• Title/Summary/Keyword: diode laser

Search Result 1,017, Processing Time 0.025 seconds

The effect of thickness on luminous properties of ceramic phosphor plate for high-power LD (고출력 LD 용 형광체 세라믹 플레이트의 두께에 따른 광학 특성)

  • Ji, Eun Kyung;Lee, Chul Woo;Song, Young Hyun;Jeong, Byung Woo;Jung, Mong Kown;Yoon, Dae-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.2
    • /
    • pp.80-83
    • /
    • 2016
  • In the present paper, garnet structured $Y_3Al_5O_{12}:Ce^{3+}$ (YAG : Ce) ceramic phosphor plate (CPP) for high power laser diode (LD) was prepared and optical properties were analyzed. We synthesized monodispersed spherical nano-sized YAG : Ce particles by liquid phase method, fabricated phosphor ceramic plate with the addition of $Al_2O_3$. $75{\mu}m$ and $100{\mu}m$ thick YAG : Ce CPPs were compared in terms of the factors of conversion efficacy, thermal quenching, luminance and correlated color temperature (CCT). In conclusion, conversion efficacy decreased by 25 % in both samples and $100{\mu}m$ thick sample provides better optical properties of thermal quenching, maximum light conversion efficacy and maximum luminance value.

Measuring System for Impact Point of Arrow using Mamdani Fuzzy Inference System (Mamdani 퍼지추론을 이용한 화살의 탄착점 측정 시스템)

  • Yu, Jung-Won;Lee, Han-Soo;Jeong, Yeong-Sang;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.521-526
    • /
    • 2012
  • The performance of arrow from a manufacturing process depends on arrow's trajectory(archer's paradox) and intensity of an impact points. Especially, when conducting a shooting experiment over and over in the same experiment condition, the intensity of impact point is an objective standard to judge the performance of the arrow. However, the analysis method for the impact point is not enough, a previous research of the arrow's performance has been focused on a skill to optimize a manufacturing variables(feathers of an arrow, barb of an arrow, arrow's shaft, weight, external diameter, spine). In this paper, We propose measurement system of arrow's impact point with Mamdani fuzzy inference system and similarity of polygon for automation of impact point's measurement. Measuring the impact point data of the arrow moving with a high speed(approximately 275km/h) by using line laser and photo diode array, then the measured data are mapped to arrow's impact point with fuzzy inference and similarity of polygon.

A Study on the Seam Tracking by Using Vision Sensor (비전센서를 이용한 용접선 추적에 관한 연구)

  • 배철오;김현수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1374-1380
    • /
    • 2002
  • Recently, the use of Robot increase little by little for the purpose of developing a welding quality and productivity in the welding part. It is more important to contact the seam for arc welding before moving a welding robot. There are two types of method to contact the seam namely contact and non-contact type largely. In this paper, image processing sensor(a kind of non-contact sensor) is concerned to track the seam by using laser diode and CCD camera. A structured laser diode's light illuminated on the weld groove and the reflected shape is introduced by CCD camera. The image board captures this image and software analyzes this image. The robot is moved and welded exactly as acquired image X-Y data is changed with robot's X-Y value. Also, most of seam tracking are considered by changing the program simply in case of the different weld groove of plane surface.

Implementation of Marine Optical Sensor System Using A Line-CCD (Line-CCD를 이용한 수중광학 센서 시스템의 구현)

  • Jeong, Ui-Seok;Lee, Dong-Ho;Lee, Kyoung-Woon;Lim, A-Ram;Jeong, Jae-Wook;Park, Jung-Ho
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.244-249
    • /
    • 2010
  • We fabricated optical sensor system that take a measurement particles using a line-CCD in ocean. To measure particles, we used 680nm laser diode which is appropriate. we tested to operate optical system in water tank and ocean. It has performance that detected signal of sensors transfer microprocessor, FPGA as long as move up and down it's motion. The system algorithm also analysis output -pressure, temperature, particle numbers in depth.-For experiment, our particle sensor system has high accuracy counter. therefore, we proposed that a line-CCD is available on optical sensor system in ocean.

Optical Clock Recovery from RZ and NRZ data using a Multi-Section Laser Diode with a DFB Reflector (DFB 반사기가 집적된 다중전극 레이저 다이오드를 이용한 RZ 및 NRZ 데이터 신호의 광클럭 재생)

  • Jeon, Min-Yong;Leem, Young-Ahn;Kim, Dong-Churl;Sim, Eun-Deok;Kim, Sung-Bock;Park, Kyung-Hyun;Yee, Dae-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.68-74
    • /
    • 2006
  • We have extracted an optical clock signal from a return-to-zero(RZ) pseudorandom bit sequence(PRBS) and non-return-to-zero(NRZ) PRBS data in a pulsation multi-section laser diode with DFB reflector. The ms timing jitter achieved less than 1 ps for the input 11.727 Gbit/s RZ PRBS and NRZ PRBS data. The PRE data wasconverted from the NRZ data using an NRZ to pseudo-return to zero(PRZ) converter module. The optical clock was extracted from the PRZ data which contains the clock components. Although the input PRZ data gives a timing jitter of 2 ps, the extracted clock has timing jitter of ${\~}$1 ps.

