• 제목/요약/키워드: dilution method

검색결과 816건 처리시간 0.031초

디젤 극미세입자 개수 농도 측정시 Volatile Particle 생성을 억제할 수 있는 희석방법에 관한 실험적 연구 (An Experimental Study of Dilution Methods for Preventing Volatile Particle Generation during Measurement of Diesel Particle Number Concentration)

  • 임태호;김홍석;조형문;이진욱;정용일;전흥신
    • 한국자동차공학회논문집
    • /
    • 제17권5호
    • /
    • pp.67-73
    • /
    • 2009
  • Recently, Europe decided to start the regulation of diesel engine nanoparticles because of its well known adverse health effects. The diesel nanoparticles can be classified as solid carbon particles and volatile particles. The volatile particles generates during dilution process by condensation of gas phase volatile compounds such as hydrocarbon. The new nanoparticle regulation considers only solid particles because of difficulty of measurement of volatile particles. The aim of this study is to suggest a proper dilution method that prevent the volatile particle generation. As a result, it is found that the $1^{st}$ dilution air temperature should be above $120^{\circ}C$ in order to prevent volatile particle generation effectively. It is also found that the volatile particles can be removed effectively in the evaporation tube by the increase of evaporation tube temperature. But when exhaust gas is hot enough (>$190^{\circ}C$, in this study) and it is diluted in the first diluter with high temperature air (>$120^{\circ}C$), removal phenomenon of volatile particles by increasing of evaporation tube temperature can not be seen. It means that there are no volatile particles in the diluted exhaust gas. Additionally, dilution ratio is not an important factor for volatile particle generation compared with dilution air temperature or evaporation tube temperature.

CH4공기 제트 확산화염에서 CO2 첨가에 따른 단일 와동의 동적거동에 관한 연구 (An Investigation on Dynamic Behaviors of Single Vortex with CO2 Dilution in a CH4-Air Jet Diffusion Flame)

  • 황철홍;오창보;이대엽;이창언
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1209-1219
    • /
    • 2003
  • The dynamic behaviors of the single vortex interacting with $CH_4-Air$ jet diffusion flame are investigated numerically. The numerical method is based on a predict-corrector scheme for a low Mach number flow. A two-step global reaction mechanism is adopted as a combustion model. Studies are conducted in fixed initial velocities for the three cases according as where $CO_2$ is added; (1) without dilution, (2) dilution in fuel stream and (3) dilution in oxidizer stream. A single vortex is generated by an axisymmetric jet, which is made by an impulse of a cold fuel when a flame is developed entirely in a computational domain. The simulation shows that $CO_2$ dilution in fuel stream results in somewhat larger vortex radius, and greater amount of entrainment of surrounding fluid than in other cases. Thus, the dilution of $CO_2$ in fuel stream enhances the mixing in single vortex and increases the stretching of the flame surface. The budgets of the vorticity transport equation are examined to reveal the mechanism of vortex formation when $CO_2$ is added. It is found that, in the case of $CO_2$ dilution in fuel stream, the vortex destruction due to volumetric expansion and the vortex production due to baroclinic torque are more dominant than in other cases.

희석 파라미터법에 의한 철광석 중 철과 티탄의 X-선 형광분석 (X-Ray Fluorescence Analysis of Iron and Titanium in Iron Ores by Dilution Parameter Method)

  • 김영상;이종욱
    • 대한화학회지
    • /
    • 제25권3호
    • /
    • pp.183-189
    • /
    • 1981
  • 철광석 중에서 주성분 원소들인 철과 티탄올 희석 파라미터법(dilution parameter method)을 이용한 X-선 형광분석법으로 분석하였다. 조성이 비슷한 표준시료와 분석시료 각각에 적당한 희석제($ZrO_2$)를 가하여 적당한 비율 (1:1, 1:2등)로 희석시켜서 원하는 원소의 형광 X-선 세기를 측정하여 다음 식으로 희석 파라미터를 구한다.$Pa=\frac{\frac{I_{as}}{(I_{as})_d}}{D-1}{^{-1}}$이들 파라미터를 이용하여 표준시료와 분석시료의 matrix effect 차이를 보정하여 표준검량선 없이 정량 분석하였다.$W_a=W_a^*{\cdot}{\frac{I_as}{I_{as}^*}{\cdot}\frac{P_a^*}{P_a}$여기서, *는 표준시료를 표시한다. 분석결과는 습식법으로 정량한 값들과 잘 일치하고 재현성도 좋음을 보여주었다.

