• Title/Summary/Keyword: diagnostic quality

Search Result 816, Processing Time 0.026 seconds

- Development of Digital Fluoroscopic Image Recording System for Customer Safety - (고객 안전을 위한 디지털 방사선장치(DRF)의 투시영상기록장치 개발)

  • Rhim Jae Dong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Many system devices for fluoroscopic and general X-ray studies in diagnostic radiographic system have been being changed from analog mode to digital mode. In addition, among diagnostic imaging and radiologic examinations, fluoroscopic studies that requires functional diagnosis is being widely used. The video recording method of fluoroscopic studies has been useful in functional image diagnosis and dynamic image observation, but the utility of its image quality is being reduced because of limitation in setting play segments of the video player, inconvenience of play, difficulties in preserving reproduced images, the change of image quality, etc. In order to complement these shortages, it is necessary to facilitate access to patient diagnosis information such as storing, editing and sharing functional diagnosis images in response to the trend of the digitalization of digital radiographic & fluoroscopic system(DRF). Thus this study designed and implemented a device of storing functional dynamic images real time using a computer rather than existing video recording, aiming at contribution to functional image diagnosis.

Development of Healthcare Data Quality Control Algorithm Using Interactive Decision Tree: Focusing on Hypertension in Diabetes Mellitus Patients (대화식 의사결정나무를 이용한 보건의료 데이터 질 관리 알고리즘 개발: 당뇨환자의 고혈압 동반을 중심으로)

  • Hwang, Kyu-Yeon;Lee, Eun-Sook;Kim, Go-Won;Hong, Seong-Ok;Park, Jung-Sun;Kwak, Mi-Sook;Lee, Ye-Jin;Lim, Chae-Hyeok;Park, Tae-Hyun;Park, Jong-Ho;Kang, Sung-Hong
    • The Korean Journal of Health Service Management
    • /
    • v.10 no.3
    • /
    • pp.63-74
    • /
    • 2016
  • Objectives : There is a need to develop a data quality management algorithm to improve the quality of healthcare data using a data quality management system. In this study, we developed a data quality control algorithms associated with diseases related to hypertension in patients with diabetes mellitus. Methods : To make a data quality algorithm, we extracted the 2011 and 2012 discharge damage survey data from diabetes mellitus patients. Derived variables were created using the primary diagnosis, diagnostic unit, primary surgery and treatment, minor surgery and treatment items. Results : Significant factors in diabetes mellitus patients with hypertension were sex, age, ischemic heart disease, and diagnostic ultrasound of the heart. Depending on the decision tree results, we found four groups with extreme values for diabetes accompanying hypertension patients. Conclusions : There is a need to check the actual data contained in the Outlier (extreme value) groups to improve the quality of the data.

Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor (자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석)

  • Park, Sung-Tae;Yoon, Chong-Hyun;Park, Kwang-Bo;Auh, Yong-Ho;Lee, Hyoung-Jin;In, Kyung-Hwan;Kim, Keon-Chung
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis

  • Min Jung Ko;Dong A Park;Sung Hyun Kim;Eun Sook Ko;Kyung Hwan Shin;Woosung Lim;Beom Seok Kwak;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1240-1252
    • /
    • 2021
  • Objective: To compare the accuracy for detecting breast cancer in the diagnostic setting between the use of digital breast tomosynthesis (DBT), defined as DBT alone or combined DBT and digital mammography (DM), and the use of DM alone through a systematic review and meta-analysis. Materials and Methods: Ovid-MEDLINE, Ovid-Embase, Cochrane Library and five Korean local databases were searched for articles published until March 25, 2020. We selected studies that reported diagnostic accuracy in women who were recalled after screening or symptomatic. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A bivariate random effects model was used to estimate pooled sensitivity and specificity. We compared the diagnostic accuracy between DBT and DM alone using meta-regression and subgroup analyses by modality of intervention, country, existence of calcifications, breast density, Breast Imaging Reporting and Data System category threshold, study design, protocol for participant sampling, sample size, reason for diagnostic examination, and number of readers who interpreted the studies. Results: Twenty studies (n = 44513) that compared DBT and DM alone were included. The pooled sensitivity and specificity were 0.90 (95% confidence interval [CI] 0.86-0.93) and 0.90 (95% CI 0.84-0.94), respectively, for DBT, which were higher than 0.76 (95% CI 0.68-0.83) and 0.83 (95% CI 0.73-0.89), respectively, for DM alone (p < 0.001). The area under the summary receiver operating characteristics curve was 0.95 (95% CI 0.93-0.97) for DBT and 0.86 (95% CI 0.82-0.88) for DM alone. The higher sensitivity and specificity of DBT than DM alone were consistently noted in most subgroup and meta-regression analyses. Conclusion: Use of DBT was more accurate than DM alone for the diagnosis of breast cancer. Women with clinical symptoms or abnormal screening findings could be more effectively evaluated for breast cancer using DBT, which has a superior diagnostic performance compared to DM alone.

Systematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children (아동에서의 적외선 체온 측정의 진단정확도 연구 : 체계적 문헌 고찰과 메타분석)

  • Park, Young Joo;Park, Seong-Hi;Kang, Chang-Bum
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.6
    • /
    • pp.746-759
    • /
    • 2013
  • Purpose: Infrared thermometers are increasingly used as a convenient, non-invasive assessment method for febrile children. However, the diagnostic accuracy of the infrared thermometer for children has been questioned, particularly in relation to sensitivity and specificity. The aim of this study was to evaluate diagnostic accuracy of infrared thermometers in febrile children. Methods: Articles published between 1966 and 2012 from periodicals indexed in the Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected, using the following keywords: 'infrared thermometer'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Nineteen diagnostic studies with high methodological quality, involving 4,304 children, were included. The results of meta-analysis showed that the pooled sensitivity, specificity and AUC (Area Under the Curve) of infrared tympanic thermometers in children over 1 year were 0.80 (95% CI 0.78, 0.81), 0.94 (95% CI 0.93, 0.95) and 0.95 respectively. However the diagnostic accuracy of infrared tympanic thermometers in children with hyperthermia was low. Conclusion: The diagnostic accuracy of infrared tympanic thermometer was similar to axillary and rectal thermometers indicating a need for further research to substantiate these findings in children with hyperthermia.

A Study on the Clinical Application of Intelligent Replenishment System of Automatic X-ray Film Processor Based on Film Density (자동현상 지능화 보충방식의 임상적응에 관한 연구)

  • Lee, W.H.;Suh, S.S.;In, K.H.;Lee, H.J.;Kim, K.C.;Yoon, C.H.;Auh, Y.H.
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.49-53
    • /
    • 1999
  • To inquire its usefulness of the clinical application of intelligent replenishment system of automatic X-ray film processor based on film density, we processed the serial 300 sheets of radiographic film of chest [$14{\times}14"$, HR-C type] and bone [elbow & ankle($8{\times}10"$), skull($10{\times}12"$), hand & foot($11{\times}14"$), pelvis($14{\times}17"$), HR-G type, 68, 70, 77, 85 sheets respectively]. We analyzed the characteristic corves, relative speeds, average gradients and base plus fog densities every twenty five sheets. We also evaluated the developer and fixer replenishment volumes every that time. In the chest and bone radiograph two all, the characteristic curves were little change, and the relative speeds, average gradients and base plus fog densities were within the maximum control limits. The average developer replenishment volumes were about 43m1/sheet and 39m1/sheet respectively. It brings decreased results about 29% in comparison with the conventional replenishment system. In our experiences, we conclude that the intelligent replenishment system of automatic X-ray film processor based on film density maintains image quality consistently, decreases also the replenishment volumes. Therefore, this system will be resulted in economic and environmental effects, and solve problems of over and low replenishment volume.

  • PDF

Bacterial contaminants in extended boar semen and selection of effective antimicrobials (돼지 희석정액의 세균오염도 및 유효 항생제 선발)

  • Kim, Ha-Young;Byun, Jae-Won;Shin, Dong-Ho;Kim, Hyoung-Soon;Yoon, Hachung;Park, Choi-Kyu;Lee, O-Soo;Jung, Byeong Yeal
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • Bacterial contamination is an unavoidable finding of the semen collection process in boar and can lead in deleterious effects on semen quality and longevity if left uncontrolled. The purpose of this study is to identify the bacteria in extended boar semen and to select the effective antimicrobials to control of the contaminants. Of 116 extended boar semen samples submitted from eight AI centers in Korea, 39 (33.6%) samples were positive for bacterial contamination. Among 39 contaminated semen, most of them (84.6%) were contaminated with one or two bacterial species and there was no significant difference between two age groups $(\leq\;24\;and\;>\;24\;month\;old).$ Stenotrophomonas maltophilia (n = 18) was the most predominant bacterium followed by Elizabethkingia meningoseptica (n = 12), Sphingomonas paucimobilis (n = 12), Myroides spp. (n = 5), Ochrobactrum anthropi (n = 3), and so on. Enrofloxacin (72.9%), florfenicol (72.9%), bacitracin (49.2%) and tylosin (49.2%) showed higher sensitivity compared with penicillin (13.6%) or aminoglycosides (6.8%-18.6%). Brucella spp., Leptospira spp., Mycoplasma hyopneumoniae, Mycoplasma hyorhinis, Mycobacterium tuberculosis complex were not detected in semen by PCR.

Diagnostic Accuracy of Clinical Test for Anterior Cruciate Ligament Injury: Systematic Review

  • Deniz Yasemin;Sang-Woo Pyun;HyungSu Lee;Seong-Eun Kim;SunGyu Han;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Seong-gil Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.3
    • /
    • pp.57-63
    • /
    • 2023
  • Purpose: The aim of this study was to conduct a systematic review of randomized controlled studies from 2012 to present that explore the diagnostic accuracy of clinical tests used for diagnosing anterior cruciate ligament (ACL) injury. Methods: Study design: Systematic review. Literature search of the PubMed and Scholar databases was conducted using keywords related to diagnostic accuracy of clinical tests for ACL injury. The PRISMA Guidelines were followed to conduct this study. The Cochrane Risk of Bias Tool was utilized to assess the quality of each included study. Results: As a result, 8 studies were included, and 6 clinical tests used in ACL tears were evaluated for diagnostic accuracy. The pivot shift test was reported as having the highest +LR (29.5) value with a sensitivity of 59% and a specificity of 98%. However, the test with the lowest -LR value was the lever test, and the values were as follows: -LR (0.08), +LR (4.7), specificity (80%), sensitivity (94%). Conclusion: In this study, it was concluded that a single clinical test is not sufficient to determine the presence of ACL injury. Test combinations have a higher diagnostic accuracy than a single test. In this study, the accuracy of the clinical tests was examined without considering the amount of ACL rupture and acute-chronic condition. Further research is required to examine the impact of these two factors on diagnostic accuracy of clinical test.

Comparison of Clinical and Psychological Characteristics between Self-Reported Bruxism and Clinically Detected Bruxism by Wear Facet on Splint

  • Shim, Young-Joo;Kang, Jin-Kyu;Lee, You-Mee;Lim, Hyun-Dae
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • Purpose: Bruxism is commonly considered a major risk factor for temporomandibular disorders (TMD), and the psychosocial factors had been one of the etiologic factor of bruxism. But there are still unsolved issues on the relationship between sleep bruxism and TMD and the etiologic factors of bruxism. This study is aim to evaluate the clinical and psychosocial characteristics according to diagnostic grade of bruxism in TMD patients. Methods: Three hundred subjects were enrolled who were under the stabilization splint therapy for TMD. Recently international consensus proposed a diagnostic grading system of "possible", "probable", and "definite" sleep or awake bruxism for clinical and research purpose. According to their suggestion, we classified these subjects as self-reported bruxism (SRB) and wear facet bruxism (WFB). We investigated the clinical characteristics (sex, age, chief complaint, pain duration, visual analogue scale), sum of tenderness (temporomandibular joint, masticatory muscles, cervical muscles), diagnosis of TMD according to research diagnostic criteria (the Research Diagnostic Criteria for Temporomandibular Disorders, RDC/TMD), headache, subjective sleep quality (Pittsburgh Sleep Quality Index, PSQI), and psychosocial characteristics (Symptom Checklist-90-Revised, SCL-90-R) in enrolled subjects. We compared the clinical and psychosocial characteristics between these bruxism groups. Results: There were no significant correlation between self-reported and WFB (p=0.13). SRB subjects more reported pain as a chief complain than subject who did not report bruxism (p=0.014). The mean score of global PSQI was significantly higher in SRB than in did not report positively subjects (p=0.045). The mean score of anxiety and phobic anxiety was significantly higher in SRB than in did not reported positively subjects (p=0.045, p=0.041). Conclusions: Although bruxism is regarded as risk factor of TMD, this study showed inconsistent result between SRB and clinically detected bruxism by wear facet on slpint. We suggest that the clinician should consider with extreme caution when they assess SRB.

Characteristics of Insulation Failure in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연파괴 특성)

  • Kim, Hee-Dong;Kim, Kyeong-Yeol;Park, Deok-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.124-124
    • /
    • 2010
  • Diagnostic tests were performed on six high voltage motors. These tests included ac current, dissipation factor(tan6) and partial discharge(PD) magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 and No.2 motors(4.16 kV) failed near rated voltage of 12.3 kV and 14.2 kV, respectively. The breakdown voltage of No.3 and No.4 motors(6.6 kV) was 17.6 kV and 17.8 kV, respectively. These motors are higher that expected for good quality coils in 6.6 kV class motors.