• Title/Summary/Keyword: diesel generator

Search Result 315, Processing Time 0.021 seconds

Mechanical Characteristic Analysis of Coil Spring & Viscous Damper (Coil Spring & Viscous Damper System의 동특성분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.19-26
    • /
    • 2007
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. Through this research nonlinear damping characteristics and the effective stiffness of coil spring and viscous damper system were evaluated.

Development of the Monitoring and Diagnosis Technique on Emergency Diesel Generator System (비상디젤발전기계통 상태감시 및 고장진단기술 개발)

  • Cho, Kwon-Hae;Rhyu, Keel-Soo;So, Myung-Ok;Park, Jong-Il;Son, Min-Su;Ahn, Jong-Kap;Lee, Yun-Hyung;Jang, Tae-Lin
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.777-782
    • /
    • 2005
  • The importance of emergency diesel generator(EDG) has confirmed in the safety evaluation of PSA and the study on aging of EDG has been progressed actively as a part of the project of nuclear plant aging research in the U.S.A. As the result, the concept of performance evaluation is being transferred from statistical analysis of test results to performance monitoring and trending analysis for monitoring of aging and reliability. Recently, the study related aging characteristic and reliability for EDGS has begun in Korea. Consequently, the efficient performance monitoring based systematic and integrated monitoring and failure diagnostic technology is necessary. In the research, the knowledge basis of monitoring parameters for EDGS is constructed, and the prototype monitoring and diagnosis system applicable to Pielstick EDG is developed.

  • PDF

Electromagnetic Field Analysis of 230 kW-class Low Wind Speed Medium Wind Turbine for Island-area Application (도서지역 적용을 위한 230 kW급 저풍속 중형 풍력발전기의 전자장해석)

  • Choi, Mansoo;Choi, Hyewon;Lee, Changmin;Choi, Hyenjun
    • New & Renewable Energy
    • /
    • v.16 no.2
    • /
    • pp.14-19
    • /
    • 2020
  • Recently, a project to build a carbon zero island with no carbon emissions has been carried out by replacing diesel generators with renewable energy sources in island areas where diesel generators supplied local loads as independent systems. To minimize damage to the lives of islanders, low noise wind generators should be installed by adjusting the rated speed. In islands with low loads, wind turbines that are more efficient than medium-sized wind turbines should be installed. In this study, the generator field analysis and characteristics were analyzed to develop 230 kW-class low wind medium-wind turbine technology. The electromagnetic field analysis program used Maxwell. As a result, the cogging torque was reduced, and the initial maneuver wind speed and loss value were lowered. Hence, the output amount was increased with high efficiency.

Operational Availability Improvement through Online Monitoring and Advice For Emergency Diesel Generator

  • Lee, Jong-Beom;Kim, han-Gon;Kim, Byong-Sub;M. Golay;C.W. Kang;Y. Sui
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.264-270
    • /
    • 1998
  • This research broadens the prime concern of nuclear power plant operations from safe performance to both economic and safe performance. First emergency diesel generator is identified as one of main contributors for the lost plant availability through the review of plants forced outage records. The framework of an integrated architecture for performing modern on-line condition for operational availability improvement is configured in this work. For the development of the comprehensive sensor networks for complex target systems, an integrated methodology incorporating a structural hierarchy, a functional hierarchy, and a fault-system matrix is formulated. The second part of our research is development of intelligent diagnosis and maintenance advisory system, which employs Bayesian Belief networks (BBNs) as a high level reasoning tool incorporating inherent uncertainty use in probabilistic inference. Our prototype diagnosis algorithms are represented explicitly through topological symbols and links between them in a causal direction. As new evidence from sensor network development is entered into the model especially, our advisory of system provides operational advice concerning both availability and safety, so that the operator is able to determine the likely modes, diagnose the system state, locate root causes, and take the most advantageous action. Thereby, this advice improves operational availability

  • PDF

Development of the High Power Battery Charging System for Portable Energy Banks (이동식 에너지 뱅크용 대용량 배터리 충전 시스템의 개발)

  • Kim, Soo-Yeon;Kim, Dong-Ok;Lee, Jung-Hwan;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.491-499
    • /
    • 2021
  • Batteries are widely used for energy storage, such as ESS(Energy Storage System), electric vehicles, electric aircraft, and electric powered ships. Among them, a submarine uses a high power battery for an energy storage. When the battery of a submarine is discharged, a diesel generator generates AC power, and then AC/DC power converter change AC power to DC power for charging the battery. Therefore, in order to lower the current capacity of the diesel generator, it is necessary to use an AC/DC converter with a high input power factor. And, a power converter with a large power capacity must have high stability because it can lead to a major accident when a failure occurs. However, the control algorithm using the traditional PI controller is difficult to satisfy stability and dynamic characteristics. In this paper, we design the high power AC/DC converter with high input power factor for battery charging systems. And, we propose a stable control algorithm. The validity of the proposed method is verified through simulation and experiments.

An Application of Harmony Search Algorithm for Operational Cost Minimization of MicroGrid System (마이크로 그리드 운영비용 최소화를 위한 Harmony Search 알고리즘 응용)

  • Rhee, Sang-Bong;Kim, Kyu-Ho;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1287-1293
    • /
    • 2009
  • This paper presents an application of Harmony Search (HM) meta-heuristic optimization algorithm for optimal operation of microgrid system. The microgrid system considered in this paper consists of a wind turbine, a diesel generator, and a fuel cell. An one day load profile which divided 20 minute data and wind resource for wind turbine generator were used for the study. In optimization, the HS algorithm is used for solving the problem of microgrid system operation which a various generation resources are available to meet the customer load demand with minimum operating cost. The application of HS algorithm to optimal operation of microgrid proves its effectiveness to determine optimally the generating resources without any differences of load mismatch and having its nature of fast convergency time as compared to other optimization method.

Optimization of Residential Photovoltaic-Fuel Cell Hybrid System Using HOMER(R) (HOMER를 이용한 가정용 태양광-연료전지 하이브리드시스템의 운전 최적화)

  • Park, Se-Joon;Li, Ying;Choi, Young-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.129-133
    • /
    • 2010
  • A hybrid system which is combined several complementary new and renewable power sources, such as photovoltaic, fuel-cell, and wind generator, etc., has been presented in various approaches. For instance, a photovoltaic cannot always generate stable output power with ever-changing weather condition, so it might be co-generated with a wind generator, diesel generator, and some other sources. In this paper, a residential PV-FC hybrid system is suggested as a distribution power source, and its operation is optimized by HOMER$^{(R)}$. As a result, it is the most economic that 5[kW] PV, 1[kW] FC, 4 batteries, 2[kW] electrolyzer, 0.5[kg] $H_2$ tank, 3[kW] converter are applied to the hybrid system.

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant (화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구)

  • Lee, Seung-Jae;Jo, Man-Young;Kim, Se-Yong;Kim, Eun-Tae;Kang, Byoung-Wook;Park, Han-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

Study on Prediction of Performance with Design Variables of Solar-Assisted Still Using Waste Heat from Diesel Generator (디젤 발전기 폐열을 활용한 태양열원 해수담수기의 설계변수에 따른 성능 예측에 관한 연구)

  • Jang, Hyun;Yi, Chung Seob;Suh, Jeong Se;Jeong, Kyoung Yul;Park, Change Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1061-1068
    • /
    • 2013
  • This study predicts distillate productions according to design variables by numerical analysis when the waste heat from a diesel generator is added to the solar-assisted still proposed in a previous study. Mathematical models were set up in reference to previous studies, and the amount of heat exchange from the waste heat recovery pipe was considered. To ensure the reliability of numerical analysis, the result was compared with that of a previous study and then, the distillate productions according to design variables were obtained by the analysis model. The results were found to generally be in agreement, and the increasing amount of distillate production of the still with the added waste heat was confirmed. In addition, the optimal value of the tilt angle of glass cover and the number of cells were determined by numerical analysis.