• Title/Summary/Keyword: diagnostic reference levels

Search Result 47, Processing Time 0.034 seconds

Double-Chambered Right Ventricle in an Old Standard Poodle Dog

  • Yunho Jeong;Yoonhwan Kim;Eunchan Lee;Ju-Hyun An;Sooyoung Choi;Jin-Young Chung;Jin-Ok Ahn
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.130-134
    • /
    • 2023
  • A 12-year-old Standard Poodle presented with intermittent weakness and occasional dyspnea at the Veterinary Medicine Teaching Hospital of Kangwon National University. A grade of 4 out of 6 systolic murmur with an irregular tachycardic rhythm was auscultated on both sides of the chest. Systolic blood pressure was 140 mmHg. Panting was noticed in the hospital, but there was no crackle sound. Blood analysis revealed mild increases in liver panel levels (alanine aminotransferase 149 [reference interval, 19-70] U/L; and alkaline phosphatase, 185 [reference interval, 15-127] U/L) and severe increases in cardiac biomarker levels (n-terminal pro-brain natriuretic peptide, 4169 [reference interval, 50-900] pmol/L; and cardiac troponin I, 0.22 [reference interval, 0.03-0.12] ng/mL). On electrocardiography, irregularly irregular supraventricular tachycardic rhythm with an f-wave and no distinct p-wave was observed. Generalized cardiomegaly with an enlarged right atrium and left ventricle was confirmed on thoracic radiography. Moreover, hepatomegaly and an enlarged caudal vena cava were observed. Echocardiographic evaluation revealed a fibromuscular diaphragm in the right ventricle. Because of the obstructive lesion in the right ventricle, the right atrium and ventricle were enlarged (right atrial area index, 38.82 cm2/m2 [reference interval, 4.2-10.2 cm2/m2]; right ventricle end-diastolic area index, 14.152 cm2/m2 [reference interval, 4.9-10.92 cm2/m2]). Accordingly, the patient was diagnosed with double-chambered right ventricle (DCRV). Pimobendan, furosemide, enalapril, diltiazem, and S-adenosylmethionine (SAMe) were prescribed, and all symptoms were relieved. DCRV is a right-sided congenital heart defect resembling pulmonic valve stenosis. If symptoms are not severe, medical therapy can be facilitated without surgery or the balloon dilation.

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea (우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량)

  • Lee, Kwang-Yong;Lee, Byung-Young;Lee, Jung-Eun;Lee, Hyun-Koo;Jung, Seung-Hwan;Kim, Byung-Woo;Kim, Hyeog-Ju;Kim, Dong-Sup
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.401-410
    • /
    • 2009
  • Purpose : Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. Methods : The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. Results : According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60~97 kVp, with the average use being 75 kVp, and the tube current ranged between 8~123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65~100 kVp (average use: 78 kVp) and 70~109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10~100 mAs(average use: 35 mAs) and between 8.9~300 mAs(average use: 64 mAs), respectively. The measurements of entrance surface dose that patients receive during the pelvis and lumbar spine radiography show the following results: in the posteroanterior view of pelvis radiography, the minimum value is 0.59 mGy, the maximum value is 12.69 mGy and the average value is 2.88 mGy with the 1st quartile value being 1.91 mGy, the median being 0.59 mGy, and the 3rd quartile value being 3.43 mGy. Also, in the posteroanterior view of lumbar spine radiography, the minimum value is 0.64 mGy, the maximum value is 23.84 mGy, and the average value is 3.68 mGy with the 1st quartile value being 2.41 mGy, the median being 3.40 mGy, and the 3rd quartile value being 4.08 mGy. In the lateral view of lumbar spine radiography, the minimum value is 1.90 mGy, the maximum value is 45.42 mGy, and the average value is 10.08 mGy with the 1st quartile value being 6.03 mGy, the median being 9.09 mGy and the 3rd quartile value being 12.65 mGy. Conclusions : The diagnostic reference levels for patient radiation dose to be recommended to the medical institutes in Korea is 3.42 mGy for the posteroanterior view of pelvis radiography, 4.08 mGy for the posteroanterior view of lumbar spine radiography, and 12.65 mGy for the lateral view of lumbar spine radiography. Such values are all lower than the values recommended by 6 international organizations including World Health Organization, where the recommended values are 10 mGy for the posteroanterior view of pelvis radiography, 10 mGy for the posteroanterior view of lumbar spine radiography and 30 mGy for the lateral view of lumbar spine radiography.

  • PDF

Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital (소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로)

  • Lee, Jae-Seung;Kim, Hyun-Jin;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.290-296
    • /
    • 2015
  • The purpose of this study was to derive the proposals and to suggest the exposure dose reduction scheme on pediatric head CT scan by analyzing and comparing CT dose index (CTDI) and the national diagnostic reference levels. From January 2014 to December, 231 children under 10years who were requested a pediatric head CT scan with head injury were examined. Research methods were to research and analyze the general characteristics kVp, mA test coverage $CTDI_{vol}$ and DLP referring to dose reports and electronic medical record (EMR). As a result, 7.4%(17 patients) of the total subjects in $CTDI_{vol}$ showed a national diagnostic reference levels exceeding. For DLP 41.6%(96 patients) in excess was relatively higher than $CTDI_{vol}$. DLP was exceeded more than about 60% that is higher than the CT dose index presented by Korea Food & Drug Administration. it is cause of high DLP that scan range increased more than about 30% wider than the standard test coverage presented in Health Insurance Review & Assessment Service. In conclusion, it is able to significantly lower the dose if it is complied with checking the baseline scan range of pediatric head CT scan and appropriately adjusting the protocol.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Extremely Increased Serum Carbohydrate Antigen 19-9 Levels Caused by New or Resistant Infections to Previous Antibiotics in Chronic Lung Diseases

