• 제목/요약/키워드: diagnostic x-ray

검색결과 597건 처리시간 0.031초

영상장치 센서 데이터 QC에 관한 연구 (A study on imaging device sensor data QC)

  • 윤동민;이재영;박성식;전용한
    • Design & Manufacturing
    • /
    • 제16권4호
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안 (Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System)

  • 최준구;김경수;김병기;안남준;김형선;김상건;임시은
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권1호
    • /
    • pp.53-59
    • /
    • 2007
  • 방사선종사자와 환자 및 보호자의 안전을 위해 개정된 진단용방사선발생장치의 안전관리 규칙이 2006년 2월 10일 공포되었다. 이 규칙에는 중환자실, 수술실, 응급실을 제외한 곳의 방사선검사 시 반드시 방사선방어 용칸막이를 설치하도록 하고 있다. 이 연구의 목적은 이동형 진단용방사선발생장치를 안전하게 관리하여, 방사선으로 인한 위해를 방지하고, 환자 및 보호자들로부터 발생될 수 있는 고객 불만사항들을 최소화 하는데 있다. 조사대상은 병실 이동형 방사선검사환경과 본원의 의료정보시스템(KIS) 및 의료영상전송시스템(PACS)의 통계 데이터를 조사하였다. 그리고 병실 이동형 방사선검사 시 환자 상태 및 감염 등 관련 정보를 조사하여 자료화 하였다. 자료 분석을 통한 이동형 방사선검사에 대한 개정된 규칙을 적용할 경우 고려되는 문제점은 공간적인 측면에서의 제약, 운영적인 측면에서의 인력 및 비용, 업무적인 측면에서 환자 및 보호자 만족도저하 등의 문제가 예상되었다. 따라서 위와 같은 문제를 해결하기 위해 다인병실의 검사를 제한하고, 각 병동에 있는 치료실을 이용하여 검사하도록 하였다. 그 결과 전체 병실 이동형 방사선검사율이 50% 가까이 감소하였고, 거동이 양호한 환자의 병실 이동형 방사선검사율도 85% 이상 감소하였다. 이 결과는 새로운 법 규정에 따라 예상되는 인력, 비용, 고객만족도 저하의 문제들을 해결할 수 있는 대안이 될 수 있었다. 또한 병실 이동형 방사선검사로 인한 환자 및 보호자를 방사선노출로부터 보호하고, 검사로 인한 주위 환자 및 보호자의 불편을 최소화하는데 의의가 있다.다. 6. 성별에 따른 질환의 종류는 남자가 여자보다 pulmonary nodule이 많았고, 여자는 남자보다 cardiomegaly와 tortous aorta, scoliosis가 더 많았다. 7. 연령에 따른 질환의 종류는 35세 미만이 다른 연령대보다 scoliosis가 많았고, $40{\sim}49$세는 CP angle blunting, $35{\sim}39$세는 pulmonary nodule, 50세 이상은 cardiomegaly와 tortous aorta가 많았다. 수 있으리라고 사료된다.이었고(p<0.01) 포장에 대해서는 주택형태에 따라 농가나 아파트에 거주하는 주부가 단독주택이나 연립주택에 거주하는 주부보다 더 나쁘게 평가하는 경향이었다. (p<0.05) (9) 조사대상주부들은 시판제품의 가장 개선해야 할 점으로 위생성(37.0%), 가격(23.8%), 포장(15.6%), 맛(11.1%), 저장성(10.1%) 및 색(2.4%) 등의 순으로 지적하였고 주부의 거주지에 따라 대도시에 거주할수록 위생성을, 농어촌에 거주할수록 가격을 가장 개선해야 할 점으로 보는 경향이었다. (p<0.05)3.2%는 채소에는 cholesterol이 함유되어 있지 않으므로 채식이 건강에 좋다고 하였다. 또한 질병치료에 유효한 채소는 당근 등 42가지, 질병을 유발시키는 채소는 고사리 등 10종을 지적하였으며 이들은 과학적 증명이 가능하거나 민간요법으로 전해지고 있는 내용이다. 이상과 같이 덕성여자대학교 평생교육원에 다니는 주부의 채소 소비 형태에 대하여 살펴보았는데

  • PDF

진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향 (The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment)

  • 최인석;김정민;정회원;민정환;이인수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.1-15
    • /
    • 2009
  • 진단용엑스선장치의 방사선방어 관한 내용을 중심으로 국내 외 규격을 살펴보고 신-구 IEC규격을 비교하여 본 결과는 다음과 같다. 가장 최근에 발표된 IEC 60601-1-3 ; 2008 2nd Edition에 담긴 철학은 크게 두 가지로서, 제조된 진단용 엑스선장치에 의하여 촬영 받게 될 환자를 위하여 어떤 종류의 방사선(선질 : Radiation Quality)을 얼마나 주었는지(선량 : Radiation Dose)를 확실히 해야 한다는 것이며 또 그 장치를 이용하는 작업자를 위하여 누설방사선(Leakage Radiation), 잉여방사선(Residual Radiation), 떠돌이 방사선(Stray Radiation)을 최소화해야 한다는 것이다. 진단용 엑스선장치에 관한 국내규격을 개정하거나 다시 제정할 경우 다음과 같은 내용과과정이 필요하다고 사료된다. 1. 가급적 최신 개념이 담긴 국제규격(IEC Publication)에 맞추되 우리나라의 실정에 맞는 규격을 채택하여야 할 것이다. 즉 IEC 60601-1-3 ; 2008을 근간으로 하고 미국의 CFR, 일본의 JIS도 참고한다면 지금 보다 한층 진보한 규격을 만들 수 있을 것이다. 2. 방사선안전부분을 중점적으로 고시하는 것이 간결하다. 즉 전기 기계적 안전에 관한 사항(IEC 60601-1)은 식품의약품안전청 고시 제 2006-7호 "의료기기의 전기 기계적 안전에 관한 공통기준규격"을 준용해야 한다. 3. 급격한 고시의 변화는 바람직하지 않다. 즉 최근에 개정된 IEC 60601-1-3 ; 2008을 도입하여 바로 적용하지 않고, 일단 현 규격을 일부 개정하여 사용하면서 적응기간을 가질 필요가 있다.

