Huh Seung Jae;Ahn Yong Chan;Lim Do Hoon;Cho Chung Keun;Kim Dae Yong;Yeo Inhwan;Kim Moon Kyung;Chang Seung Hee;Park Suk Won
Radiation Oncology Journal
/
v.18
no.1
/
pp.67-72
/
2000
Background :The authors have developed a Digital image chart(DIC) and digital Radiotherapy Record System (DRRS). We have evaluated the DIC and DRRS for reliability, usefulness, ease of use, and efficiency. Materials and Methods :The basic design of the DIC and DRRS was to build an digital image database of radiation therapy Patient records for a more efficient and timely flow of critical image information throughout the department. This system is a submit of comprehensive radiation oncology management system (C-ROMS) and composed of a picture archiving and communication system (PACS), a radiotherapy information database, and a radiotherapy imaging database. The DIC and DRRS were programmed using Delphi under a Windows 95 environment and is capable of displaying the digital images of patients identification photos, simulation films, radiotherapy setup, diagnostic radiology images, gross lesion Photos, and radiotherapy Planning isodose charts with beam arrangements. Twenty-three clients in the department are connected by Ethernet (10 Mbps) to the central image server (Sun Ultra-sparc 1 workstation). Results :From the introduction of this system in February 1998 through December 1999, we have accumulated a total of 15,732 individual images for 2,556 patients. We can organize radiation therapy in a 'paperless' environment in 120 patients with breast cancer. Using this system, we have succeeded in the prompt, accurate, and simultaneous access to patient care information from multiple locations throughout the department. This coordination has resulted in improved operational efficiency within the department. Conclusion :The authors believe that the DIC and DRRS has contributed to the improvement of radiation oncology department efficacy as well as to time and resource savings by providing necessary visual information throughout the department conveniently and simultaneously. As a result, we can also achieve the 'paperless' and 'filmless' practice of radiation oncology with this system.
Kang Byoung-Chul;Ha Il-Soo;Kim In-One;Cheong Hae-Il;Choi Yong;Ko Kwang-Wook
Childhood Kidney Diseases
/
v.1
no.2
/
pp.101-108
/
1997
Purpose : The clinical characteristics of renovascular hypertension (RVHT) in children were analyzed. Methods : Medical records of 16 children diagnosed as RVHT on the basis of angiography during Jan. '86 to Jun. 94 in our hospital were reviewed retrospectively. Results : The mean age at the onset was 8.5 yrs and the sex ratio(M:F) was 7:9. The causes of RVHT were Takayasu arteritis in 6, Moyamoya disease in 5, and fibromuscular dysplasia in 3 patients. Abdominal bruit was noted in 6 patients (38%). Peripheral renin activity was raised in all tested patients. Bilateral renal arterial involvemnent was found in 9 patients (56%). Captopril renal scans showed good correlation with angiographic findings. Five patients were treated with antihypertensives only, and blood pressure was controlled completely in 2 and incompletely in 3. Percutaneous transluminal angioplasty was performed in 10 patients with 50% of success rate. However, hypertension was recurred due to restenosis or accompaning aortic stenosis in 3 patients. Surgical treatment was performed in 4 patients, and the blood pressure was controlled partially in 1 and poorly in the remaining 3. Conclusions : Takayasu arteritis, Moyamoya disease and fibromuscular dysplasia are the major causes of childhood RVHT in our country. The diagnosis of RVHT in children should be based on a set of tests individually selected for case by case. For the low curability of the current treatment modalities available, RVHT in children should not be regarded as 'curable' so far. We expect, however, that the outcome will be improved by more extensive application of the newly developed surgical technique.
Purpose : The purpose of this study was to find out useful radiological projection of shoulder subluxation in patients with post-stroke hemiplegia. Methods : A total of 33 patients with post-stroke hemiplegia were included(20 men and 13 women, mean age 62.3 years) and having the subluxed shoulder over one finger breath. The shoulder subluxation was determined as the ratio of the radiographic vertical and horizontal distance. The vertical distance was determined by measuring the distance between the most inferolateral point of the acromion and the central point of the humeral head. The horizontal distance was determined by measuring the distance between the central point of the glenoid fossa and the central point of the humeral head. To measure of the shoulder subluxation, the shoulder AP, axial and transthoracic lateral projections were taken on both affected and unaffected shoulders. We analyzed the difference of subluxation distance by t-test. Results : When patients was in sitting position, the average time of being shoulder subluxation was 123 second. There was significant difference between supine($49.90{\pm}13.6\;mm$) and sitting position($60.72{\pm}16.3\;mm$) in the vertical distance of shoulder anterior-posterior projection. Also, there was significant difference on transthoracic lateral projections, Affected $35.92{\pm}6.2\;mm$, Unaffected $28.76{\pm}5.4\;mm$. But in case of shoulder axial projection(supine position), there was no significant difference (Unaffected and affected was $23.01{\pm}9.0\;mm$, $22.45{\pm}8.2\;mm$ each). Conclusion : Radiological projection of shoulder subluxation has diagnostic value when it goes after check out the process of subluxation through finger breadth test. For this, patients must be in sitting and shoulder neutral position about 2 minutes. In addition, Shoulder anterior-posterior and transthoracic projection were significant to diagnose subluxation. But in axial projection, there wasn't meaningful differences.
The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.
Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.
Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.
Purpose: The aims of this study were to find brain regions in which gray matter volume was reduced and to show the capability of voxel-based morphometry (VBM) analysis for lateralizing epileptogenic zones in medial temporal lobe epilepsy (mTLE). The findings were compared with fluorodeoxyglucose positron omission tomography (FDG PET). Materials and Methods: MR T1-weighted images of 12 left mTLE and 11 right mTLE patients were compared with those of 37 normal controls. Images were transformed to standard MNI space and averaged in order to create study-specific brain template. Each image was normalized to this local template and brain tissues were segmented. Modulation VBM analysis was performed in order to observe gray matter volume change. Gray matter was smoothed with a Gaussian kernel. After these preprocessing, statistical analysis was peformed using statistical parametric mapping software (SPM99). FDG PET images were compared with those of 22 normal controls using SPM. Results: Gray matter volume was significantly reduced in the left amygdala and hippocampus in left mTLE. In addition, volume of cerebellum, anterior cingulate, and fusiform gyrus in both sides and left insula was reduced. In right mTLE, volume was reduced significantly in right hippocampus. In contrast, FDG uptake was decreased in broad areas of left or right temporal lobes in left TLE and right TLE, respectively. Conclusions: Gray matter loss was found in the ipsilateral hippocampus by modulation VBM analysis in medial temporal lobe epilepsy. This VBM analysis might be useful in lateralizing the epileptogenic zones in medial temporal lobe epilepsy, while SPM analysis of FDG PET disclosed hypometabolic epileptogenic zones.
Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.
Journal of the Korea Academia-Industrial cooperation Society
/
v.14
no.6
/
pp.2958-2965
/
2013
Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.
Purpose: The ultrasonography (USG) and computed tomography (CT) are popular diagnostic tools for the diagnosis of acute appendicitis in children, but there are many debates about their clinical significance. The purpose of this study is to clarify the clinical significance of USG, CT and follow-up CT performed subsequently to USG, especially in perforated acute appendicitis in children. Methods: We have reviewed 419 cases of surgically confirmed acute appendicitis in children under the age of sixteen, who had been treated in Inje University Ilsan Paik Hospital from March 2002 to February 2006. All the clinical data including the results of USG and CT were collected and analyzed. Results: Sensitivity, specificity, positive and negative predictive values of USG were 98.7%, 96.8%, 98.1%, 97.8% in non-perforation group and 90.8%, 100%, 100%, 81.9% in perforation group. Those of CT were 96.4%, 100%, 100%, 96.5% and 86.6%, 100%, 100%, 87.5% respectively. Those of follow-up CT after USG were 100%, 100%, 100%, 100% and 87.5%, 100%, 100%, 92.0% respectively. The duration of using antibiotics in seven patients showed positive correlation with the interval between two imaging studies (r=0.0472, p=0.019). There was no statistical significance of correlation when these imaging studies performed within 30 hours together. Conclusion: In most of the cases, single choice between USG and CT would be enough to diagnose the acute appendicitis in children. But, it may be helpful to perform CT as early as possible subsequently to USG when there is discrepancy between initial USG and clinical impression.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.