• Title/Summary/Keyword: diameter control

Search Result 2,248, Processing Time 0.032 seconds

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

Development of Ocean Data Buoy and Real-Time Monitoring Technology (종합관측부이 개발 및 실시간 관측기술)

  • 심재설;이동영;박우선;박광순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.1
    • /
    • pp.56-67
    • /
    • 1999
  • It is desired to use a domestically manufactured ocean data buoy for the long-term operational ocean monitoring. The ocean data buoy manufacturing technology was introduced through the research cooperation with the Qingkong University of Taiwan. The introduced ocean data buoy system was further expanded and improved for more efficient application for the marine environmental monitoring in Korea. The size of the ocean data buoy is 2.5 m in diameter, which is smaller compared to the NOAA's 3.0 m discus buoy to allow easy land transportation and ocean deployment as well. From the dynamic response test of the buoy carried out numerically, it was shown that the measurement of waves with period greater than 4 seconds is acceptable. The measurement and control system of the data buoy were improved to increase the number of measuring parameters, to reduce power consumption and to enhance better data analysis and management. Each component of the improved data buoy system was described in detail in this paper. Water quality sensors of water temperature, salinity, DO, pH and turbidity were added to the system in addition to the marine meteorological sensors of wind speed and direction, air temperature, humidity, air pressure and wave. Inmarsat satellite communication system is used for the real-time data telemetry from the buoy deployed offshore. A field performance test of the improved and domestically manufactured buoy was carried out for a month at the open sea off Pohang together with DatawelI's Wave-rider buoy to compare the wave data. The results of the test were satisfactory.

  • PDF

ELECTRON MICROSCOPIC STUDY OF RESIN-DENTIN HYBRID ZONE PRODUCED BY THE MOISTENING OF ACID CONDITIONED DENTIN SURFACE (산 표면처리 후 상아질 표면의 습윤이 하이브리드층 형성에 관한 전자현미경적 연구)

  • Lee, Kwang-Won;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.463-486
    • /
    • 1995
  • The effect of moistening and air-drying of acid-conditioned dentin before priming on the formation of resin-dentin hybrid zone was investigated, Freshly extracted human molars were used and divided at random into 5 groups, Groups 1 - 3 consisted of specimens conditioned with 10 % phosphoric acid for 20 seconds; Group 1 served as a control in which the conditioned dentin was simply blot-dried with a damp facial tissue; Group 2 was air dried for 30 seconds ; Group 3 was air dried for 30 seconds and immediately remoistened for 10 seconds with air-water syringe. and then the specimen was blot-dried with a damp facial tissue. Groups 4-5 were not acid conditioned ; In group 4, the smear layer on the dentin was blot dried before primer placement; Group 5 was air dried only for 30 seconds, The acetone-based primer and bonding agent of All Bond 2 (Bisco. Inc., USA) and composite resin (Z-100, 3M Dental products, USA) were applied for acid conditioned dentin and non-conditioned dentin. The morphologic ultrastructure of resin-dentin hybrid zone was examined by the use of SEM and TEM. and the existence of inorganic material and analysis of Ca/P weight-percent ratio in the resin-dentin hybrid zone were revealed by the EDAX, The results were as follows : 1. In the moistened specimens from acid-conditioned groups, the resin penetrated about 3-$4{\mu}m$ into dentin and the denatured collagen smear layer was not present at the surface. The resin tag was formed to a thickeness of 3-$4{\mu}m$ at the upper part of dentinal tubule and compactively connected to each other by means of many lateral branching. 2. In the air-dried specimens from acid-conditioned groups, the resin penetrated about 2.0-$2.5\;{\mu}m$ into dentin and an upper thin black layer to a thickness of 30-35nm was identified between adhesive resin and demineralized collagen layer. The resin tag to have a diameter of $2.5{\mu}m$ was formed at the upper part of dentinal tubule. However the funnel shape of the tag was not notable compared to the moistened specimens. 3. In the remoistened specimens from acid conditioned groups, the resin penetrated about 2.0-$2.5{\mu}m$ into dentin and an upper black layer was not present. The resin tag at the upper part of dentinal tubule was formed less than $2{\mu}m$ and was weakly connected to each other by means of few lateral branching. 4. In the non-conditioned groups, the smear layer was formed to a thickness of $0.5{\mu}m$ at dentin surface. However, the resin-dentin hybrid zone was not identified by TEM. The evidence of resin penetration into intertubular and intratubular dentin did not show. 5. All the acid-conditioned groups showed that the detected calcium and phosphorus weight percent ratios at the $2{\mu}m$ upper portion from the resin-dentin interface into the resin were much higher than that at the $2{\mu}m$ lower portion from the resin-dentin interface to dentin. (P<0.01).

