• 제목/요약/키워드: digital relay

검색결과 272건 처리시간 0.023초

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

디지털 무선중계 장치의 아날로그 기울기 등화기 구현 및 시스템 성능에 대한 연구 (A Study of Implementation of Analog Slope Equalizer and Its System Performance for Digital Radio Relay System)

  • 서경환
    • 한국전자파학회논문지
    • /
    • 제15권11호
    • /
    • pp.1034-1042
    • /
    • 2004
  • 본 논문에서는 64-QAM 디지털 무선중계 장치에 적용할 목적으로 주파수 선택적 페이딩 책 중의 하나인 아날로그 기울기 등화기의 이론적 모델, 구현 및 성능을 제시하였다. 또한 주파수 선택적 페이딩에 대해 기저대역 의 채널 모델링을 통해 I 및 Q 채 널의 상호간섭을 분석 하였고, 이 를 근거로 IF 대역에서 아날로그 기울기 등화기 구현을 위한 방법을 유도하였다. 페이딩을 받은 채널에 대해 기울기 등화기의 적용 유무에 따라 시간 및 주파수 영역에서 각각 신호의 영향을 살펴보았다. 그리고 무선중계 장치의 성능을 나타내는 시그너쳐(signature)를 통해 비트 오율 $10^{-3}$ 기준으로 신호 대역폭의 가장자리에서 약 6.2 dB 개선됨을 보였다.

초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구 (A basic study on protective relay testing using RTDS in power system applying SFCL)

  • 이승렬;윤재영;김재호;이병준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

동기식 디지틀 계위의 동일채널 무선 전송장치구현 및 성능분석 (Implementation of Co-Channel Radio Relay System and Its Performance Evaluation with Synchronous Digital Hierarchy)

  • 서경환
    • 전자공학회논문지D
    • /
    • 제35D권11호
    • /
    • pp.10-22
    • /
    • 1998
  • 본 논문에서는 주파수 효율향상 및 성능개선의 일환으로 최근에 개발된 동기식 무선 전송장치의 채널 모델링 및 성능분석에 대해 기술한다. 구현된 장치는 기존의 interleave 채널 배정에 비해 전송용량을 배가 시킬 수 있는 동일채널 방식을 적용하였으며, 성능 및 기능 측면에서 세계최초로 개발(1994년 5월)한 다용도 단일 ASIC 칩과 64-QAM 변.복조와 연동한 장치의 시험 결과를 제시하였다. 13-tap 복소 적응등화기 및 직교편파 간섭제거기의 적용은 기존의 9- 및 11-tap 에 비해 시그너쳐상에서 1.5 ∼ 2.0 dB 이상을 개선하였으며, 직교편파 간섭제거기의 이득은 24.5 dB 의 C/N 에서 약 22.5 dB 이상을 확보하였다. 또한 roll-off 인자를 외부에서 조절 가능한 디지틀 여파기의 적용으로 효율적인 점유 대역폭의 선택 및 관리가 가능토록 하였다. 이러한 고품질의 다용도 ASIC 칩 적용은 동일채널 무선 전송장치의 가용도 개선, 신뢰성 및 고부가가치 창출 등에 중요한 역할을 할 것으로 기대된다.

  • PDF

송전계통에서 EMTDC틀 이용한 고저항 지락사고특성 분석에 관한 연구 (A Study on the Characteristic Analysis of High Impedance Fault using EMTDC In Transmission System)

  • 박성훈;이종범;김영한;김일동;한경남;정창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.103-105
    • /
    • 1996
  • This paper describes real time dynamic tests on the digital distance relay using new digital test system including RTDS(Real Time Digital Simulator) in KEPRI. The RTDS is developed by the Manitoba HVDC Research Centre and consists of specialized hardware and software which allows transients simulation of electrical power systems in real time. From high impedance fault test, it is known that the characteristics of distance reach is influenced by load flow. A detailed discussion of relay test using the RTDS simulator, high impedance faults and test results are included in the paper.

  • PDF

객체지향 송전계통보호계전 그래픽 동작 시뮬레이터 (An Object Based Graphical Simulator for Power System Protection)

  • 민병운;이승재;최면송;김국진;김호표;이운희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.902-904
    • /
    • 1998
  • When the faults occur in power systems, the protective relay plays a roles of protecting power systems. It is important that the protective relay have high selectiveity and sencitivity performance in power system by correct setting the relays. This paper proposed a testing methods if the reliability of digital relay as simulating the response of relay at faults in the real power system operation environment.

  • PDF

디지털 무선 전송장치를 위한 기울기 등화기의 채널 모델링 및 디지털 구현에 관한 연구 (A Study on the Channel Modeling of Slope Equalizer and Its Digital Implementation for Digital Radio Relay System)

  • 서경환
    • 한국전자파학회논문지
    • /
    • 제12권5호
    • /
    • pp.777-786
    • /
    • 2001
  • 본 논문에서는 64-QAM 디지털 무선 전송장치에 적용할 목적으로 주파수 선택적 페이딩 대책 중의 하나인 디지털 기울기 등화기의 원리, 채널 모델링 및 디지털 구현방법을 분석하였다. 또한 복소 13-탭 시간영역의 적응 등화기 칩과 연동시의 성능분석을 수치계산으로 수행하였으며, 장치의 signature 특성을 통과대역 가장자리에서 약 4.5 dB 개선시킬 수 있음을 보였다. 그리고 디지털 기울기 등화기의 모델링에 대한 한계, 동작 자파수, 제어계수, 신호의 constellation, 장치의 성능에 대한 다양한 결과도 검토하였다. 끝으로 61 MHz 클럭까지 동작시험을 검증한 디지털 기울기 등화기의 칩에 대한 기능을 소개한다.

  • PDF

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.