  • PDF

구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

진단용 X선 기기의 선질 분석 (Radiation Quality Analysis of Diagnostic X-ray Equipment)

  • 김태곤;김영표;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.771-772
    • /
    • 2010
  • 환자의 진단에 유용하게 사용되고 있는 X선 장치는 X선을 인체에 조사할 때 나타나는 피폭이 큰 단점으로 지적되고 있으며 ICRP에서는 인체의 방사선 노출 허용량을 제한하고 있다. 이러한 피폭을 줄이기 위해 많은 연구 개발이 진행되고 있다. 본 연구에서는 X선의 발생 효율 증가 및 정밀한 출력 제어가 가능한 인버터 방식의 고전압 발생장치를 제작하였다. 또한 X선관에 인가되는 직류 고전압에 발생 가능한 리플을 최소화하기 위해 전파 정류방식을 적용하였으며, 이를 환자의 진단에 사용하기 위해 조사재현성 및 선질을 평가하였다.

  • PDF

Nested Case-control Study of Occupational Radiation Exposure and Breast and Esophagus Cancer Risk among Medical Diagnostic X Ray Workers in Jiangsu of China

  • Wang, Fu-Ru;Fang, Qiao-Qiao;Tang, Wei-Ming;Xu, Xiao-San;Mahapatra, Tanmay;Mahapatra, Sanchita;Liu, Yu-Fei;Yu, Ning-Le;Sun, Quan-Fu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권11호
    • /
    • pp.4699-4704
    • /
    • 2015
  • Medical diagnostic X-ray workers are one occupational group that expose to the long-term low-dose external radiation over their working lifetime, and they may under risk of different cancers. This study aims to determine the relationship between the occupational X-ray radiation exposure and cancer risk among these workers in Jiangsu, China. We conducted Nested case-control study to investigate the occupational X-ray radiation exposure and cancer risk. Data were collected through self-administered questionnaire, which includes but not limits to demographic data, personal behaviors and family history of cancer. Retrospective dose reconstruction was conducted to estimate the cumulative doses of the x-ray workers. Inferential statistics, t-test and 2 tests were used to compare the differences between each group. We used the logistic regression model to calculate the odds ratio (OR) and 95% confidence interval (CI) of cancer by adjusting the age, gender. All 34 breast cancer cases and 45 esophageal cancer cases that detected in a cohort conducted among health workers between 1950~2011 were included in this presented study, and 158 cancer-free controls were selected by frequency-matched (1:2). Our study found that the occupational radiation exposure was associated with a significantly increased cancer risk compared with the control, especially in breast cancer and esophageal cancer (adjusted OR=2.90, 95% CI: 1.19-7.04 for breast cancer; OR=4.19, 95% CI: 1.87-9.38 for esophageal cancer, and OR=3.43, 95% CI: 1.92-6.12 for total cancer, respectively). The occupational X-ray radiation exposure was associated with increasing cancer risk, which indicates that proper intervention and prevention strategies may be needed in order to bring down the occupational cancer risk.

진단용 X 선관 절연유의 전기적 특성 (Electrical Properties of Insulating Oils for Diagnostic X-ray Tube)

  • 김건중;이인성;백금문;김두호;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.597-600
    • /
    • 2001
  • In order to investigate the electrical properties of X-ray tube oils for insulating and cooling, the breakdown characteristics in temperature range of $20\sim100[^{\circ}C]$, that of AC breakdown in 0.5~2.5[mm] of gap length, we are made researches. The classification for the physical properties of oil for X-ray tube by FTIR and H-NMR experiments was confirmed to type of mineral oils. As for the dependance of breakdown characteristics due to electrode gap length, breakdown voltage was found nearly uniform by impurity effect according to the increase of gap. As a result the characteristics for AC breakdown, the dielectric strength was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range.

  • PDF

진단용 X 선관 절연유의 전기적 특성 (Electrical Properties of Insulating Oils for Diagnostic X-ray Tube)

  • 김건중;이인성;백금문;김두호;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In order to investigate the electrical properties of X-ray tube oils for insulating and cooling, the breakdown characteristics in temperature range of 20∼100[$^{\circ}C$], that of AC breakdown in 0.5∼2.5(mm) of gap length, we are made researches. The classification for the physical properties of oil for X-ray tube by FTIR and $^1$H-NMR experiments was confirmed to type of mineral oils. As for the dependance of breakdown characteristics due to electrode gap length, breakdown voltage was found nearly uniform by impurity effect according to the increase of gap. As a result the characteristics for AC breakdown, the dielectric strength was increased to 90[$^{\circ}C$] but decreased over 90[$^{\circ}C$] in the temperature range.

  • PDF