  • PDF

The evaluation of surface roughness and polishing time between polishing systems (연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가)

  • Kim, Ye-Mi;Shin, Su-Jung;Song, Min-Ju;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan's multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.

An Experimental Study on the Effect of Combined X-ray and Microwave Hyperthermia on the Rectum and Urinary Bladder of Rats (흰쥐의 직장과 방광에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.115-128
    • /
    • 1986
  • Hyperthermia can enhance the radiation effect as a synergistic reaction in combined X-ray irradiation and hyperthermia; hyperthermia sensitize radioresistant S-phase cells and inhibit cellular recovery from sublethal damage. We fabricated 100 watts, 2450 MHz microwave applicator for hyperthermia and planned the method and condition of heating and measured the temperature by using Agar phantom as a preliminary test. For biological examination, 102 rats were divided into 4 groups as hyperthermia, X-ray irradiation (6Gy-15Gy), combined X-ray and hyperthermia, and normal control groups. Microscopic examination of the rectum and bladder was done and the results were as followings: 1. The microwave generator with 100 watts, 2450MHz magnetron could be heating up to $40^{\circ}{\sim}50^{\circ}C$ for one hour in living tissue. 2. The thermal distribution in tissue equivalent phantom with microwave can be maintained at $40^{\circ}{\sim}44^{\circ}C$ in area of 3cm in depth and 2-10cm in diameter. 3. In Hyperthermia alone group, there was submucosal edema of the rectum but no histologic change in the urinary bladder was seen. 4. The minimal necrosis of the mucosa was appeared in the rectum and bladder after 15 days of 6 Gy and 8 Gy irradiation respectively. The minimal necrosis of the muscle layer of rectum and bladder was appeared after 15 days of 8Gy and 60days of 10Gy irradiation respectively. 5. In combined group of radiation and hyperthermia, thermal enhancement ratio (calculated at necrosis of mucosa and muscle layer) of rectum and bladder was 1.0, and it suggest that there is no change of tolerance dose of normal rectum and bladder.

  • PDF

Bactericidal Efficacy of Non-thermal DBD Plasma on Staphylococcus aureus and Escherichia coli (비열 유전체장벽방전 플라즈마의 포도상구균 및 대장균 살균효과)

  • Kim, Keyyoung;Paik, Namwon;Kim, Yonghee;Yoo, Kwanho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.61-79
    • /
    • 2018
  • Objectives: The objective of this study was to examine the effect of non-thermal dielectric barrier discharge(DBD) plasma on decontamination of Staphylococcus aureus(S. aureus) and Escherichia coli(E. coli) as common pathogens. Methods: This experiment was carried out in a chamber($0.64m^3$)designed by the authors. The plasma was continuously generated by a non-thermal DBD plasma generator(Model TB-300, Shinyoung Air tech, Korea). Suspensions of S. aureus and E. coli of 0.5 McFarland standard($1.5{\times}10^8CFU/mL$) were prepared using a Densi-Check photometer(bio $M{\acute{e}}rieux$, France). The suspensions were diluted1:1000 in sterile PBS solutions(approximately$10^{4-5}CFU/mL$) and inoculated on tryptic soy agar(TSA) in Petri dishes. The Petri dishes(80mm internal diameter)were exposed to the non -thermal DBD plasma in the chamber. Results: The results showed that 95% of S. aureus colonies were killed after a six-hour exposure to the DBD plasma. In the case of E. coli, it took two hours to kill 100% of the colonies. The gram-negative E. coli had a greater reduction than the gram-positive S. aureus. This difference may be due to the structure of their cell membranes. The thickness of gram-positive bacteria is greater than that of gram-negative bacteria. The S. aureus is more resistant to DBD plasma exposures than is E. coli. It should be noted that average concentrations of ozone, a byproduct of the DBD plasma generator, were monitored throughout the experiment and the results were well below the criteria, 50 ppb, recommended by the Korean Ministry of the Environment. Thus, non-thermal DBD plasma is deemed safe for use in hospital and public facilities. Conclusions: There was evidence that non-thermal DBD plasma can effectively kill S. aureus and E. coli. The results indicate that DBD plasma technology can greatly contribute to the control of infections in hospitals and other public and private facilities.

A New Spray Chrysanthemum Cultivar, 'Blue Hope' with Anemone Type and White Petals for Cut Flower (백색 아네모네형 절화용 스프레이국화 '블루호프' 육성)

  • Hwang, Ju-Chean;Chin, Young-Don;Chung, Yong-Mo;Kim, Su-Kyeong;Ro, Chi-Woong;Jeong, Byoung Ryong
    • Horticultural Science & Technology
    • /
    • v.31 no.1
    • /
    • pp.123-127
    • /
    • 2013
  • A new spray chrysanthemum (Dendranthema grandiflorum) 'Blue Hope' was bred by the Flower Research Institute, Gyeongsangnam-do Agricultural Research & Extension Services in 2009. The cultivar 'Blue Hope' was initially derived from the cross in 2005 between 'Ford', a spray chrysanthemum cultivar, with white anemone type, and 'Chopin', a spray chrysanthemum cultivar with white anemone type. The cultivar has anemone type with white petals. After the evaluation of the characteristics under shade culture in summer and retarding culture in spring and consecutive selection from 2007 to 2009, 'Blue Hope' was selected finality. The natural flowering time of 'Blue Hope' was October 24th, and year-round flowering is possible by shading or lighting treatment. The growth of plant was very vigorous and response time 6.5 weeks. The diameter of flower was 4.9 cm. Number of flowers per stem was 19.1 in autumn. Days to flowering under the short day treatment was about 45 in spring and its vase life was 23.8 days in the autumn season. This cultivar was resistance white rust and consumer's preference of new spray is high level than the control.

A Study on Removal Efficiency of VOCs using Vortex Cyclones (보텍스 사이클론을 이용한 VOCs 제거효율에 관한 연구)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-199
    • /
    • 2005
  • The principle of vortex cyclone was applied to enhance the treatment efficiency of waste air streams containing particulate matters, phenol, and others. Adsorption, condensation, and/or coagulation could be induced at low temperature zone formed by Joule-Thomson expansion as the pressurized air and pulverized activated carbon were introduced at the tangential direction into the cyclone system applied with the coaxial funnel tube of vortex cyclone. Easily condensible vapors were adsorbed and/or condensed forcibly on coagulated or condensed materials which were formed as cores for coagulation or condensation by themselves or on pulverized activated carbons. These types of coagulation or condensation rates were rapidly promoted by increase in their diameter. The maximum removal efficiency obtained from this experiment for the removal of carbon dioxide and phenol was about 87.3 and 93.8 percent, respectively. Phenol removal efficiency was increased with the relative humidities and enhanced by pulverized activated carbon added. The Joule-Thomson coefficients were increased with the pressure of air injected in the range of the relative humidities between 10% and 50%. It is believed that the moisture, particulate matters, and the pressure of the process air introduced could control the removal efficiency of VOCs.

