• Title/Summary/Keyword: digital reference

Search Result 1,283, Processing Time 0.027 seconds

Analysis and Improvement of Interior Orientation Accuracy of KOMPSAT-2 PANchromatic Bands (KOMPSAT-2 영상 PAN밴드의 내부표정 정확도 분석 및 개선방안 연구)

  • Kim, Tae-Jung;Jeong, Jae-Hoon;Kim, Deok-In
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.4
    • /
    • pp.439-449
    • /
    • 2010
  • This paper reports experiments and analysis work done to find out the cause of Y parallex for stereo pairs of KOMPSAT-2 images and means to improve the Y parallex problem. We could conclude that the Y parallex problem was caused by resampling errors of KOMPSAT-2 PANchromatic bands, induced by the process of warping PANchromatic band with reference to multispectral bands. We could also conclude that a rigorous warping process could improve resampling of KOMPSAT-2 PANchromatic band and remove the Y parallex problem significantly. We also confirmed that a rigorous warping process could also remove blocky brightness patterns present on KOMPSAT-2 PANchromatic band. Therefore, by implementing more rigorous warping process within KOMPSAT-2 scene generation procedures, KOMPSAT-2 geometric and radiometric quality will be improved.

A fully deep learning model for the automatic identification of cephalometric landmarks

  • Kim, Young Hyun;Lee, Chena;Ha, Eun-Gyu;Choi, Yoon Jeong;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.299-306
    • /
    • 2021
  • Purpose: This study aimed to propose a fully automatic landmark identification model based on a deep learning algorithm using real clinical data and to verify its accuracy considering inter-examiner variability. Materials and Methods: In total, 950 lateral cephalometric images from Yonsei Dental Hospital were used. Two calibrated examiners manually identified the 13 most important landmarks to set as references. The proposed deep learning model has a 2-step structure-a region of interest machine and a detection machine-each consisting of 8 convolution layers, 5 pooling layers, and 2 fully connected layers. The distance errors of detection between 2 examiners were used as a clinically acceptable range for performance evaluation. Results: The 13 landmarks were automatically detected using the proposed model. Inter-examiner agreement for all landmarks indicated excellent reliability based on the 95% confidence interval. The average clinically acceptable range for all 13 landmarks was 1.24 mm. The mean radial error between the reference values assigned by 1 expert and the proposed model was 1.84 mm, exhibiting a successful detection rate of 36.1%. The A-point, the incisal tip of the maxillary and mandibular incisors, and ANS showed lower mean radial error than the calibrated expert variability. Conclusion: This experiment demonstrated that the proposed deep learning model can perform fully automatic identification of cephalometric landmarks and achieve better results than examiners for some landmarks. It is meaningful to consider between-examiner variability for clinical applicability when evaluating the performance of deep learning methods in cephalometric landmark identification.

A study on competencies of designer in forth industrial revolution (4차 산업혁명 시대 디자이너의 역량에 관한 고찰)

  • Jo, Gyu-Eun;Kim, Seung-In
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.167-173
    • /
    • 2019
  • The purpose of this study is to propose the direction of competence of future designers required in the fourth industrial revolution. Designers have played an intermediary role in connecting technology and human beings. Therefore, in the fourth industrial revolution the capacity required to perform the intermediate role as a designer has also changed. The paradigm of design which changed step by step through the literature survey was studied. In addition, priorities were confirmed by comparing past and future designer competencies through prior research on designer competencies. As a result, we confirmed that the planning competence to solve complex problems and the competence of design management to realize them. Based on this research, we hope to be able to recognize the direction of competence as a designer in the fourth industrial revolution and to be a reference material for the follow - up study.

A Study on Modified Adaptive Weighted Filter in Mixed Noise Environments (복합잡음 환경에서 변형된 적응 가중치 필터에 관한 연구)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.798-801
    • /
    • 2014
  • Nowadays, the demand for multimedia services has grown with the rapid evolution in the digital era. But due to external causes in the process of processing, transmitting and storing image data, the images are damaged. One of the major causes of such damage is known to be noise. Some of the most commonly used methods for removing noise are CWMF(center weighted median filter), A-TMF(alpha-trimmed mean filter) and AWMF(adaptive weighted median filter). However, these filters all leave a bit to be desired in removing noise in a complex noise environment. Therefore this paper suggest an image restoration filter algorithm that first judges the noise and sets a adjustment weight based on the median value and distance of the mask to remove the complex noise. For an objective analysis, the results were compared against existing methods and the PSNR(peak signal to noise ratio) was used as a reference.

  • PDF

An ASIC Design for Photon Pulse Counting Particle Detection (광계수방식 물리입자 검출용 ASIC 설계)

  • Jung, Jun-Mo;Soh, Myung-Jin;Kim, Hyo-Sook;Han, AReum;Soh, Seul-Yi
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this paper is to explore an ASIC design for estimating sizes and concentrations of airborne micro-particles by the means of integrating, amplifying and digitizing electric charge signals generated by photo-sensors as it receives scattered photons by the presence of micro-particles, consisting of a pre-amplifier that detects and amplifies voltage or current signal from photo-sensor that generates charges (hole-electron pairs) when exposed to visible rays, infrared rays, ultraviolet rays, etc. according to the intensity of rays; a shaper for shaping the amplified signal to a semi-gaussian waveform; two discriminators and binary counters for outputting digital signals by comparing the magnitude of the shaped signal with an arbitrary reference voltages. The ASIC with the proposed architecture and functional blocks in this study was designed with a 0.18um standard CMOS technology from Global Foundries and the operation and performances of the ASIC has been verified by the silicons fabricated by using the process.

A Study of System Design for Management the Confidential Records (비밀기록을 관리하기 위한 시스템 설계 연구)

  • Hong, Deok-Yong
    • The Korean Journal of Archival Studies
    • /
    • no.52
    • /
    • pp.277-313
    • /
    • 2017
  • With the enactment of regulations on confidential records management, the management of confidential records has become more important than ever. However, there remains no management method in the field of records management that takes the feature and values of confidential records into consideration. For this, this study processed electronically confidential records managed in a non-electronic environment. In addition, we developed a system that will allow public institutions to manage confidential records independently, that will prevent loss of information because of loss of or damage to the confidential records, and that can be used conveniently in the digital security environment of authorized users to establish a foundation for commercial management. In this study, we analyzed the system configuration requirements according to the international standard for the records management of a confidential records management system and system-related issues such as system design based on the analyzed requirements, system security and encryption, and metadata, the overall process of establishing and outputting secret management records and standard management.

Image Restoration Algorithm using Weighted Switching Filter for Remove Random-Valued Impulse Noise (랜덤 임펄스 잡음을 제거하기 위한 가중치 스위칭 필터를 이용한 영상 복원 알고리즘)

  • Cheon, Bong-Won;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2020
  • In the modern society, the use of digital equipment is increasing along with the 4th industrial revolution, and the importance of image and signal processing is increasing. At the same time, research on noise reduction is being actively conducted. In this paper, we propose a switching filter algorithm for random-valued impulse noise cancellation. The proposed algorithm obtains the threshold value by determining the noise level present in the image, and threshold value is compared with the difference between the input pixel value and the reference value, and is used in the weight switching process of the filter. The final output of the filter is estimated by applying a pixel weight and a modified weight median filter according to the switching, and obtains a final output by comparing the estimated value with the input pixel value. To evaluate the performance of the proposed algorithm, we compared it with the existing methods using simulation and PSNR.

Age Estimation with Panoramic Radiomorphometric Parameters Using Generalized Linear Models

  • Lee, Yeon-Hee;An, Jung-Sub
    • Journal of Oral Medicine and Pain
    • /
    • v.46 no.2
    • /
    • pp.21-32
    • /
    • 2021
  • Purpose: The purpose of the present study was to investigate the correlation between age and 34 radiomorphometric parameters on panoramic radiographs, and to provide generalized linear models (GLMs) as a non-invasive, inexpensive, and accurate method to the forensic judgement of living individual's age. Methods: The study included 417 digital panoramic radiographs of Korean individuals (178 males and 239 females, mean age: 32.57±17.81 years). Considering the skeletal differences between the sexes, GLMs were obtained separately according to sex, as well as across the total sample. For statistical analysis and to predict the accuracy of the new GLMs, root mean squared error (RMSE) and adjusted R-squared (R2) were calculated. Results: The adjusted R2-values of the developed GLMs in the total sample, and male and female groups were 0.623, 0.637, and 0.660, respectively (p<0.001), while the allowable RMSE values were 8.80, 8.42, and 8.53 years, respectively. In the GLM of the total sample, the most influential predictor of greater age was decreased pulp area in the #36 first molar (beta=-26.52; p<0.01), followed by the presence of periodontitis (beta=10.24; p<0.01). In males, the most influential factor was the presence of periodontitis (beta=9.20; p<0.05), followed by the number of full veneer crowns (beta=2.19; p<0.001). In females, the most influential predictor was the presence of periodontitis (beta=18.10; p<0.001), followed by the tooth area of the #16 first molar (beta=-11.57; p<0.001). Conclusions: We established acceptable GLM for each sex and found out the predictors necessary to age estimation which can be easily found in panoramic radiographs. Our study provides reference that parameters such as the area of tooth and pulp, the number of teeth treated, and the presence of periodontitis should be considered in estimating age.

An Efficient Method for Aneurysm Volume Quantification Applicable in Any Shape and Modalities

  • Chung, Jaewoo;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.514-523
    • /
    • 2021
  • Objective : Aneurysm volume quantification (AVQ) using the equation of ellipsoid volume is widely used although it is inaccurate. Furthermore, AVQ with 3-dimensional (3D) rendered data has limitations in general use. A novel universal method for AVQ is introduced for any diagnostic modality and application to any shape of aneurysms. Methods : Relevant AVQ studies published from January 1997 to June 2019 were identified to determine common methods of AVQ. The basic idea is to eliminate the normal artery volume from 3D model with the aneurysm. After Digital Imaging and Communications in Medicine (DICOM) data is converted and exported to stereolithography (STL) file format, the 3D STL model is modified to remove the aneurysm and the volume difference between the 3D model with/without the aneurysm is defined as the aneurysm volume. Fifty randomly selected aneurysms from DICOM database were used to validate the different AVQ methods. Results : We reviewed and categorized AVQ methods in 121 studies. Approximately 60% used the ellipsoid method, while 24% used the 3D model. For 50 randomly selected aneurysms, volumes were measured using 3D Slicer, RadiAnt, and ellipsoid method. Using 3D Slicer as the reference, the ratios of mean difference to mean volume obtained by RadiAnt and ellipsoid method were -1.21±7.46% and 4.04±30.54%, respectively. The deviations between RadiAnt and 3D Slicer were small despite of aneurysm shapes, but those of ellipsoid method and 3D Slicer were large. Conclusion : In spite of inaccuracy, ellipsoid method is still mostly used. We propose a novel universal method for AVQ that is valid, low cost, and easy to use.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.