deviations of machined core profile were acceptable level for glass mold press. Mold pressed glass array lens was coated with $SiO_2\;and\;Ta_2O_5$ for anti-reflection.

마이크로 레이저 형광 여기법을 이용한 미세채널 내부에서의 산소 확산에 대한 정량적 가시화 (Quantitative Visualization of Oxygen Transfer in Micro-channel using Micro-LIF Technique)

  • 천쥐안;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2012
  • In the present study, oxygen transfer process across gas-liquid interface in a Y-shape micro-channel is quantitatively visualized using the micro laser induced fluorescence (${\mu}$-LIF) technique. Diffusion coefficient of Oxygen ($D_L$) is estimated based on the experimental results and compared to its theoretical value. Tris ruthenium (II) chloride hexahydrate was used as the oxygen quenchable fluorescent dye. A light-emitting diode (LED) with wavelength of 450 nm was used as the light source and phosphorescence images of fluorescent dye were captured by a CMOS high speed camera installed on the microscope system. Water having dissolved oxygen (DO) value of 0% and pure oxygen gas were injected into the Y-shaped microchannel by using a double loading syringe pump. In-situ pixel-by-pixel calibration was carried out to obtain Stern-Volmer plots over whole flow field. Instantaneous DO concentration fields were successfully mapped according to Stern-Volmer plots and DL was calculated as $2.0675{\times}10^{-9}\;m^2/s$.

Er과 Yb이 첨가된 인산염 유리의 K 이온교환 공정을 통한 증폭용 광도파로 제조 (Fabrication of Er/Yb co-doped phosphate glass waveguides by potassium ion exchange)

  • 김덕준;신장욱;박상호;김태흥;심재기;성희경
    • 한국광학회지
    • /
    • 제11권3호
    • /
    • pp.202-205
    • /
    • 2000
  • Er과 Yb이 첨가된 인산염 유리를 KNO3 응용액에 담구는 1단계 이온교환 공정을 통하여 채널 도파로를 제조하고자 하였다. 이온교환시 반응기 내부에 산소를 흘려줌으로서 인산염 유리의 열학한 화학적 내구성에서 비롯되는 유리 도파로 표면의 손상을 억제할 수 있었다. 제조된 도파로의 $1.5{\mu}m$ 신호광에 대한 증폭특성을 평가한 경과, 이온교환 공정 최적화 작업을 거친 45nm도파로의 경우, 2개의 980nm LD를 사용하는 양방향 펌핑시 160mW 파워에서 7.5dB의 순이득을 얻을 수 있었다.

  • PDF

보이스 코일 모터를 이용한 미세 하중 및 위치 결정 기구의 개발 (Development of Small Loading and Positioning Device using VCM)

  • 권기환;오승환;조남규;윤준용
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.64-72
    • /
    • 2003
  • This paper presents a small loading and positioning device using VCM (voice coil motor). The developed device consists of a VCM-based linear actuating system, a capacitance displacement sensor and a cantilever deflection sensing system. The trust force of the VCM proportional to applied current moves the column supported on two pairs of parallel leaf springs. The infinitesimal displacement of moved column is detected by capacitance displacement sensor with a resolution of 0.1nm and a repeatability of 1nm. Also, a micro cantilever with known stiffness (200N/m), which is mounted on the end of the column, is used as a force sensor to detect the load applied to a specimen. After the cantilever contacts with the specimen, the deflection of cantilever and the load applied to the specimen are measured by using an optical lever system which consists of a diode laser, a mirror and a PSD (position sensitive detector). In this paper, an experimental system was constructed and its actuator and sensing parts were tested and calibrated. Also, the constructed system was applied to the indentation experiment and the load-displacement curve of aluminum was obtained. Experimental results showed that the developed device can be applied for performing nano indentation.

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF