• Title/Summary/Keyword: diameter

Search Result 18,918, Processing Time 0.043 seconds

Geometric Error Analysis of Contact Type Three Points Supporting Method for Inner Diameter Measurement (접촉식 3점지지법에 의한 내경측정의 기하학적 오차 해석)

  • Kim, Min-Ho;Kim, Tae-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.69-76
    • /
    • 2008
  • Inner diameter of bearing race is automatically measured by complete inspection system after grinding process. Contact type three points supporting method is widely applied to automatic inner diameter measurement because of its excellent stability. However, the geometric consideration regarding three points supporting method is not sufficient. In this study, the error equation from geometric error analysis of three points supporting method is found. The effect of factors in the error equation is also investigated. The error equation is linear for difference of diameter in sample and master on range of tolerance. An error becomes more and more larger, when the distance of two supporting balls or the diameter of supporting ball are increased. In the result, some considerations are proposed for measurement of inner diameter by the three points supporting method.

DIAMETER Protocol (DIAMETER 프로토콜)

  • Kim, S.C.;Jeon, H.S.;Kim, S.H.
    • Electronics and Telecommunications Trends
    • /
    • v.16 no.1 s.67
    • /
    • pp.24-35
    • /
    • 2001
  • AAA는 복잡한 Inter-domain 응용 서비스의 등장으로 인해 이들 서비스들을 신뢰성 있고 안전하게 관리하기 위해 사용된다. IETF에서는 AAA를 위해 Remote Authentication Dial-In User Service(RADIUS)와 DIAMETER 프로토콜을 제안하고 있다. DIAMETER는 기존의 PPP와 Roaming, Mobile IP 같은 새로 출현하는 정책과 AAA 서비스를 위한 확장 기능을 제공하기 위한 Peer 기반의 가벼운 AAA 프로토콜이다. 본 논문에서는 DIAMETER 프로토콜에 대한 개요 및 메시지, 형식, 그리고 라우팅 방식에 대해서 기술한다.

Effect of Sediment Size On Air Injection and Flowing Aspect of Groundwater Saturated Zone (대수층 토양입자크기에 따른 공기분사 흐름 양상)

  • 이준호;박갑성
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 2003
  • Laboratory scale study for an air injection and flowing aspect of groundwater saturated zone was conducted for three sediment grains (AMG 0.34, 1.38, 3.89 mm diameter). Air flow for AMG (Average Modal diameter Grains) 0.34 mm diameter grain size provides indication of pattern of channelized air flow in saturated zone and expansion state in above saturated zone. Maximum area of influence is approximately l5.2%/$\textrm{m}^2$for AMG of 0.34 mm diameter. For AMG of 1.38 mm and 3.89 mm modal diameter grains, air flow are pervasive air flow, forming a symmetrical cone of influence around the injection point. Maximum areas affected are 37%/$\textrm{m}^2$for AMG 1.38 mm diameter and 30%/$\textrm{m}^2$for AMG 3.89 mm diameter. AMG 1.38 mm and 3.89 mm diameter grains show onset of collapse and approach to steady state in above saturated zone, respectively. In this study, optimal sites for in situ air sparging, may be grain diameters between about AMG 1.5-2.5 mm diameter.

Fault Diameter and Mutually Disjoint Paths in Multidimensional Torus Networks (다차원 토러스 네트워크의 고장지름과 서로소인 경로들)

  • Kim, Hee-Chul;Im, Do-Bin;Park, Jung-Heum
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.5_6
    • /
    • pp.176-186
    • /
    • 2007
  • An interconnection network can be represented as a graph where a vertex corresponds to a node and an edge corresponds to a link. The diameter of an interconnection network is the maximum length of the shortest paths between all pairs of vertices. The fault diameter of an interconnection network G is the maximum length of the shortest paths between all two fault-free vertices when there are $_k(G)-1$ or less faulty vertices, where $_k(G)$ is the connectivity of G. The fault diameter of an R-regular graph G with diameter of 3 or more and connectivity ${\tau}$ is at least diam(G)+1 where diam(G) is the diameter of G. We show that the fault diameter of a 2-dimensional $m{\times}n$ torus with $m,n{\geq}3$ is max(m,n) if m=3 or n=3; otherwise, the fault diameter is equal to its diameter plus 1. We also show that in $d({\geq}3)$-dimensional $k_1{\times}k_2{\times}{\cdots}{\times}k_d$ torus with each $k_i{\geq}3$, there are 2d mutually disjoint paths joining any two vertices such that the lengths of all these paths are at most diameter+1. The paths joining two vertices u and v are called to be mutually disjoint if the common vertices on these paths are u and v. Using these mutually disjoint paths, we show that the fault diameter of $d({\geq}3)$-dimensional $k_1{\times}k_2{\times}{\cdots}{\times}k_d$ totus with each $k_i{\geq}3$ is equal to its diameter plus 1.

Condensing Heat Transfer Characteristics of R-22 and R-134a in Small Diameter Tubes (세관내 R-22와 R-134a의 응축 전열 특성에 관한 연구)

  • Hong, Jin-U;No, Geon-Sang;Jeong, Jae-Cheon;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2001
  • Condensing heat transfer coefficients of R-22 and R-134a were measured in smooth, horizontal copper tubes with inner diameters of 1.77mm, 3.36mm, and 5.35mm, respectively. The experiments were conducted in the closed loop, which was driven by a magnetic gear pump. Data are presented for the following range of variables : mass velocity from 200 to 500kg/$m^2$.s and quality from 0 to 1.0. The heat transfer coefficients in the small diameter tubes (ID < 7mm) were observed to be strongly affected by various diameters and the heat transfer characteristics in the small diameter tubes differed from those in the large diameter tubes. Heat transfer coefficients in the small diameter tubes are higher than those in the large diameter tubes at the same experimental condition. It was found that some well-known previous correlations(Shahs correlation and Cavallini-Zecchins correlation) were not suitable for small diameter tubes.

