• Title/Summary/Keyword: digital reference

Search Result 1,283, Processing Time 0.026 seconds

Adaptive Digital Predictive Peak Current Control Algorithm for Buck Converters

  • Zhang, Yu;Zhang, Yiming;Wang, Xuhong;Zhu, Wenhao
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.613-624
    • /
    • 2019
  • Digital current control techniques are an attractive option for DC-DC converters. In this paper, a digital predictive peak current control algorithm is presented for buck converters that allows the inductor current to track the reference current in two switching cycles. This control algorithm predicts the inductor current in a future period by sampling the input voltage, output voltage and inductor current of the current period, which overcomes the problem of hardware periodic delay. Under the premise of ensuring the stability of the system, the response speed is greatly improved. A real-time parameter identification method is also proposed to obtain the precision coefficient of the control algorithm when the inductance is changed. The combination of the two algorithms achieves adaptive tracking of the peak inductor current. The performance of the proposed algorithms is verified using simulations and experimental results. In addition, its performance is compared with that of a conventional proportional-integral (PI) algorithm.

Enhancing the Cybersecurity Checklist for Mobile Applications in DTx based on MITRE ATT&CK for Ensuring Privacy

  • Gee-hee Yun;Kyoung-jin Kim
    • Journal of Internet Computing and Services
    • /
    • v.24 no.4
    • /
    • pp.15-24
    • /
    • 2023
  • Digital therapeutics (DTx) are utilized to replace or supplement drug therapy to treat patients. DTx are developed as a mobile application for portability and convenience. The government requires security verification to be performed on digital medical devices that manage sensitive information during the transmission and storage of patient data. Although safety verification is included in the approval process for DTx, the cybersecurity checklist used as a reference does not reflect the characteristics of mobile applications. This poses the risk of potentially overlooking vulnerabilities during security verification. This study aims to address this issue by comparing and analyzing existing items based on the mobile tactics, techniques, and procedures of MITRE ATT&CK, which manages globally known and occurring vulnerabilities through regular updates. We identify 16 items that require improvement and expand the checklist to 29 items to propose improvement measures. The findings of this study may contribute to the safe development and advancement of DTx for managing sensitive patient information.

MANAGEMENT OF DIGITAL DESIGN DATA IN BUILDING DESIGN AND CONSTRUCTION UNITS

  • Linas Gabrielaitis ;Romualdas Bausys
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.725-730
    • /
    • 2005
  • The problem of managing digital design data including drawings, specifications and other technical data in building design and construction units is a real challenge, especially when there is a need to structure the design information across building design companies. The main difficulty in this information management is the shortage of unified rules (or standards) on how the digital design data should be gathered, archived, and preserved in the most efficient way for building design and construction units. The most important issue, which addressed in this work, is the standardized reference of all design data definitions.

  • PDF

A Range-Scaled 13b 100 MS/s 0.13 um CMOS SHA-Free ADC Based on a Single Reference

  • Hwang, Dong-Hyun;Song, Jung-Eun;Nam, Sang-Pil;Kim, Hyo-Jin;An, Tai-Ji;Kim, Kwang-Soo;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.2
    • /
    • pp.98-107
    • /
    • 2013
  • This work describes a 13b 100 MS/s 0.13 um CMOS four-stage pipeline ADC for 3G communication systems. The proposed SHA-free ADC employs a range-scaling technique based on switched-capacitor circuits to properly handle a wide input range of $2V_{P-P}$ using a single on-chip reference of $1V_{P-P}$. The proposed range scaling makes the reference buffers keep a sufficient voltage headroom and doubles the offset tolerance of a latched comparator in the flash ADC1 with a doubled input range. A two-step reference selection technique in the back-end 5b flash ADC reduces both power dissipation and chip area by 50%. The prototype ADC in a 0.13 um CMOS demonstrates the measured differential and integral nonlinearities within 0.57 LSB and 0.99 LSB, respectively. The ADC shows a maximum signal-to-noise-and-distortion ratio of 64.6 dB and a maximum spurious-free dynamic range of 74.0 dB at 100 MS/s, respectively. The ADC with an active die area of 1.2 $mm^2$ consumes 145.6 mW including high-speed reference buffers and 91 mW excluding buffers at 100 MS/s and a 1.3 V supply voltage.

