• 제목/요약/키워드: digital relay

검색결과 272건 처리시간 0.022초

순환형 최소자승법을 이용한 송전선로의 고장점 추정 알고리즘 (The Fault Location Estimation Algorithm in Transmission Line Using a Recursive Least Square Error Method)

  • 윤창대;이종주;정호성;신명철;최상열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.203-205
    • /
    • 2002
  • This paper presents the fault location estimation algorithm in transmission line using a recursive least square error method (RLSE). To minimize the computational burden of the digital relay a RLSE approach is used. Computer simulation results of the RLSE algorithm seem promising, indicating that it should be considered for further testing and evaluation.

  • PDF

GUI를 이용한 교육 /훈련용 디지털 계전기 시뮬레이터의 개발 (The Development of the Digital Relay Simulator for Education and Training using GUI)

  • 김동수;김인수;여상민;김철환;김응모;이칠기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.180-182
    • /
    • 2001
  • 기존의 디지털 계전기 교육/훈련 방법은 적절한 교육용 소프트웨어 및 기기의 부재로 인해 교육을 받는 훈련생들을 단기간 내에 이해시키는데 어려움이 있었다. 본 연구의 목적은 GUI 환경에서 다양한 모의 고장 발생, 모의 고장 시나리오의 입력, 편집 수정, 삭제가 가능하고 디지털 계전기의 교육/훈련 기능과 함께 훈련 결과의 평가와 훈련일지의 작성 기능을 포함하는 디지털 계전기 시뮬레이터의 개발이다. 본 논문에서는 고장종류, 고장발생 각, 고장거리, 데이터의 샘플수에 따라 EMTP를 이용하여 모의한 후, 디지털 신호 처리를 이용하여 직류 성분과 고조파 성분을 제거하고, 기본파 성분을 추출한다. 그리고 추출된 데이터를 사용하여 임피던스 궤적을 도시하고. 그 결과를 사용자에게 보여주도록 하였다. 특히, GUI 환경으로 구성하여 알고리즘의 수행과정을 보다 쉽게 이해하고. 사용할 수 있도록 함으로써, 교육/훈련의 효과가 극대화되도록 하였다.

  • PDF

교육용 디지털 릴레이 시뮬레이터 개발에 관한 연구 (A Study on the Development of the Digital Relay Simulator for Education)

  • 김인수;김형진;안상필;이종포;여상민;강윤식;안상민;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.98-100
    • /
    • 2000
  • 디지털 릴레이 알고리즘을 교육시키는 것은 전력계통의 관심사중의 하나이었다. 그러나 전력계통의 보호계전 알고리즘의 비공개성 때문에, 디지털 릴레이 시뮬레이터에 의한 전력계통의 디지털 릴레이 알고리즘을 교육/훈련시키는 데 어려움이 있었다. 그러므로, 송전선로의 디지털 계전 알고리즘을 시뮬레이션 할 수 있는 새로운 디지털 릴레이 시뮬레이터가 필요하다. 본 연구는 이러한 요구조건에 맞는 교육/훈련용 디지털 릴레이 시뮬레이터를 소프트웨어(프로그래밍 언어)에 의해 디지털 릴레이의 물리적 이론적 메커니즘을 바탕으로 개발하는 것이 목적이다.

  • PDF

실시간 디지털 시뮬레이터를 이용한 전류차동계전기 개발시험 (A Testing Method of Current Deferential Relay Using RTDS)

  • 김태원;홍순천;장병태;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1397-1400
    • /
    • 1999
  • The function of newly developed equipments must be verified in real power system before they put into operation. However, it is hard to test them in real power system due to the possibility of abnormal operation. In this paper, test method for new relays is developed in order to simulate their function in real power system using RTDS (Real Time Digital Simulator) and the simulation results show the capability of method.

  • PDF

적응 뉴로퍼지 추론시스템(ANFIS)을 이용한 송전선로에서의 고장검출 (A Fault Detection of Transmission Line using ANFIS)

  • 김희수;유창완;홍대승;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1082-1084
    • /
    • 1999
  • A fault detection of power system must be fast and correctly over input signal without relation to any disturbance. But, it is difficult to detect fault state for digital relay comparison of fault perfectly. In this Paper, we measure each Phase current and infer type of fault using ANFIS(Adaptive Neuro-Fuzzy Inference System).

  • PDF

ATM 통신망의 성능관리를 위한 시스템구조 (System Architecture for Performance Management in ATM Network)

  • Hyeog In Kwon
    • 한국전자거래학회지
    • /
    • 제6권2호
    • /
    • pp.25-38
    • /
    • 2001
  • ATM is the transport method for the broadband integrated services digital networks(B-ISDN). It may replace existing LAN, MAN and WAN technologies such as CSMA/CD, FDDI, Frame relay, X.25, etc. But it is more complicate than existing network technologies. One of the main difficulties in ATM network is performance management. Specifically, the problems are evaluating the performance and tuning the values of the performance parameters, The goal of this paper is to introduce a system architecture designed for ATM network performance management, The major ingredients of the system are generic performance parameters In be measured from ATM network, performance evaluation models and decision criteria concerning the network performance. In this paper, general requirements for performance management application in ATM network are discussed.

  • PDF

Internet Gateway System과 Call Simulator 구현 (Implementation of Internet Gateway System and Call Simulator)

  • 이응주;이찬희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(3)
    • /
    • pp.161-164
    • /
    • 2000
  • This paper presents an implementation of internet gateway system, named AX-2000 and call simulator. AX-2000 plays a important role in internet telephony technology and is composed of various board such as MPU, AVU. DVU, AMU. FXS, FXO, EM. Also AX-2000 supports G.729.a, G.723.1 for voice compression, G3 FAX Relay(T.38) and H.323. A capability of AX-2000 is 8 analog voice channel or 30 digital voice channel. For functional verification of AX-2000 voice interface, call simulator is designed. The call simulator makes actual call path between SUT(system under test) and reference AX-2000 system, then through call path examines functions of voice interface.

  • PDF

A Study on LAN Applications in Nuclear Safety System

  • Kim, Sung;Lee, Young-Ryul;Koo, Jun-Mo;Han, Jae-Bok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.166-172
    • /
    • 1995
  • It is a general tendency to digitalize the conventional relay based I&C systems in nuclear power plant. But, the digitalization of nuclear safety systems has many a difficulty to surmount. The typical on thing of many difficulties is the data communication problem between local controllers and systems. The network architecture built with LAN(Local Area Network) in digital systems of the other industries are general. But in case of nuclear safety systems many considerations in point of safety and license are required to implement it in the field. In this paper, some considerations for applying LAN in nuclear safety systems were reviewed.

  • PDF

VERIFICATION OF PLC PROGRAMS WRITTEN IN FBD WITH VIS

  • Yoo, Jun-Beom;Cha, Sung-Deok;Jee, Eun-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.79-90
    • /
    • 2009
  • Verification of programmable logic controller (PLC) programs written in IEC 61131-3 function block diagram (FBD) is essential in the transition from the use of traditional relay-based analog systems to PLC-based digital systems. This paper describes effective use of the well-known verification tool VIS for automatic verification of behavioral equivalences between successive FBD revisions. We formally defined FBD semantics as a state-transition system, developed semantic-preserving translation rules from FBD to Verilog programs, implemented a software tool to support the process, and conducted a case study on a subset of FBDs for APR-1400 reactor protection system design.

170kV GIS용 Rogowski coil형 CT개발 (Development of Rogowski-Coil Type CT for Application in 170kV GIS)

  • 정영환;김정배;송원표;김덕수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF