• Title/Summary/Keyword: digital relay

Search Result 272, Processing Time 0.022 seconds

A Study on Programmable Logic-based Smart Peak Power Control System (프로그램 로직 기반의 스마트 최대 전력 관리 시스템에 관한 연구)

  • Lee, Woo-Cheol;Kwon, Sung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-99
    • /
    • 2014
  • The paper is related to smart maximum power system based on program logic. Especially, this system compares the total demand power with the target power by using the signal from the digital kilo watt meter. Based on the power information by the maximum power control equipment the consumed future power is anticipated. In addition, through consumed future power the controllable target power is set, and it applies on the maximum power control equipment. User or manager would control the load efficiently through the simple programming which could control load based on the control sequence and relay. To begin with the conventional maximum power control algorithm is surveyed, and the smart maximum power control system based on program logic is used, and the new algorithm from full load to proportion shut down is proposed by using PLC program. the validity of the proposed control scheme is investigated by both simulation results.

A Network Coding for Multi-Hop Ship-to-Ship Communications (다중-홉 선박간 통신을 위한 네트워크 부호화 기법)

  • Do, Thinh Phu;Shin, Dongryul;Lee, Seong Ro;Jeong, Min-A;Kim, Yun Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.7
    • /
    • pp.566-572
    • /
    • 2014
  • We propose a two-way multi-hop relaying scheme improving the throughput as well as enlarging the coverage for ship-to-ship communications in multi-ship marine networks. The proposed scheme reduces the time slots required for the data exchange by designing data transmission and network coding procedures in a sophisticated way based on two-phase digital network coding. Simulation results show that the proposed two-way multi-hop relaying scheme improves the throughput of the conventional one about 5/3 times.

Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method (DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘)

  • Lee, Dong-Gyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.

Advanced DC Offset Removal Filter of High-order Configuration (고차 구성의 개선된 직류 옵셋 제거 필터)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Fault currents are expressed as a combination of harmonic components and exponentially decaying DC offset components, during the occurrence of fault in power system. The DC offset components are included, when the voltage phase angle of fault inception is closer to $0^{\circ}$ or $180^{\circ}$. The digital protection relay should be detected quickly and accurately during the faults, despite of the distortions of relaying signal by these components. It is very important to implement the robust protection algorithm, that is not affected by DC offset and harmonic components, because most relaying algorithms extract the fundamental frequency component from distorted relaying signal. So, In order to high performance in relaying, advanced DC offset removal filter is required. In this paper, a new DC offset removal filter, which is no need to preset a time constant of power system and accurately estimate the DC offset components with one cycle of data, is proposed, and compared with the other filter. In order to verify performance of the filter, we used collecting the current signals after synchronous machine modeling by ATPDraw5.7p4 software. The results of simulation, the proposed DC offset removal filter do not need any prior information, the phase delay and gain error were not occurred.

Cooperative Transmission Scheme in OFDMA Uplink System (OFDMA 상향 시스템에서의 협동 전송 기법)

  • Yoon, Jae-Seon;Song, Hyoung-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5A
    • /
    • pp.475-483
    • /
    • 2007
  • Recently, consumers demand high-quality wireless multimedia services via terrestrial and satellite network. And the interest for new services to sustain its successful commercial deployment grows tremendously. So, the MIMO schemes, such as STCs, MRC, has been used for realizing high reliability. However, MIMO schemes has some limitations. MIMO scheme needs more size, cost, and hardware complexity to employ additional antennas. Moreover, sufficient spaces between antennas are required to guarantee the independence of each channel and the devices which use multiple antennas should be enlarged. A cooperative transmission technique which is detect and forward type applying virtual MIMO with STBC matrix in DVB-RCT(Digital Video Broadcasting with Return Channel via Terrestrial) system based on OFDMA is also proposed.