Effect of Cultivation Method, Harvest Season and Preservative Solution on the Quality and Vase Life of Cut Rose 'Rote Rose' (롯데로제 장미의 재배방법, 수확시기 및 보존제 종류가 절화 품질과 수명에 미치는 영향)

  • Cho, Mee Sook;Hwang, Seung Jae;Jeong, Byoung Ryong
    • Horticultural Science & Technology
    • /
    • v.19 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • Experiments were conducted to evaluate quality and vase life of cut rose 'Rote Rose' cultivated in soil or hydroponically in rockwool. Rose flower stems harvested in commercial greenhouses in Kimhae on May 27 and June 14, 1998 were transported for about two hours to a laboratory and recut in water to an uniform stem length of 45cm. The rose flowers harvested on the same day were displayed at a density of $10cm{\times}10cm$ and were subjected to the same environmental conditions in a growth chamber. The stems were put in four different preservative solutions, 0.5% Chrysal RVB, BS (2% sucrose+200ppm 8HQS+0.3% Chrysal RVB), Sonk1 (BS+0.1mM ethionine), and double distilled $H_2O$. Flower stems harvested on May 27 were displayed at $18{\pm}1^{\circ}C$, RH 60-70%, and light intensity of 220lux provided by fluorescent lamps for $16h{\cdot}d^{-1}$. Flower stems harvested on June 14 were displayed at $25{\pm}1^{\circ}C$, RH 70-80%, and light intensity of 220lux provided by fluorescent lamps for $16h{\cdot}d^{-1}$. Fresh weight and flower diameter were affected by cultivation method, and were greater in hydroponically-grown roses than in soil-grown roses. Among the preservative solutions, BS and Sonk1 were superior to Chrysal RVB in terms of prolonging vase life. Vase life extension in Chrysal RVB, BS and Sonk1 over the control was about one day in both display temperatures. At $18^{\circ}C$ vase life was maintained for three to four additional days as compared to that at $25^{\circ}C$.

  • PDF

Stereotactic LINAC Radiosurgery of Meningiomas (선형가속기를 이용한 뇌수막종의 뇌정위적 방사선수술)

  • Ryu, Kyung-Sik;Son, Byung-Chul;Kim, Moon-Chan;Suh, Tae-Suk;Kay, Chul-Seung;Yoon, Sei-Chul;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.317-323
    • /
    • 2000
  • Objective : To evaluate the role of stereotactic LINAC radiosurgery in treatment of meningiomas, the authors retrospectively analyzed the result of radiosurgery in our institute. Method: During last ten years, twenty patients underwent stereotactic LINAC radiosurgery(LINAC SRS) for meningiomas. The mean age of the patients was 51 years(22-78 years). The most common tumor location for radiosurgery was parasagittal, sphenoid wing and tentorial area. With regards to indications of radiosurgery for meningiomas, LINAC radiosurgery was done for primary treatment in six patients, for postoperative residual tumors in eleven patients, for postoperative regrowth in three patients. Mean tumor volume was $5.14cm^3$($0.28-15.1cm^3$), mean field diameter was 2.01cm(1.2-3cm). The mean marginal dose was 20.55Gy(13-30Gy). The follow-up evaluation was done annually with radiologic findings and clinical status. The mean follow-up period was 46.8(24-120) months. Result : In the radiologic response, the tumor volume was reduced in five(25%) of twenty patients, fourteen showed arrested growth(70%), but one patient showed increased growth(5%). In the clinical response, nine patients improved clinically(45%), ten patients was stable(50%) and one patient worsened during follow-up period. With regards to correlation with radiologic and clinical response, in nineteen patients who showed radiologic response to radiosurgery(decreased and arrested growth after radiosurgery), nine patients(47.4%) improved and ten patients (52.6%) showed no change, one patient(5%) had symptomatic radiation necrosis at four years after SRS, which needed craniotomy. Conclusion : The overall control rate of meningiomas with LINAC radiosurgery was 95% in radiologic follow up and 95% clinically. The radiation complication rate was 5%. These results indicate that LINAC radiosurgery can be considered as safe and effective method for meningiomas.

  • PDF