T1-201 Per Rectum Scintigraphy in Chronic Liver Disease: Assessment of T1-201 Uptake Indices

만성 간질환에서의 T1-201 경직장 문맥 신티그라피: T1-201 섭취 지표의 평가

  • Moon, Won-Jin (Departments of Diagnostic Radiology, Hanyang University College of Medicine) ;
  • Choi, Yun-Young (Departments of Nuclear Medicine, Hanyang University College of Medicine) ;
  • Cho, Suk-Shin (Departments of Nuclear Medicine, Hanyang University College of Medicine) ;
  • Lee, Min-Ho (Departments of Internal Medicine, Hanyang University College of Medicine)
  • 문원진 (한양대학교 의과대학 진단방사선과학교실) ;
  • 최윤영 (한양대학교 의과대학 핵의학과학교실) ;
  • 조석신 (한양대학교 의과대학 핵의학과학교실) ;
  • 이민호 (한양대학교 의과대학 내과학교실)
  • Published : 1999.02.27

Abstract

Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.

목적: T1-201 경직장 문맥신티그라피에서 심장/간 섭취비(단락지수)는 만성 간질환 환자에서 문맥-체단락을 평가하는 데 유용한 지표로 알려져 있다. 본 연구는 만성 활동성 간염과 간경변 환자에서 T1-201 섭취 양상과 초기 간/심장 섭취속도의 유용성을 평가하고, 단락지수와의 연관성을 알아보고자 하였다. 대상 및 방법: 간생검으로 만성 간질환(만성 활동성 간염 35명, 간경화 23명)을 진단받은 58명의 환자에서 T1-201 18.5 MBq를 상부직장에 주입 후 T1-201 경직장 문맥신티그라피를 시행하였다. 간섭취 양상(1형: 균일 분포, 2형: 분절단위 불균일 분포, 3형: 비분절단위 불균일 분포)과 비장, 심장, 신장의 간외 분포양상(grade 0: 방사능 섭취 없음, grade 1: 간보다 적은 방사능 정도, grade 2: 간과 비슷한 방사능 정도, grade 3: 간보다 많은 방사능 정도), 초기 간/심장 섭취속도(처음 10분간의 간/심장 섭취비의 기울기)와 단락지수(심장/간 계수비)를 구하였다. T1-201 섭취 양상과 초기 간/심장 섭취비를 병리진단, 단락지수와 비교하였다. 결과: 간 섭취 양상은 만성 활동성 간염에서 1형과 2형의 간내 방사능 분포 양상이 많았고(만성 활동성 간염: 27/35, 간경변: 8/23), 간경변은 3형이 유의하게 많았다(만성활동성 간염. 8/35, 간경변: 15/23)(p<0.005). 간외분포양상의 grade는 간경변에서 유의하게 높았다(비장: p<0.001, 기타 연 조직 p<0.005). 초기 간/심장섭취속도는 만성 활동성 간염($0.110{\pm}$0.111)이 간경변($0.014{\pm}0.090$)보다 유의하게 높았으며(p<0.001), 간경변의 판정지표로서 0.05를 기준으로 하였을 때 예민도와 특이도는 각각 77.2%, 67.7%였다. 초기간/심장 섭취속도와 단락지수는 음의 상관관계를 보였다(r=-0.3347, p<0.01). 결론: T1-201 경직장 문맥 신티그라피에서 간 및 간외 방사능 분포와 초기 간/심장 섭취속도는 만성 간질환 환자에서 문맥-체단락을 평가하는 데 유용한 지표로 생각된다.