원격지의 시각동기를 위한 일반적인 방법에 대한 고찰

  • Kim, Bang-Yeop;Lee, Sang-Cherl
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.98-107
    • /
    • 2003
  • In this study, a survey of time synchronization methods between the remote places. Generally, there are many kinds of time synchronization methods for distant places and they can be grouped three categories according to the type of time transfer methods. The three methods are ground based network, GPS/NAVSTAR and geostationary satellite. Especially, the relay base stations for wireless digital communication are operated based on the timing signal service of the GPS/NAVSTAR satellite network. And as the back-up of the timing signal service of the GPS/NAVSTAR, the geostationary satellite based time synchronization method have researched. In this short paper, the brief explanations about each category were presented.

  • PDF

An Adaptive Key Redistribution Method for Filtering-based Wireless Sensor Networks

  • Kim, Jin Myoung;Lee, Hae Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2518-2533
    • /
    • 2020
  • In wireless sensor networks, adversaries may physically capture sensor nodes on the fields, and use them to launch false positive attacks (FPAs). FPAs could be conducted by injecting forged or old sensing reports, which would represent non-existent events on the fields, with the goal of disorientating the base stations and/or reducing the limited energy resources of sensor nodes on the fields. Researchers have proposed various mitigation methods against FPAs, including the statistical en-route filtering scheme (SEF). Most of these methods are based on key pre-distribution schemes and can efficiently filter injected false reports out at relay nodes through the verification of in-transit reports using the pre-distributed keys. However, their filtering power may decrease as time goes by since adversaries would attempt to capture additional nodes as many as possible. In this paper, we propose an adaptive key distribution method that could maintain the security power of SEF in WSNs under such circumstances. The proposed method makes, if necessary, BS update or re-distribute keys, which are used to endorse and verify reports, with the consideration of the filtering power and energy efficiency. Our experimental results show that the proposed method is more effective, compared to SEF, against FPAs in terms of security level and energy saving.

Radio Coverage Prediction of DMO Terminal in TETRA TRS (TETRA TRS에서 DMO 단말기의 전파도달범위 예측)

  • Lee, Soon-Hwa;Kim, Chang-Bock
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.51-56
    • /
    • 2014
  • TETRA(TErrestrial Trunked RAdio) provide specialized disaster radio communication services as a standard European for digital TRS(Trunked Radio System). Especially, DMO(Direct Mode Operation) feature is used effectively in the radio shadow areas which base station does not propagate radio signal because it can communicate directly with terminal to terminal without base station's relay function. However, to effectively used DMO feature, radio coverage prediction information should be provided to users. Therefore in this paper, we were calculated link budget of TETRA DMO terminals which were distributing and operating in the country and then predicted reaching distance about radio propagation to be applied with path loss model.

A Study on the Out-of-Step Detection Algorithm using Frequency Deviation of the Voltage (전압의 주파수 편의를 이용한 동기탈조 검출 알고리즘에 관한 연구)

  • 소광훈;허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.175-181
    • /
    • 2004
  • The protection against transient instability and consequent out-of-step condition is a major concern for the utility industry. Unstable system may cause serious damage to system elements such as generators and transmission lines. Therefore, out-of-step detection is essential to operate a system safely. The detection of out-of-step is generally based upon the rate of movement of the apparent impedance. However such relay monitors only the apparent impedance which may not be sufficient to correctly detect all forms of out-of-step and cannot cope with out-of-step for a more complex type of instability such as very fast power swing. This paper presents the out-of-step detection algorithm using voltage frequency deviation. The digital filters based on discrete Fourier transforms (DFT) to calculate the frequency of a sinusoid voltage are used, and the generator angle is estimated using the deviation of the calculated frequency component of the voltage. The proposed out-of-step algorithm is based on the assessment of a transient stability using equal area criterion. The proposed out-of-step algorithm is verified and tested by using EMTP MODELS.

Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay (디지털보호계전기를 이용한 기중차단기 제어 및 모니터링)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF