• Title/Summary/Keyword: digital impression

Search Result 164, Processing Time 0.025 seconds

An Analysis and Comparison on Creative of Local Government's TV Commercial (지방자치단체 TV광고의 크리에이티브 비교분석)

  • Paik, Jae-Hun
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.121-132
    • /
    • 2007
  • A change of social environment based on digital information technology has decreased the disparity of regional cultures by exchanging & consuming contemporary information & culture freely. After 1995, when local autonomous entity system was established, the local autonomous bodies competed with one another in developing the regional society with its' own resources, human powers & cultures, independently of the central government. In the competitive system, a local government is getting itself distinguished from each other in the cultural & regional properties, and brands the region with its unique events, public relations(PR) & development strategies. The environment for advertisement has changed rapidly under the spontaneous system of regional brand and competition, which means the changes of creative standard in the field of advertisement. An in-depth advertising creativity with induced impression & trust is one of the most important aspects of the advertisement to become persuasive to the public effectively. This demand has had public advertisements changed rapidly and the change of regional system's advertisements has started already. This study focuses on analyzing the status of Local Government's commercials on TV, and presenting an effective method for improving it.

  • PDF

Human Skeletal X-ray Projection Images Applied Fashion Design (인체 골격의 X-ray 투사 이미지를 활용한 패션디자인)

  • Park, Jungin;Lee, Younhee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.3
    • /
    • pp.13-27
    • /
    • 2015
  • The purpose of this study is to understand the general process from textile design till fashion design and to understand the relation between the body structure by using the x-ray technique. The research method was to see background of the anatomic feature and human skeletal X-ray projection through historical aspect of publications, the Internet, and paper. In terms of production, in order to present a design that takes into account the unique silhouette of the human body without distorting the shape of the human skeleton, X-ray images that were reconstituted using a computer graphic tool (Photoshop CS) were reproduced into the fabric as intense images through the digital Textile Printing technique that is capable of expressing fine and delicate details, and applied into the design. An original design was developed that emphasized the impression of the human body being projected and the shape of the human skeleton realistically expressed in terms of silhouette and detail. The results are as follows: First, Body has a anatomic formative characteristic and its formativeness becomes as a great motive for the artistic expression and thereby it becomes more unique and available for new design expression. Second, Using the 'body frame' as the motive of the research, there's mainly tried to make an unique expression. Third, according to reconstructing human skeletal X-ray projection by using Adobe Photoshop CS2, it can be expressed strong and unique design. Forth, DTP which is being used as an essential technique, expresses the body frame realistically and being used the special type of functional product and silk. Likewise by discovering the diverse formativeness of our body frame and reflecting the sense of humanity into the pieces there's been able to make and develop an unique fashion design. I sincerely hope there is a hug progress in this research in this area.

  • PDF

Accuracy Verification of 3D printing model by Using Domestic Oral Scanner(eZIS) (국내산 구강스캐너(eZIS)를 사용한 3D프린트 모형의 정확도 검증 실험)

  • Byun, Tae-hee;Nam, Min-kyung;Kim, Jung-ho;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.40 no.3
    • /
    • pp.115-123
    • /
    • 2018
  • Purpose: The purpose of this study was establishing process of manufacturing dental prosthesis by using eZIS system(DDS Inc.,Korea). Methods: To evaluate accuracy verification, the test was practiced two ways. First, Comparison of 3D printing models and stone models was practiced by using 3D superimposing software. #36 prepared master model was scanned by eZIS system and three 'Veltz3D' 3D printing models and three 'Bio3D' 3D printing models were manufactured. three stone models were manufactured by conventional impression technique. Second, Fitness test was practiced. the 3D printing models and the stone models was compared by manufacturing same resin crown. #36 prepared master model was scanned 9 times and manufactured (milled) 9 resin crowns by eZIS system. These crowns were cemented three 'Veltz3D' 3D printing models, three 'Bio3D' 3D printing models and three stone models. These crowns were sliced mesiodistal axis and gaps were measured by digital microscope. Results: The average accuracy of Bio3D models were 65.75%. Veltz3D(Hebsiba) models were 60.11% Stone models were 41.00%. Conclusion : This study results showed 3D printing model is similar with stone model. So it was under clinical allow, didn't affect final dental prothesis. There were no significant differences in the appearance of the three types of milling crowns.

Comparative evaluation of marginal and internal fit of three-unit Co-Cr frameworks fabricated by metal milling and direct metal laser sintering methods (금속 밀링과 직접 금속 레이저 소결 방식으로 제작한 3본 코발트-크롬 구조물의 변연 및 내부 적합도 비교 평가)

  • Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.81-89
    • /
    • 2020
  • Purpose: This in vitro study was conducted to evaluate the marginal and internal fit of three-unit Co-Cr frameworks fabricated by computer-aided metal milling and direct metal laser sintering(DMLS) systems in comparison to conventional casting method. Methods: Three-unit Co-Cr frameworks were fabricated by conventional wax up with casting(CWC), computer-aided metal milling(MM) and direct metal laser sintering(DMLS)(n=10 each). The marginal and internal fit of specimens were examined using a light-body silicone impression material. The thickness of light-body silicone was measured at eight reference points each, divided in the mesio distal and bucco lingual directions. All measurements were conducted by a stereomicroscope. Digital photos were taken at 150× magnification and then analyzed using a measurement software. The Kruskal-Wallis test and Bonferroni correction were used for analyzing the results. Results: The mean(SD) is ㎛ for fabrication methods, the mean marginal fit were recorded respectively, DMLS 39(27), followed by CWC 63(38), MM 220(128). and the mean internal fit CWC 95(47), DMLS 116(49), MM 210(152). In addition, the largest gap was found in the occlusal surface area among the internal measurement areas of all groups. Conclusion: As a result, the direct metal laser sintering method showed better marginal and internal fit than the metal milling method. The marginal and internal fit were statistically different according to the three fabrication methods(p<0.001). Except the MM group, the marginal fit of the CWC and DMLS groups was below the clinical standard of 120 ㎛. Based on the results of this study, it can be applied to clinical use in the future.

An image used by cross concept of two images - Gap of image space2 - (두가지 영상의 교차개념을 도입한 영상설치작품 - 상 공간의 틈새2 -)

  • Cho Ok-Hue;Lee Jun-Eui;Kim Hyung-Gi
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.205-208
    • /
    • 2006
  • This work is a interactive digital art work which used the multiplex of jitter. It is an work which used a cross concept of two images. This work shows two kinds of images. One is on the wall through the gap of fluorescent lamp screen, and the other is on the fluorescent lamp screen. Two images are intercepted and comes out to the length as the multiplex of the jitter. The appearance of the spectator be recognized on the fluorescent lamp screen or on the wall, by two branch image which comes out intersecting of a length with multiplex function of the jitter. Two branch features of the image which it produces and the spectator which is input at real-time is equally divided, or in impression of juxtaposition goes in the spectator. It expresses the duplicity of the human being, with physical existence space divides the time space which we feel and there is a governing grammar which is different with each other and to express the thing it becomes. It used the image of the screen which it produces with the fluorescent lamp and cross concept.

  • PDF

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

An Investigation on Non-Relevance Criteria for Image in Failed Image Search (이미지 검색 실패에 나타난 비적합성 평가요소 규명에 관한 연구)

  • Chung, EunKyung
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.50 no.1
    • /
    • pp.417-435
    • /
    • 2016
  • Relevance judgment is important in terms of improving the effectiveness of information retrieval systems, and it has been dominant for users to search and use images utilizing internet and digital technologies. However, in the field of image retrieval, there have been only a few studies in terms of identifying relevance criteria. The purpose of this study aims to identify and characterize the non-relevance criteria from the failed image searches. In order to achieve the purpose of this study, a total of 135 participants were recruited and a total of 1,452 criteria items were collected for this study. Analyses and identification on the data set found thirteen criteria such as 'topicality', 'visual content', 'accuracy', 'visual feature', 'completeness', 'appeal to user', 'focal point', 'bibliographic information', 'impression', 'posture', 'face feature', 'novelty', and 'time frame'. Among these criteria, 'visual content' and 'focal point' were introduced in this current study, while 'action' criterion identified in previous studies was not shown in this current study. When image needs and image uses are analyzed with these criteria, there are distinctive differences depending on different image needs and uses.

Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS) (Ceramill full denture system을 이용한 무치악 환자의 양악 총의치 제작)

  • Lee, Younghoo;Kwon, Kung-Rock;Pae, Ahran;Noh, Kwantae;Paek, Janghyun;Hong, Seoung-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.232-237
    • /
    • 2019
  • CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced for the fabrication of complete dentures in 1994. This paper describes a technique that combines conventional and CAD/CAM technology for the fabrication of complete dentures: the master casts from a conventional impression techniques were scanned first, and the wax denture was fabricated using Amann Girrbach's Ceramill full denture system (fds). The purpose of this paper is to introduce the case in which making an esthetically and functionally satisfied denture in shorter time is possible with CAD/CAM technology.

Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision

  • Kwon, Miran;Cho, Youngmok;Kim, Dong-Wook;Kim, MyungSu;Kim, Yoon-Ji;Chang, Minho
    • The korean journal of orthodontics
    • /
    • v.51 no.2
    • /
    • pp.95-104
    • /
    • 2021
  • Objective: To evaluate the trueness and precision of full-arch scans acquired using five intraoral scanners and investigate the factors associated with the dimensional accuracy of the intraoral scan data. Methods: Nine adult participants (mean age, 34.3 ± 8.3 years) were recruited. Four zirconium spheres (Ø 6 mm) were bonded to the canines and the molars. Following acquisition of reference scans using an industrial-grade scanner, five intraoral scanners, namely i500, CS3600, Trios 3, iTero, and CEREC Omnicam, were used to scan the arches. Linear distances between the four reference spheres were automatically calculated, and linear mixed model analysis was performed to compare the trueness and precision of the intraoral scan data among the different scanners. Results: The absolute mean trueness and precision values for all intraoral scanners were 76.6 ± 79.3 and 56.6 ± 52.4 ㎛, respectively. The type of scanner and the measured linear distances had significant effects on the accuracy of the intraoral scan data. With regard to trueness, errors in the intermolar dimension and the distance from the canine to the contralateral molar were greater with Omnicam than with the other scanners. With regard to precision, the error in the linear distance from the canine to the molar in the same quadrant was greater with Omnicam and CS3600 than with the other scanners. Conclusions: The dimensional accuracy of intraoral scan data may differ significantly according to the type of scanner, with the amount of error in terms of trueness being clinically significant.

In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies

  • Ozal, Cise;Ulusoy, Mutahhar
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.373-384
    • /
    • 2021
  • PURPOSE. This study aimed to compare the marginal and internal fit of 3-unit monolithic zirconia restorations that were designed by using the data obtained with the aid of intraoral and laboratory scanners. MATERIALS AND METHODS. For the fabrication of 3-unit monolithic zirconia restorations using impressions taken from the maxillary master cast, plaster cast was created and scanned in laboratory scanners (InEos X5 and D900L). The main cast was also scanned with different intraoral scanners (Omnicam [OMNI], Primescan [PS], Trios 3 [T3], Trios 4 [T4]) (n = 12 per group). Zirconia fixed partial dentures were virtually designed, produced from presintered block, and subsequently sintered. Marginal and internal discrepancy values (in ㎛) were measured by using silicone replica method under stereomicroscope. Data were statistically analyzed by using 1-way ANOVA and Kruskal Wallis tests (P<.05). RESULTS. In terms of marginal adaptation, the measurements on the canine tooth indicated better performance with intraoral scanners than those in laboratory scanners, but there was no difference among intraoral scanners (P<.05). In the premolar tooth, PS had the lowest marginal (86.9 ± 19.2 ㎛) and axial (92.4 ± 14.8 ㎛), and T4 had the lowest axio-occlusal (89.4 ± 15.6 ㎛) and occlusal (89.1 ± 13.9 ㎛) discrepancy value. In both canine and premolar teeth, the D900L was found to be the most marginally and internally inconsistent scanner. CONCLUSION. Within the limits of the study, marginal and internal discrepancy values were generally lower in intraoral scanners than in laboratory scanners. Marginal discrepancy values of scanners were clinically acceptable (< 120 ㎛), except D900L.