• Title/Summary/Keyword: dialysate

Search Result 51, Processing Time 0.031 seconds

The Effects of the Individual Application of Low Sodium Dialysate on Weight Gain, Blood Pressure, and Intradialytic Side Effects in Patients on Maintenance Hemodialysis (개별적 저나트륨 투석액 적용이 혈액투석 환자의 체중증가, 혈압 및 투석 중 부작용에 미치는 효과)

  • Song, Ji Sook;Kim, Eun Sook;Lee, Yu Na
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.45-56
    • /
    • 2013
  • Purpose: The purpose of this study is to identify the effect of low sodium dialysate (LSD) rather than conventional dialysate on interdialytic weight gain (IWG), blood pressure (BP), and intradialytic side-effects (ISEs) in patients on maintenance hemodialysis (HD). Methods: The study was performed in 43 patients, who were treated in the university hospital over 8 weeks. Each participant's serum sodium set point was measured using dialysate sodium 140 mEq/L during the first 4 weeks. For the next 4 weeks dialysate sodium concentrate (134,136,and138 mEq/L) was provided to each participant but only to an experimental group (EG) (n=22) based on the individual set point, although 140 mEq/L dialysate was given to all of the control group (CG) (n=21). Consequently, outcomes including IWG, BP, and ISE were evaluated. Results: In EG, difference of pre-HD SBP (p=.047) and post-HD serum sodium (p=.006) were significantly decreased compared to CG. Also, ISEs was not more frequent in EG. However, the differences were not statistically significant, IWG (kg & %), pre-HD DBP, post-HD SBP & DBP, and serum osmolality in EG. Conclusion: Individual application of LSD in patients on maintenance hemodialysis is beneficial to decrease pre-HD SBP and post-HD serum sodium without increasing ISE. Therefore, LSD can be better treatment than conventional dialysate.

The Effect of Dialysate Flow Rate on Dialysis Adequacy and Fatigue in Hemodialysis Patients (혈액투석 시 투석액 속도가 투석적절도와 피로에 미치는 효과)

  • Cha, Sun Mi;Min, Hye Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.5
    • /
    • pp.642-652
    • /
    • 2016
  • Purpose: In this single repeated measures study, an examination was done on the effects of dialysate flow rate on dialysis adequacy and fatigue in patients receiving hemodialysis. Methods: This study was a prospective single center study in which repeated measures analysis of variance were used to compare Kt/V urea (Kt/V) and urea reduction ratio (URR) as dialysis adequacy measures and level of fatigue at different dialysate flow rates: twice as fast as the participant's own blood flow, 500 mL/min, and 700 mL/min. Thirty-seven hemodialysis patients received all three dialysate flow rates using counterbalancing. Results: The Kt/V ($M{\pm}SD$) was $1.40{\pm}0.25$ at twice the blood flow rate, $1.41{\pm}0.23$ at 500 mL/min, and $1.46{\pm}0.24$ at 700 mL/min. The URR ($M{\pm}SD$) was $68.20{\pm}5.90$ at twice the blood flow rate, $68.67{\pm}5.22$ at 500 mL/min, and $70.11{\pm}5.13$ at 700 mL/min. When dialysate flow rate was increased from twice the blood flow rate to 700 mL/min and from 500 mL/min to 700 mL/ min, Kt/V and URR showed relative gains. There was no difference in fatigue according to dialysate flow rate. Conclusion: Increasing the dialy-sate flow rate to 700 mL/min is associated with a significant increase in dialysis adequacy. Hemodialysis with a dialysate flow rate of 700 mL/min should be considered in selected patients not achieving adequacy despite extended treatment times and optimized blood flow rate.

Antioxidative Materials in Domestic Meju and Doengjang 3. Separation of Hydrophilic Brown Pigment and Their Antioxidant Activity (재래식 메주 및 된장중의 항산화성 물질에 관한 연구 3. 수용성 갈변물질의 항산화력)

  • 이종호;김미혜;임상선;김성희;김경업
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.4
    • /
    • pp.604-613
    • /
    • 1994
  • Hydrophilic brown pigments(HBPs) produced during fermentation and aging the domestic Meju and Doenjang were separated by dialysis and chromatography , and their antioxidant activity were measured . The chemical properties of HBP were determined by UV and IR spectrophotometry. HBPs contents were found to be 93.1 mg/g and 183.2mg/g in Meju fermentated for 30 days and 80 days , respectively. The ratio of dialysate to diffusate of the HBPs were appeared to be 70 : 30 and 87 :13 in the Meju fermented for 30 days and 80 days, respectively. and the rtio in the Doenjang aged for 60 days was 91 :9 , indicating that dialysate slowly days, respectively, and the ratio in the Doenjang aged for 60 days was 91 : 9, incidatin that dialysate slowly increased by the fermentation . Both portion exhibited strong antioxidant activity, but more stronger antioxidant activity was found in the dialysate. DEAE-celluose column chromatography showed that dialysate contained more materials eluted by 0.01-0.03M HCI solution than 0.01M acetate buffer, but diffusate showed opposite results. The degree of browning reaction and antioxdiant activity found in the fraction eluted by HCI solution was stronger than that of the fraction eluted by acetate buffer. The fraction eluted from DEAE-cellulose column chormatogrphy was further fractionaged by TLC and found that strong antioxidant activity was present in the fractions which did not possess fluorescenece and showed a negative ninhydrin reaction. TLC fractions of HCI eluant in Meju exhibited a strong absorbance at 260-280nm, but most of other fractions did not show any absorbance at UV region. TLC fractions from dialysate and diffusate showed fairly identical IR spectrum with absorbance at 3400cm-1, 2800cm-3000cm -1, 1600cm, -1 1400cm-1 and 1100 cm-1 , however, in addition to these absorbances, the spectrum from HCI eluant of Meju exhibited a strong absorbance at 1750cm , indicating the carbonic acid or carbonate ester.

  • PDF

Growth of Stahylococcus aureus with Defective Siderophore Production in Human Peritoneal Dialysate Solution

  • Park, Ra-Young;Sun, Hui-Yu;Choi, Mi-Hwa;Bae, Young-Hoon;Shin, Sung-Heui-
    • Journal of Microbiology
    • /
    • v.43 no.1
    • /
    • pp.54-61
    • /
    • 2005
  • In this study, we attempted to determine the effects of iron-availability and the activity of the bacterial iron-uptake system (IUS) on the growth of Staphylococcus aureus in human peritoneal dialysate (HPD) solution. A streptonigrin-resistant S. aureus (SRSA) strain, isolated from S. aureus ATCC 6538, exhibited defective siderophore production, thereby resulting in ineffective uptake of iron from low iron-saturated transferrin. The growth of both strains was stimulated in HPD solution supplemented with FeCl_3 and holotransferrin, but growth was inhibited in HPD solution which had been supplemented with apotransferrin and dipyridyl. The SRSA strain grew less robustly than did its parental strain in both iron-supplemented HPD solution and regular HPD solution. These results indicate that iron-availability and siderophore-mediated IUS activity in particular, the ability to produce siderophores and thus capture iron from low iron-saturated transferrin play critical roles in the growth of S. aureus in HPD solution. Our results also indicated that the possibility of using iron chelators as therapeutic or preventive agents warrants further evaluation.

Epithelial to Mesenchymal Transition in CAPD Patients (복막의 섬유화 기전으로서의 상피중간엽전이)

  • Do, Jun-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.10-18
    • /
    • 2006
  • Epithelial to mesenchymal transition (EMT) is an important etiologic factor for the development of peritoneal fibrosis in CAPD patients. Mesothelial cells are main source of trans-differentiated fibroblasts under stress from the bioincompatible peritoneal dialysate. In our study there was no difference in dialysate TGF-${\beta}$ and VEGF between the low and high GDP groups during an initial 12 months. However, after adjusting with D-CA125, the low GDPs group showed a significantly lower D-TGF-${\beta}$/D-CA125 and D-VEGF/CA125 during the initial 12 months. Among the adjusted peritoneal growth factors for CA125, VEGF/CA125 and TGF-b/CA125 were factors significantly associated with greater EMT in this study. Adjustment of the peritoneal growth factor for effluent CA125 (surrogate for mass of HPMCs) revealed significant association with EMT suggesting that the fibroblastoid transition from HPMCs could be affected by the amount of intraperitoneal growth factors (TGF-b, VEGF) per unit mass of HPMCs. There was significant improvement in both cell score and D-CA125 at the sixth and 12th months after switching from a high GDPs solution to a low GDPs solution. Use of icodextrin solution in patients who had average peritoneal transport showed not only better systemic effects such as decreased glucose absorption via dialysate but also preservation of the peritoneum, including less EMT and high mesothelial bulk mass. In conclusion, Therapy with low GDP solution including icodextrin may positively impact preservation of the peritoneal membrane integrity and prevention of peritoneal fibrosis with time on PD.

  • PDF

Acute Subcutaneous Toxicity Study of Syndella Gel, Topical Drug Containing Deproteinised Dialysate of Calf′s Blood and Micronomicin Sulfate in Rats (랫트에 있어서 신델라 겔 (송아지의 제단백혈액추출물: 황산 미크로노마이신=20:1 혼합물)의 피하급성독성시험)

  • 남석우;서동완;안성훈;장만식;최완수;김규봉;우태욱;한정환;홍성렬
    • Biomolecules & Therapeutics
    • /
    • v.4 no.4
    • /
    • pp.411-414
    • /
    • 1996
  • Single subcutaneous administration to S.D rats of both sexes was performed to investigate the acute toxicity of Syndella gel, a new topical drug containing deproteinised dialysate of calf's blood and micronomicin sulfate. $LD_{50}$ values for S. D rats were 23,047 mg/kg for male and 23,725 mg/kg for female. The death occurred within 24 hours after administration at doses over 19,200 mg/kg. The main cause of death seemed to be respiratory disturbance by acute shock. Major general symptoms induced by injection subcutaneously with Syndella gel were underactivity, decreased respiratory rate, salivation, tremor and loss of consciousness. No significant body weight changes and gross findings of internal organs in treatment groups in comparison with those of control groups was observed at any dose levels in Syndella gel.

  • PDF

Skin Irritation Study of the Syndella Gel, Topical Drug Containing Deproteinised. Dialysate of Calf′s Blood and Micronomicin Sulfate Rabbits (토끼에서 신델라 겔(송아지의 제단백혈액추출물: 황산 미크로노마이신=20:1 혼합물)의 피부자극성시험)

  • 남석우;이영진;고영권;장만식;최완수;김규봉;우태욱;한정환;홍성렬
    • Biomolecules & Therapeutics
    • /
    • v.4 no.4
    • /
    • pp.415-418
    • /
    • 1996
  • This study was conducted to investigate the skin irritation toxicity of Syndella gel, a combination topical drug containing a deproteinised dialysate of calf's blood and micronomicin sulfate in the ratio of 20 to 1, in New Zealand White rabbits. In the primary skn irritation test with male New Zealand White rabbits, there was no treatment-related effect on clinical sign, nd body weight was not significantly changed. The Primary Irritation index (PII) was 0.33, indicating that Syndella gel was a mildly irritating formulation.

  • PDF

The Effect of Hypertonic Dialysate on Hemodynamic Parameters (blood pressure, pulse rate, ultrafiltration rate), Interdialytic Weight Gain and the Incidence of Thirst with Hemodialysis Patients (말기신부전증 환자에서 혈액투석액 나트륨 농도가 혈압, 투석간 체중증가 및 갈증에 미치는 영향)

  • Park, Hye Ja;Jang, Eun Jung;Kim, Mi Kyung;Jo, Nam Mi
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.88-98
    • /
    • 2000
  • Hemodialysis(HD)-associated hypotension is a frequent complication, but it is difficult to manage. Until now, several maneuvers have been tried to prevent the HD-associated hypotension. Of these, the sodium content of dialysate was regarded as an important factor for maintaining blood pressure during HD. In this study, we evaluated the effect of hypertonic dialysate on blood pressure, interdialytic weight gain and the incidence of thirst. The study was done for 6 weeks successively with 3 different groups. Each patient was dialysed with 3 different dialysates for 2 weeks: Group I(Conventional HD: sodium concentration: 137 mEq/L), Group II(Hypertonic HD: 147 mEq/L) and Group III (Sequential HD: from 147 to 140 mEq/L). Hemodynamic parameters(blood pressure, pulse rate and ultrafiltration rate), biochemical parameters(hematocrits, blood urea nitrogen, creatinine, osmolality, sodium, potassium, chloride, fasting blood sugar) and complications (interdialytic weight gain & thirsty sensation) were compared among 3 groups. The results were as follows: 1. Decline of systolic blood pressure and diastolic blood pressure at the time of a 3 hour check during hemodialysis was lower in the Group II than Group I and III (p=0.002; p=0.012). and decline of diastolic blood pressure at the time of a 4 hour check during hemodialysis was lower in the Group II and III than Group I (p=0.04). 2. Incidence of hypotensive episodes during dialysis was significantly lower in Group II than group I (p=0.0287). 3. The ultrafiltration in Group III at the time of 1 hour, 2 hour and 3 hour check during hemodialysis was higher than that in Group I and II at the time of 1 hour, 2 hour and 3 hour check during hemodialysis respectively (p=0.0001; p=0.0001; p=0.0004). 4. Interdialytic weight gain was higher in Group I($3.1{\pm}0.8$) than Group I($2.8{\pm}0.8$) and III ($2.9{\pm}0.9$) (p=0.0422). 5. Hematologic and biochemical results were not significantly different among 3 Groups. 6. Frequency of thirst was different in Group I, II and III, $0.05{\pm}0.12$, $0.41{\pm}0.24$and $0.22{\pm}0.29$ respectively (p=0.0259). The results suggest that hypertonic HD was effective in preventing HD-associated hypotension but interdialytic weight gain and thirst sensations were increased as compared with a conventional method. In this situation, sequential HD seems to be an alternative method to minimizes the side effect of hypertonic HD.

  • PDF

Diffusion-Enhanced Modified Hemodialyzer

  • Lee, Kyung-Soo;Lee, Sa-Ram;Mun, Cho-Hae;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.455-460
    • /
    • 2007
  • Flow mismatch between blood and dialysate is invariably encountered during conventional hemodialysis, and this deteriorates diffusive mass transfer. A modification of a conventional dialyzer was conceived to prevent this mismatch. The modified dialyzer includes two independent blood flow regions (central and peripheral regions), which were achieved by redesigning the dialyzer cap. Resultantly, the blood stream was divided into two concentric dialyzer regions. Solutes clearances obtained using the modified dialyzers were compared with those of conventional dialyzers. Solutes clearances by conventional dialyzers were uniform, but solutes clearances by modified dialyzers were found to be dependent on the simulated blood split into dialyzer central and peripheral regions. Maximal clearances using the modified dialyzer were improved by up to approximately 7.6% for urea and 7.3% for creatinine, as compared with those of conventional dialyzers. More optimizations are required for clinical applications, but the finding that blood flowrates through central and peripheral fiber bundles can be easily regulated is encouraging.

Effect of Individual Low Sodium Dialysate on Blood Pressure, Interdialytic Weight Gain, Thirst and Intradialytic Discomfort In End-Stage Renal Disease Patients (개별적 저 나트륨 투석 액 적용이 말기 신부전증 환자의 혈압, 투석 간 체중 증가, 갈증 및 투석 중 불편감에 미치는 영향)

  • Kim, Sangsuk;Choi, Youngsil
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.3
    • /
    • pp.169-177
    • /
    • 2019
  • Purpose: The purpose of this paper was to identify blood pressure, interdialytic weight gain, thirst and intradialytic discomfort in subjects after applying individual low-sodium dialysis fluid (1,2,3 mEq/L) to hemodialysis patients for 12 weeks. Methods: This study was a non-equivalent pre-post design. For 12 weeks, dialysate concentration was maintained at 1 mEq/L or 2 mEq/L or 3 mEq/L based on average sodium concentration of each individual, and the difference was compared after applying individually. Results: Change in blood pressure significantly decreased in the group where in pre-hemodialysis systolic pressure decreased the gradient of sodium concentration in serum sodium and dialysis solution by 2mEq/L. Interdialytic weight gain, and thirst showed significant decrease in all three groups. But in all three groups, intradialytic discomfort among dialysis showed no significant changes. Conclusion: Although application of low sodium dialysis fluid showed no change in intradialytic discomfort, lowered blood pressure, thirst, and interdialytic weight gain, which could be used for individual showing increased interdialytic weight gain and increased blood pressure. There is need for continued study on this.