The Study of the Optical CT Temperature Characteristic Using Faraday Effects (Faraday효과를 이용한 광CT의 온도특성에 관한 연구)

  • Jeon, Jeo-Il;Heo, Soon-Young;Park, Won-Zoo;Lee, Kwang-Sik;Kim, Jung-Bae;Kim, Min-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.136-142
    • /
    • 2005
  • In this paper, we wrote about the basic experimentation of Optical CT's temperature characteristic to measure high-current in a super-high-voltage electric power equipment which is using Faraday effect. We used the 1310[nm] Laser Diode as the light source and PIN Photodiode as receiver. For the transmission line of light, we used 30[m] single mode fiber which could maintain the state of polarization in the optical fiber. For the experiment, the temperature transformation device make by aluminium. the The range of current was from 400[A] and 1300[A] and the range of temperature was from $-40[^{\circ}C]\;to\;50[^{\circ}C]$. In a same experimental condition, magnitude increased input current increase follow by increasing proportion of input current.

A Study on the Seam Tracking by Using Image Processing (영상정보처리에 의한 용접선 추적에 관한 연구)

  • 배철오;박영산;이성근;김윤식;안병원;김현수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.460-464
    • /
    • 2001
  • Recently, the use of Robot increase little by little for the purpose of developing a welding quality and productivity in the arc welding part. It is more important to contact the seam for arc welding before moving a welding robot. There are two types of method to contact the seam namely contact and noncontact type largely In this paper, image processing sensor(a kind of non-contact sensor) is concerned to track the seam by using laser diode and CCD camera. A structured laser diode's light illuminated on the weld groove and the reflected shape is introduced by CCD camera. The image board captures this image and software analyzes this image. The robot is moved and welded exactly as acquired image X-Y data is changed with robot's X-Y value. Also, most of seam tracking are considered by changing the program simply in case of the different weld prove of plane surface.

  • PDF

Photodynamic Inactivation of Moraxella catarrhalis (Moraxella catarrhalis의 광역학적 비활성화)

  • Hong, Seong-No;Kwon, Pil-Seung;Kim, Dae-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.19-24
    • /
    • 2007
  • The aim of this study was to evaluate the bacterial effects of Moraxella catarrhalis in otitis media with effusion (OME) by photodynamic therapy (PDT). Bacterial suspensions (10000 CFU/mL) were prepared. The colony forming units (CFU) of Moraxella catarrhalis have been measured after an application of photogem plus 632 nm diode laser irradiation. One ml of the bacterial suspensions have been incubated in the dark for 3h with various concentrations of photogem ($0.625{\sim}5.0_{\mu}g/mL$) and then irradiated with 632 nm diode laser ($15J/cm^2$). After, the PDT Moraxella catarrhalis suspensions ($50{\mu}L$) were inoculated on chocolate agar plate and cultured in the dark at $37^{\circ}C$, 5% $CO_2$ condition for 18h. The colony forming units off the bacteria were measured. Also transmission electron microscopy (TEM) was employed to evaluate the effect of otitis media pathogens by PDT. The nucleus of Moraxella catarrhalis was stained using green fluorescent nucleic acid dye thiazole orange and the fluorescence intensity of the nucleus was measured by flow cytometry. The PDT was effective in killing Moraxella catarrhalis at the photogem dose of $5.0_{\mu}g/mL$, respectively, As assessed by flow cytometry analysis the fluorescence intensity of the nucleus got lower after PDT. TEM result appeared to able to cause damage to the bacterial membranes. On the basis of these findings, bacterial photodynamic therapy with photogem can be considered to be a promising new therapeutic approach for OME.

  • PDF

Evaluation of Static Error Signal for Super Slim Optical Pick-up (초소형 광 픽업의 정적 오차 신호 검출)

  • Kang, S.M.;Cho, E.H.;Sohn, J.S.;Kim, W.C.;Park, N.C.;Park, Y.P.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.115-120
    • /
    • 2005
  • As a popularity of a portable digital device such as a cellular phone, a digital camera and a MP3 player is spreading, the demand of the mobile storage device increases rapidly. A bluray technology using 405nm laser diode and objective lens having high NA(Numerical Aperture), 0.85, satisfies a miniaturization and a high capacity which are the requirements of the portable device. To develop SFFOP(small form factor optical pickup), it is prerequisite to minimize the number of optical components and establish evaluation and assembly method of micro optical pickup system as well as mass production method of micro optical component. To minimize optical elements of optical pickup, there have been many researches to use P-HOE(Polarized Holographic Optical Element) due to its extremely small size and versatile function. However, P-HOE is handled and assembled very accurately in SFFOP. In this paper, static error signal detection method is developed for an alignment of P-HOE in SFFOP. Using developed static error signal detection method, P-HOE can be aligned very accurately with real time result of static error signals of pickup such as FES(focusing error signal) and TES(Tracking Error Signal). The developed static error signal detection method is verified by the evaluation of commercialized DVD Pickup. And finally. developed static error signal detection method is applied for the assembly of P-HOE in SFFOP system satisfies specification of BD(Blu-ray Disk).

  • PDF

Operational and Thermal Characteristics of a Microchip Yb:YAG Laser (마이크로 칩 Yb:YAG 레이저의 동작 및 열적 특성)

  • Moon, Hee-Jong;Hong, Sung-Ki;Lim, Chang-Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.96-101
    • /
    • 2011
  • Operational and thermal characteristics of a thin disk Yb:YAG crystal with a thickness of 0.8 mm were studied using as a pumping source a fiber-coupled 930 nm laser diode. The heat generated in the crystal was dissipated by placing both surfaces in contact with copper plates with central hole, and the dependence of the temperature change in the illuminated spot on hole size was investigated by measuring the spectral change of the lasing peaks. The slope efficiency and optical-to-optical efficiency with respect to the LD pump power were as high as 42.2% and 34.8%, respectively. The temperature at the illuminated spot increased with diode current and with increasing hole size of the copper plate. When the hole size considerably exceeded the crystal thickness, the temperature rise deviated from the linear increase at high pump power.