A Novel Parameter-independent Fictive-axis Approach for the Voltage Oriented Control of Single-phase Inverters

  • Ramirez, Fernando Arturo;Arjona, Marco A.;Hernandez, Concepcion
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.533-541
    • /
    • 2017
  • This paper presents a novel Parameter-Independent Fictive-Axis (PIFA) approach for the Voltage-Oriented Control (VOC) algorithm used in grid-tied single-phase inverters. VOC is based on the transformation of the single-phase grid current into the synchronous reference frame. As a result, an orthogonal current signal is needed. Traditionally, this signal has been obtained from fixed time delays, digital filters or a Hilbert transformation. Nevertheless, these solutions present stability and transient drawbacks. Recently, the Fictive Axis Emulation (FAE) VOC has emerged as an alternative for the generation of the quadrature current signal. FAE requires detailed information of the grid current filter along with its transfer function for signal creation. When the transfer function is not accurate, the direct and quadrature current components present steady-state oscillations as the fictive two-phase system becomes unbalanced. Moreover, the digital implementation of the transfer function imposes an additional computing burden on the VOC. The PIFA VOC presented in this paper, takes advantage of the reference current to create the required orthogonal current, which effectively eliminates the need for the filter transfer function. Moreover, the fictive signal amplitude and phase do not change with a frequency drift, which results in an increased reliability. This yields a fast, linear and stable system that can be installed without fine tuning. To demonstrate the good performance of the PIFA VOC, simulation and experimental results are presented.

Fluoroscopy examinations for the management of patient dose study on the establishment of diagnostic reference level (UGI, Esophagography standards) (투시 조영 검사 시 환자 선량 관리를 위한 진단참고선량 구축에 관한 연구 (UGI, Esophagography 기준))

  • Hong, Sun-Suk;Park, Eun-Seong;Cho, Joon-Yeong;Seong, Min-Suk;Yang, Han-Joon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • This round of tests in patients with UGI and Esophagography data collected by national and international reference levels based on the original set of guidelines and fluoroscopy, through the provision of medical radiation exposure reduction and further optimization of Defense to realize that is intended. 359 names in our hospital underwent Esophagography 302 patients who underwent UGI average fluoroscopy time and number of images to calculate the average 21 cm Acryl phantom dose for 10 seconds and 20 seconds, average area dose and the area dose of 1 spot image, 5 spot consecutive images by measuring the patient dose and third quartile of the mean area dose was set seonryangin reference dose. Esophagography average patient dose was set to 30.05 $Gy{\cdot}cm^2$, DRL was set at a 25.37 $Gy{\cdot}cm^2$. Average dose of UGI patients were selected as 45.33 $Gy{\cdot}cm^2$, DRL was set at a 34 $Gy{\cdot}cm^2$. UGI patients with established average dose recommended in the 2008 national recommendation from the UGI examination with a dose of less than 49.7 $Gy{\cdot}cm^2$ seonryangin is evaluated. This Note examines the dose of self-aware through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

Design of Robust Double Digital Controller to Improve Performance for UPS Inverter (UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계)

  • 박지호;노태균;김춘삼;안인모;우정인
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.116-127
    • /
    • 2003
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an Internal model controller The Internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Used Textbook Trading Platform to Recommend University Textbooks (대학 교재 추천 기능을 지원하는 중고 전공서적 거래 플랫폼)

  • Kim, Bit-Chan;Lee, Sang-Yong
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.329-334
    • /
    • 2018
  • According to the textbook utilization survey, university students buy 6.4 books and spend 94,000 won per semester. However, nearly half of books are left unused. Therefore many students buy used textbooks instead of buying new books at a fixed price. The existing used textbook trading platforms support basic functions, but don't support textbook recommendation function and reference book recommendation function. In this paper, we developed a used textbook trading platform BookCue that provides textbook recommendation function, reference book recommendation function, and consignment trading function reflecting the regional characteristics. It is expected that will contribute to reduce university students' burden that buying textbook by forming textbooks trading environment and preserve environment. In the near future our platform will need to expand to a platform that deals with a variety of goods, as well as used textbooks in the region.

A Mixed-Signal IC for Magnetic Stripe Storage System (자기 띠 저장 시스템을 위한 혼성 신호 칩)

  • Lim, Shin-Il;Choi, Jong-Chan
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.34-41
    • /
    • 1998
  • An integrated circuit for magnetic stripe storage system is implemented. All the analog and digital circuits are integrated in one chip. The analog block contains preamplifier, peak detecter, comparator and reference generater. And digital block includes reference window signal generater, up/down counter for F/2F signal measurement, bit-error detection logic, and control logic. Both the encoding and decoding functions for F/2F signal processing are provided. An AGC(automatic gain control) circuit which was included in conventional circuits is eliminated due to optimized circuit design. Misreading prevention circuits are also proposed by fixing up new reference bit when broken bits are detected. The prototype chip is implemented using $0.8{\mu}m$ N-well CMOS technology and operates from 3.3 V to 7.5 V of supply voltage. It occupies a die area of $3.04mm^2(1.6mm{\times}1.9mm)$ and dissipates 8 mW with a 5 V supply voltage.

  • PDF

A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF