• 제목/요약/키워드: diesel generator

검색결과 315건 처리시간 0.026초

HOMER 프로그램을 이용한 독립형 하이브리드 발전시스템 최적화 (Optimization of Stand-Alone Hybrid Power Systems Using HOMER Program)

  • 양수형;부창진;김호찬
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.11-18
    • /
    • 2012
  • Diesel fuel is expensive because transportation to remote areas adds extra cost, and it causes air pollution by engine exhaust. Providing a feasible economical and environmental solution to diesel generators is important. A hybrid system of renewable plants and diesel generators can benefit islands or other isolated communities and increase fuel savings. Renewable energy is, however, a natural source that produces a fluctuating power output. In this paper, hybrid power system of the marado lighthouse is proposed to supply stable power in the stand-alone hybrid power system. The proposed hybrid power system consists of the diesel generator, wind turbine, photovoltaic, fuel cell, and battery bank. To decrease the carbon emissions and find the optimization, the cost analysis of hybrid system is simulated using HOMER program and the optimized hybrid power system is designed.

독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션 (Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power)

  • 강상균;이은규;이장호
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

저속 2행정 디젤엔진과 직결된 축발전기의 비틀림 진동 특성 (Torsional Vibration Characteristics of Shaft Generating System Direct-coupled with Low-speed Two Stroke Diesel Engine)

  • 로날드 디 바로;김홍렬;트릉헝 남;이돈출
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.14-19
    • /
    • 2017
  • Fuel oil consumption cost varies depending on every ship operation and this roughly amounts to 70 % of shipping companies' total revenue. As such, efforts towards improved fuel economy are being pursued. An annual 1 % reduction in fuel consumption is perceived to result in saving tens million US dollars on the global fleet operation. One approach is the application of power take-off configurations which are seen to increase fuel oil economy and are suitable for power generation. In this study, the dynamic properties of a shaft generator coupled on a 10S90ME main engine of an 18 600 TEU container vessel is presented. The vibratory torque and angular velocity variation was examined through theoretical analysis and actual vibration measurement. The result of the study suggests a review on existing classification rules for generator design and the lowering of vibratory torque and angular velocity variation guideline.

Modeling of Solar/Hydrogen/DEGS Hybrid System for Stand Alone Applications of a Large Store

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.57-68
    • /
    • 2013
  • The market for distributed power generation based on renewable energy is increasing, particularly for standalone mini-grid applications in developing countries with limited energy resources. Stand-alone power systems (SAPS) are of special interest combined with renewable energy design in areas not connected to the electric grid. Traditionally, such systems have been powered by diesel engine generator sets (DEGS), but also hybrid systems with photovoltaic and/or wind energy conversion systems (WECS) are becoming quite common nowadays. Hybrid energy systems can now be used to generate energy consumed in remote areas and stand-alone microgrids. This paper describes the design, simulation and feasibility study of a hybrid energy system for a stand-alone power system. A simulated model is developed to investigate the design and performance of stand-alone hydrogen renewable energy systems. The analysis presented here is based on transient system simulation program (TRNSYS) with realistic ventilation load of a large store. Design of a hybrid energy system is site specific and depends on the resources available and the load demand.