• Title/Summary/Keyword: diagnostic radiology

Search Result 2,280, Processing Time 0.026 seconds

Radiation Oncology Digital Image Chart 8nd Digital Radiotherapv Record System at Samsung Medical Center (디지털 화상 병력 시스템과 디지털 방사선치료 기록 시스템의 개발과 사용 경험)

  • Huh Seung Jae;Ahn Yong Chan;Lim Do Hoon;Cho Chung Keun;Kim Dae Yong;Yeo Inhwan;Kim Moon Kyung;Chang Seung Hee;Park Suk Won
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2000
  • Background :The authors have developed a Digital image chart(DIC) and digital Radiotherapy Record System (DRRS). We have evaluated the DIC and DRRS for reliability, usefulness, ease of use, and efficiency. Materials and Methods :The basic design of the DIC and DRRS was to build an digital image database of radiation therapy Patient records for a more efficient and timely flow of critical image information throughout the department. This system is a submit of comprehensive radiation oncology management system (C-ROMS) and composed of a picture archiving and communication system (PACS), a radiotherapy information database, and a radiotherapy imaging database. The DIC and DRRS were programmed using Delphi under a Windows 95 environment and is capable of displaying the digital images of patients identification photos, simulation films, radiotherapy setup, diagnostic radiology images, gross lesion Photos, and radiotherapy Planning isodose charts with beam arrangements. Twenty-three clients in the department are connected by Ethernet (10 Mbps) to the central image server (Sun Ultra-sparc 1 workstation). Results :From the introduction of this system in February 1998 through December 1999, we have accumulated a total of 15,732 individual images for 2,556 patients. We can organize radiation therapy in a 'paperless' environment in 120 patients with breast cancer. Using this system, we have succeeded in the prompt, accurate, and simultaneous access to patient care information from multiple locations throughout the department. This coordination has resulted in improved operational efficiency within the department. Conclusion :The authors believe that the DIC and DRRS has contributed to the improvement of radiation oncology department efficacy as well as to time and resource savings by providing necessary visual information throughout the department conveniently and simultaneously. As a result, we can also achieve the 'paperless' and 'filmless' practice of radiation oncology with this system.

  • PDF

Renovascular Hypertension in Children (소아의 신혈관성 고혈압)

  • Kang Byoung-Chul;Ha Il-Soo;Kim In-One;Cheong Hae-Il;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.101-108
    • /
    • 1997
  • Purpose : The clinical characteristics of renovascular hypertension (RVHT) in children were analyzed. Methods : Medical records of 16 children diagnosed as RVHT on the basis of angiography during Jan. '86 to Jun. 94 in our hospital were reviewed retrospectively. Results : The mean age at the onset was 8.5 yrs and the sex ratio(M:F) was 7:9. The causes of RVHT were Takayasu arteritis in 6, Moyamoya disease in 5, and fibromuscular dysplasia in 3 patients. Abdominal bruit was noted in 6 patients (38%). Peripheral renin activity was raised in all tested patients. Bilateral renal arterial involvemnent was found in 9 patients (56%). Captopril renal scans showed good correlation with angiographic findings. Five patients were treated with antihypertensives only, and blood pressure was controlled completely in 2 and incompletely in 3. Percutaneous transluminal angioplasty was performed in 10 patients with 50% of success rate. However, hypertension was recurred due to restenosis or accompaning aortic stenosis in 3 patients. Surgical treatment was performed in 4 patients, and the blood pressure was controlled partially in 1 and poorly in the remaining 3. Conclusions : Takayasu arteritis, Moyamoya disease and fibromuscular dysplasia are the major causes of childhood RVHT in our country. The diagnosis of RVHT in children should be based on a set of tests individually selected for case by case. For the low curability of the current treatment modalities available, RVHT in children should not be regarded as 'curable' so far. We expect, however, that the outcome will be improved by more extensive application of the newly developed surgical technique.

  • PDF

Radiological Projection for Diagnosis of Shoulder Subluxation in Patients with Post-Stroke Hemiplegia (편마비 환자에서의 견관절 아탈구 진단에 유용한 촬영법)

  • Cho, Kwang-Ho;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.253-259
    • /
    • 2009
  • Purpose : The purpose of this study was to find out useful radiological projection of shoulder subluxation in patients with post-stroke hemiplegia. Methods : A total of 33 patients with post-stroke hemiplegia were included(20 men and 13 women, mean age 62.3 years) and having the subluxed shoulder over one finger breath. The shoulder subluxation was determined as the ratio of the radiographic vertical and horizontal distance. The vertical distance was determined by measuring the distance between the most inferolateral point of the acromion and the central point of the humeral head. The horizontal distance was determined by measuring the distance between the central point of the glenoid fossa and the central point of the humeral head. To measure of the shoulder subluxation, the shoulder AP, axial and transthoracic lateral projections were taken on both affected and unaffected shoulders. We analyzed the difference of subluxation distance by t-test. Results : When patients was in sitting position, the average time of being shoulder subluxation was 123 second. There was significant difference between supine($49.90{\pm}13.6\;mm$) and sitting position($60.72{\pm}16.3\;mm$) in the vertical distance of shoulder anterior-posterior projection. Also, there was significant difference on transthoracic lateral projections, Affected $35.92{\pm}6.2\;mm$, Unaffected $28.76{\pm}5.4\;mm$. But in case of shoulder axial projection(supine position), there was no significant difference (Unaffected and affected was $23.01{\pm}9.0\;mm$, $22.45{\pm}8.2\;mm$ each). Conclusion : Radiological projection of shoulder subluxation has diagnostic value when it goes after check out the process of subluxation through finger breadth test. For this, patients must be in sitting and shoulder neutral position about 2 minutes. In addition, Shoulder anterior-posterior and transthoracic projection were significant to diagnose subluxation. But in axial projection, there wasn't meaningful differences.

  • PDF

Study on Measurements of the Mandible BMD According to the ROI Variation (관심영역 변화에 따른 하악골 골밀도 측정에 대한 연구)

  • Tak, Jeong-Nam
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

T1-201 Per Rectum Scintigraphy in Chronic Liver Disease: Assessment of T1-201 Uptake Indices (만성 간질환에서의 T1-201 경직장 문맥 신티그라피: T1-201 섭취 지표의 평가)

  • Moon, Won-Jin;Choi, Yun-Young;Cho, Suk-Shin;Lee, Min-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.49-56
    • /
    • 1999
  • Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.

  • PDF

Voxel-based Morphometry (VBM) Based Assessment of Gray Matter Loss in Medial Temporal Lobe Epilepsy: Comparison with FDG PET (화소기반 형태분석 방법을 이용한 내측측두엽 간질환자의 회백질 부피/농도 감소평가; FDG PET과의 비교)

  • Kang, Hye-Jin;Lee, Ho-Young;Lee, Jae-Sung;Kang, Eun-Joo;Lee, Sang-Gun;Chang, Kee-Hyun;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.30-40
    • /
    • 2004
  • Purpose: The aims of this study were to find brain regions in which gray matter volume was reduced and to show the capability of voxel-based morphometry (VBM) analysis for lateralizing epileptogenic zones in medial temporal lobe epilepsy (mTLE). The findings were compared with fluorodeoxyglucose positron omission tomography (FDG PET). Materials and Methods: MR T1-weighted images of 12 left mTLE and 11 right mTLE patients were compared with those of 37 normal controls. Images were transformed to standard MNI space and averaged in order to create study-specific brain template. Each image was normalized to this local template and brain tissues were segmented. Modulation VBM analysis was performed in order to observe gray matter volume change. Gray matter was smoothed with a Gaussian kernel. After these preprocessing, statistical analysis was peformed using statistical parametric mapping software (SPM99). FDG PET images were compared with those of 22 normal controls using SPM. Results: Gray matter volume was significantly reduced in the left amygdala and hippocampus in left mTLE. In addition, volume of cerebellum, anterior cingulate, and fusiform gyrus in both sides and left insula was reduced. In right mTLE, volume was reduced significantly in right hippocampus. In contrast, FDG uptake was decreased in broad areas of left or right temporal lobes in left TLE and right TLE, respectively. Conclusions: Gray matter loss was found in the ipsilateral hippocampus by modulation VBM analysis in medial temporal lobe epilepsy. This VBM analysis might be useful in lateralizing the epileptogenic zones in medial temporal lobe epilepsy, while SPM analysis of FDG PET disclosed hypometabolic epileptogenic zones.

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

Clinical Significance of Follow-up CT after Ultrasonography for Acute Appendicitis in Children (소아 급성 충수염에서 복부초음파 이후 전산화단층촬영 추적 검사의 임상적 의의)

  • Yu, Seong-Keun;Moon, Jin-Soo;Kim, Nam-Hee;Hwang, Jong-Hee;Nam, Seung-Yeon;Kim, Dong-Wook;Lee, Chong-Guk;Seo, Jung-Wook;Heo, Tae-Gil
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: The ultrasonography (USG) and computed tomography (CT) are popular diagnostic tools for the diagnosis of acute appendicitis in children, but there are many debates about their clinical significance. The purpose of this study is to clarify the clinical significance of USG, CT and follow-up CT performed subsequently to USG, especially in perforated acute appendicitis in children. Methods: We have reviewed 419 cases of surgically confirmed acute appendicitis in children under the age of sixteen, who had been treated in Inje University Ilsan Paik Hospital from March 2002 to February 2006. All the clinical data including the results of USG and CT were collected and analyzed. Results: Sensitivity, specificity, positive and negative predictive values of USG were 98.7%, 96.8%, 98.1%, 97.8% in non-perforation group and 90.8%, 100%, 100%, 81.9% in perforation group. Those of CT were 96.4%, 100%, 100%, 96.5% and 86.6%, 100%, 100%, 87.5% respectively. Those of follow-up CT after USG were 100%, 100%, 100%, 100% and 87.5%, 100%, 100%, 92.0% respectively. The duration of using antibiotics in seven patients showed positive correlation with the interval between two imaging studies (r=0.0472, p=0.019). There was no statistical significance of correlation when these imaging studies performed within 30 hours together. Conclusion: In most of the cases, single choice between USG and CT would be enough to diagnose the acute appendicitis in children. But, it may be helpful to perform CT as early as possible subsequently to USG when there is discrepancy between initial USG and clinical impression.

  • PDF