  • Shin, Ji Young;Yoo, Su Jin;Park, Bo Mi;Jung, Sung Su;Kim, Ju Ock;Lee, Jeong Eun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.3
    • /
    • pp.125-127
    • /
    • 2013
  • In this paper, we describe 72-year-old female patient without evidence of malignant disease presented with significantly elevated serum carbohydrate antigen (CA) 19-9 levels by respiratory infections. She was diagnosed with respiratory infections due to Mycobacterium avium complex and Pseudomonas aeruginosa. The serum CA 19-9 levels remarkably increased (1,453-5,300 U/mL; reference range, <37 U/mL) by respiratory infection and abruptly decreased (357-534 U/mL) whenever infection was controlled by specific treatments. This case suggests that serum CA 19-9 levels may be used as a diagnostic marker to indicate new or resistant infections to previous antibiotics in chronic lung diseases without significant changes in chest X-ray findings.

MicroRNAs and periodontal disease: a qualitative systematic review of human studies

  • Mico-Martinez, Pablo;Alminana-Pastor, Pedro J.;Alpiste-Illueca, Francisco;Lopez-Roldan, Andres
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.6
    • /
    • pp.386-397
    • /
    • 2021
  • Purpose: MicroRNAs (miRNAs) are epigenetic post-transcriptional regulators that modulate gene expression and have been identified as biomarkers for several diseases, including cancer. This study aimed to systematically review the relationship between miRNAs and periodontal disease in humans, and to evaluate the potential of miRNAs as diagnostic and prognostic biomarkers of disease. Methods: The review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines (reference number CRD42020180683). The MEDLINE, Scopus, Cochrane Library, Embase, Web of Science, and SciELO databases were searched for clinical studies conducted in humans investigating periodontal diseases and miRNAs. Expression levels of miRNAs across the different groups were analysed using the collected data. Results: A total of 1,299 references were identified in the initial literature search, and 23 articles were finally included in the review. The study designs were heterogeneous, which prevented a meta-analysis of the data. Most of the studies compared miRNA expression levels between patients with periodontitis and healthy controls. The most widely researched miRNA in periodontal diseases was miR-146a. Most studies reported higher expression levels of miR-146a in patients with periodontitis than in healthy controls. In addition, many studies also focused on identifying target genes of the differentially expressed miRNAs that were significantly related to periodontal inflammation. Conclusions: The results of the studies that we analysed are promising, but diagnostic tests are needed to confirm the use of miRNAs as biomarkers to monitor and aid in the early diagnosis of periodontitis in clinical practice.

Human Epididymis Protein 4 Reference Intervals in a Multiethnic Asian Women Population

  • Mokhtar, N.M.;Thevarajah, M.;M.A., Noorazmi;M., Isahak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6391-6395
    • /
    • 2012
  • Background: Ovarian cancer is ranked as the fifth most common cause of cancer death in women. In Malaysia, it is the fourth most common cancer in females. CA125 has been the tumor marker of choice in ovarian cancer but its diagnostic specificity in early stages is only 50%. Hence, there is a critical need to identify an alternative tumor marker that is capable of detecting detect ovarian cancer at an early stage. HE4 is a new tumor marker proposed for the early diagnosis of ovarian cancer and disease recurrence. Currently, none of the normal ranges of HE4 quoted in the literature are based on data for a multiethnic Asian population. Therefore, the aim of this study was to determine reference intervals for HE4 in an Asian population presenting in University Malaya Medical Centre, a tertiary reference hospital. Materials and Methods: 300 healthy women were recruited comprising 150 premenopausal and 150 postmenopausal women, aged from 20-76 years. All women were subjected to a pelvic ultrasonograph and were confirmed to be free from ovarian pathology on recruitment. Serum HE4 levels were determined by chemiluminescent microparticle immunoassay (CMIA, Abbott Architect). The reference intervals were determined following CLSI guidelines (C28-A2) using a non-parametric method. Results: The upper limits of the $95^{th}$ percentile reference interval (90%CI) for all the women collectively were 64.6 pmol/L, and 58.4 pmol/L for premenopausal) and 69.0 pmol/L for postmenopausal. The concentration of HE4 was noted to increase with age especially in women who were more than 50 years old. We also noted that our proposed reference limit was lower compared to the level given by manufacturer Abbott Architect HE4 kit insert (58.4 vs 70 pmol/L for premenopausal group and 69.0 vs 140 pmol/L in the postmenopausal group). The study also showed a significant difference in HE4 concentrations between ethnic groups (Malays and Indians). The levels of HE4 in Indians appeared higher than in Malays (p<0.05), while no significant differences were noted between the Malays and Chinese ethnic groups. Conclusions: More data are needed to establish a reference interval that will better represent the multiethnic Malaysian population. Probably a larger sampling size of equal representation of the Malay, Chinese, Indians as well as the other native ethnic communities will give us a greater confidence on whether genetics plays a role in reference interval determination.

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.