  • PDF

기체크로마토그래피/동위원소 희석 질량분석법을 이용한 토양 중 폴리브롬화 디페닐에테르의 분석법 (Determination of Polybrominated Diphenyl Ethers(PBDEs) in Soil using Gas Chromatography/Isotope Dilution Mass Spectrometry)

  • 나윤철;장윤석;김해동;홍종기
    • 분석과학
    • /
    • 제17권1호
    • /
    • pp.29-36
    • /
    • 2004
  • 본 연구에서는 토양중에 존재하는 폴리브롬화 디페닐에테르 (polybrominated diphenyl ethers, PBDEs)를 동위원소희석법을 이용한 기체크로마토그래피/질량분석기-선택이온검색법에 의해 검출하는 분석방법을 소개하였다. 토양 중 PBDEs는 속실렛 장치로 추출하고 실리카와 플로리실 흡착제를 이용한 고체상 추출법을 비교하였다. 정제 후 추출물은 기체크로마토그래피/질량분석기-선택이온검색방법으로 분석하였으며, 동위원소로 치환된 4종의 PBDEs를 내부표준물질로 이용한 동위원소 희석법으로 8종의 PBDEs를 정량하였다. 속실렛추출 후 플로리실과 실리카 카트리지를 통한 회수율은 각각 30.8~110.8%, 44.4~110.7%이었다. 이 분석법의 검출한계는 0.04~0.3 ng/g로 나타났다.

Antimicrobial efficacies of alkaline disinfectant solution and commercial disinfectants against Brucella ovis

  • Yoo, Jong-Hyun
    • 한국동물위생학회지
    • /
    • 제32권4호
    • /
    • pp.347-351
    • /
    • 2009
  • Bruella spp. involves a considerable danger of public health and farm animal industry. In this study, we assessed the disinfection efficacy of alkaline disinfectant solution and three commercial farm disinfectants (quaternary ammonium compound, sodium dichloroisocyanurate, potassium monopersulphate/sodium dichloroisocyanurate) against Brucella ovis. A bactericidal efficacy test by broth dilution method was used to determine the lowest effective dilution of selected disinfectants following exposure to test bacteria for 30 minutes at $4^{\circ}C$. Disinfectants and test bacteria are diluted with distilled water (DW), hard water (HW) or organic matter suspension (OM) according to treatment condition. Three commercial disinfectant showed excellent antimicrobial activity (up to dilution of $\times200$ in OM treatment). Alkaline disinfectant solution demonstrated favorable bactericidal efficacy against B. abortus (at dilution of $\times20$ in OM treatment). Three commercial farm disinfectants possess excellent efficacy against B. ovis. Alkaline disinfectant solution has lower potency than commercial farm disinfectant but could help to limit the spread of brucellosis.

Estimation of Relative Potency with the Parallel-Line Model

  • Lee, Tae-Won
    • 응용통계연구
    • /
    • 제25권4호
    • /
    • pp.633-640
    • /
    • 2012
  • Biological methods are described for the assay of certain substances and preparations whose potency cannot be adequately assured by chemical or physical analysis. The principle applied through these assays is of a comparison with a standard preparation to determine how much of the examined substance produces the same biological effects as a given quantity (the Unit) of the standard preparation. In these dilution assays, to estimate the relative potencies of the unknown preparations to the standard preparations, it is necessary to compare dose-response relationships of standard and unknown preparations. The dose-response relationship in the dilution assay is non-linear and sigmoid when a wide range of doses is applied. The parallel line model (applied to the dose region with the steepest slope) is used to estimate the relative potency. In this paper, the statistical theory in the parallel line model is explained with an application to a dilution assay data. The parallel line method is implemented in a SAS program and is available at the author's homepage(http://cafe.daum.net/go.analysis).

공기희석관능법과 기기분석법에 기초한 악취감지기술의 연계성 비교: 산단지역 및 음식물 부패시료를 중심으로 (A Comparative Study of Odors between Air Dilution Sensory Test and Instrumental Detection Method Using Industrial and Food Waste Samples)

  • 박신영;김기현
    • 한국대기환경학회지
    • /
    • 제23권4호
    • /
    • pp.420-429
    • /
    • 2007
  • In this study, we attempted to evaluate the relationship between air dilution sensory test and instrumental detection method for individual odorous compound. For the purpose of our comparative study, we conducted the analysis of malodor on total of 46 samples collected from both industrial and food waste sectors using the two independent approaches. The results of instrumental analyses were explained after modification to several parameters such as: the sum of odor concentration (SOC), sum of odor quotient (SOQ) and sum of odor intensity (SOI). When we compared dilution ratio values (DRV) of threshold limit (TL) with the modified instrumental data sets, pearson coefficient of SOC, SOQ, and SOI were 0.556 (p=5.83E-05), 0.911 (p=9.64E-19) and 0.847 (p=8.93E-14), respectively. The results of this study thus suggest that the DRV of TL sensitively reflects odor strength measured intuitive.

플라즈마 화학증착법으로 제작한 미세결정질 실리콘 박막 특성에 관한 연구 (A Study on Characteristics of Microcrystalline-silicon Films Fabricated by PECVD Method)

  • 이호년;이종하;이병욱;김창교
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.848-852
    • /
    • 2008
  • Characteristics of microcrystalline-silicon thin-films deposited by plasma-enhanced chemical-vapor deposition (PECVD) method were studied. There were optimum values of RF power density and $H_2$ dilution ratio $(H_2/(SiH_4+H_2))$; maximum grain size of about 35 nm was obtained at substrate temperature of 250 $^{\circ}C$ with RF power density of 1.1 W/$cm^2$ and $H_2$ dilution ratio of 0.91. Larger grain was obtained with higher substrate temperature up to 350 $^{\circ}C$. Grain size dependence on RF power density and $H_2$ dilution ratio could be explained by etching effects of hydrogen ions and changes of species of reactive precursors on growing surface. Surface-mobility activation of reactive precursors by temperature could be a reason of grain-size dependence on the substrate temperature. Microcrystalline-silicon thin-films that could be used for flat-panel electronics such as active-matrix organic-light-emitting-diodes are expected to be fabricated successfully using these results.

Effect of Water Adulteration on the Rheology and Antibacterial Activities of Honey

  • ANIDIOBU, Vincent Okechukwu
    • 식품보건융합연구
    • /
    • 제8권5호
    • /
    • pp.11-20
    • /
    • 2022
  • Honey was diluted with different percentages of water and was analysed rheologically at room temperature of 27℃. The rheological profiles of pure and impure honey samples were measured at low shear rates (0.01-4.16s-1). This work developed a structural kinetic model, which correlated well with the rheological data. The new model was used to categorise honey samples using their average molecular weights as one of the distinctive properties. Also, the kinetics order in the new model predicts the number of active components in the "honey" undergoing deformation. Honey produced third order kinetics to depict the monomers, oligomers and water content in honey. Pure honey exhibits peculiar non-Newtonian rheological behaviour. The behaviour of water is Newtonian. Dilution of honey with different percentages of water turns the resulting fluid Newtonian from 10% dilution with water. This study analysed the antibacterial activities of honey and serially adulterated samples against Staphylococcus aureus and Pseudomonas aeruginosa. The antibacterial analyses of honey were conducted using Kirby Bauer's well diffusion method. The results indicated that pure honey exhibited a zone of inhibition against both organisms. Also, the diameter of the zone of inhibition decreased with increasing dilution of honey, suggesting a correlation with the rheological method.

흑연로 원자흡수분광법에 의한 혈액중 카드뮴 정량분석 (A Comparative Analysis of Whole Blood Cadmium by Atomic Absorption Spectrophotometry with a Graphite Furnace)

  • 박종안;오혜정;이종화
    • 한국산업보건학회지
    • /
    • 제6권2호
    • /
    • pp.301-312
    • /
    • 1996
  • This study was performed to search a optimal analyzing method of cadmium in whole-blood. Cadmium was determined by graphite furnace atomic absorption spectrometry(GFAAS). We investigated the effect of ashing temperature on the absorbance of cadmium in a simple dilution(ten-fold) method with triton X-100 and matrix modifier methods treated with $NH_4H_2PO_4$(1 and 3%) and $Pd(NO_3)_2$(0.00l and 0.005%) as matrix modifier. We also compared the reported reference values of standard blood with values resulted from optimal analyzing conditions of this study. In case of a simple dilution method, when ashing temperature was set at $450^{\circ}C$, the absorbance of sample and background were $0.334{\pm}0.012$ and $1.382{\pm}0.245$, respectively. Background level was higher than the value(0.8) that can be corrected by $D_2$ background correction method. As ashing temperature was rised to $500^{\circ}C$, the absorbance of sample and background were $0.178{\pm}0.008$ and $0.711{\pm}0.223$ respectively. The higher ashing temperature($450^{\circ}C-650^{\circ}C$) was, the lower the absorbance of sample was. In case of a matrix modifier method with $NH_4H_2PO_4$(1 and 3%), when ashing temperature was rised from $500^{\circ}C$ to $650^{\circ}C$, the absorbance of sample slightly changed. The absorbances of sample at $600^{\circ}C$ were $0.230{\pm}0.017$ and $0.137{\pm}0.012$, respectively. These values were larger than that of simple dilution method. But the absorbance of background was higher than the level that can be corrected by $D_2$ method. In case of a matrix modifier method with $Pd(NO_3)_2$(0.001 and 0.005%), the absorbance of sample and background were higher than those of other methods and were stable and reproducible. When ashing temperature was over $550^{\circ}C$, the absorbance of sample was significantly decreased. In case of 0.005% $Pd(NO_3)_2$ carbon residue remained in graphite tube affected the absorbance of sample and background. From these results, We propose that in case of a simple dilution(ten-fold) method with triton X-100 ashing temperature must be maintained below $400^{\circ}C$. In order to diminish the absorbance of background, the alternative method is attenuation of injection volume or multiplication of dilution ratio. We recommend $Pd(NO_3)_2$ than $NH_4H_2PO_4$ as a matrix modifier. In case of a matrix modifier method with $Pd(NO_3)_2$ ashing temperature might be maintained below $550^{\circ}C$.

  • PDF