Effects of Molecular Weight and Temperature on Fiber Diameter of Poly(ε-caprolactone) Melt Electrospun Fiber

  • Ko, Junghyuk;Jun, Seungwon;Lee, Jason Keonhag;Lee, Patrick C.;Jun, Martin B.G.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.160-165
    • /
    • 2015
  • The 14k, 45k, and 70k Mw PCL have different crystallization temperatures and therefore have slightly different characteristics affecting the fiber diameter. To observe these behaviors, the fiber was produced at every step of $10^{\circ}C$ for each molecular weights and the diameter was measured. Moreover, the fiber was fabricated over the cooled ground plate to observe the change in fiber diameter in comparison to the normal ground plate. In case of molecular Mw 14k PCL, the diameter increased as the temperature increased. For Mw 45k PCL, the fiber diameter decreased as the temperature increased. As of Mw 70k PCL, the fiber diameter decreased with increasing temperature as well. When the experiment was conducted over the cooled collector plate, the data did not change significantly from the previous lexperiments.

A Numerical Study on the Steady and Pulsatile Flow with Various Diameter Ratios of Abdominal Aortic Aneurysm (복부대동맥류의 직경비에 따른 정상유동 및 맥동유동에 관한 수치적 연구)

  • Moh, Jeong-Hah;Park, Sang-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.920-928
    • /
    • 2003
  • The objective of the present study was to investigate the characteristics of flow and wall shear stress under steady and pulsatile flow in the aneurysm. The numerical simulation using the software were carried out for the diameter ratios ranging from 1.5 to 3.0, Reynolds number ranging from 900 to 1800 and Womersley number, 15.47. For steady flow, it was shown that a recirculating vortex occupied the entire bulge with its core located closer to the distal end of the bulge and the strength of vortex increased with increase of the Reynolds number and diameter ratio. The position of a maximum wall shear stress was the distal end of the aneurysm regardless of the Reynolds number and diameter ratios. For the pulsatile flow, a recirculating flow at the bulge was developed and disappeared for one period and the strength of vortex increased with the diameter ratio. The maximum values of the wall shear stress increased in proportion to the diameter ratio. However, the position of a maximum wall shear stress was the distal end of the aneurysm regardless of the diameter ratios.

Cooling Heat Transfer Characteristics of CO2 in a Brazing Type Small Diameter Copper Tube (브레이징식 동세관내 CO2의 냉각 열전달 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.827-834
    • /
    • 2009
  • The cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a $CO_2$ compressor, a mass flow meter, an evaporator and a brazing type small diameter tube as a test section. The mass flux of $CO_2$ is $400{\sim}1600$ [kg/$m^2s$], the mass flowrate of coolant were varied from 0.15 to 0.3 [kg/s], and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The cooling heat transfer coefficients of the brazing type small diameter copper tube is about $4{\sim}11.7%$ higher than that of the conventional type small diameter copper tube. In comparison with test results and existing correlations, correlations failed to predict the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube. therefore, it is necessary to develope reliable and accurate predictions determining the cooling heat transfer coefficient of $CO_2$ in a brazing type small diameter copper tube.

Effects of Root Diameter Within Different Root Parts on Ginsenoside Composition of Yunpoong Cultivar in Panax ginseng C. A. Meyer (인삼 연풍의 근 부위별 직경이 진세노사이드 함량에 미치는 영향)

  • Li, Xiangguo;Kang, Sun-Joo;Han, Jin-Soo;Kim, Jung-Sun;Choi, Jae-Eul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.17 no.6
    • /
    • pp.452-457
    • /
    • 2009
  • This study was carried out to investigate the correlation between root diameter and ginsenoside composition of Panax ginseng C. A. Meyer cultivar Yunpoong. Dry matter ratio of main root was a little higher than that of lateral root and fine root, and that was higher by the increase of root diameter in the same root parts. Total ginsenosides composition of main and lateral roots increased by the decrease of root diameter, especially in lateral root. Similar resulted in fine root, but there was no significant difference where root diameter was below 2.5 mm. Except for ginsenoside-$Rg_1$, other ginsenosides component, PDs, PTs and total ginsenosides had highly negative correlation with the root diameter within whole root, main root+lateral root and lateral root+fine root, while $Rg_1$ had positive correlation with the root diameter.

A Study for the Estimation of Joint Diameter Distribution Using the Trace Length Distribution from Cylindrical Window Survey (원통형조사창에서의 절리선 길이분포를 이용한 암반 내 절리직경분포 추정에 관한 연구)

  • Jeon, Ki-Hwan;Song, Jae-Joon;Jo, Young-Do
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.386-393
    • /
    • 2011
  • This study suggests an algorithm for estimating joint diameter distribution in rock mass from the joint trace length distribution around a circular tunnel. For estimating the joint diameter distribution, the concept of Joint Center Volume (JCV) suggested by Song. (2005) was applied and the calculation method of JCV for the cylindrical window survey was developed by using the complete survey method. The estimated joint diameter distribution was verified against the original joint diameter distribution by Monte-Carlo simulation. It was observed that the estimated joint diameter distribution was converged to the original joint diameter distribution with less than 20% of error.