Browse > Article
http://dx.doi.org/10.4040/jkan.2013.43.6.746

Systematic Review and Meta-Analyses of Diagnostic Accuracy of Infrared Thermometer when Identifying Fever in Children  

Park, Young Joo (College of Nursing, Korea University)
Park, Seong-Hi (School of Nursing, Pai Chai University)
Kang, Chang-Bum (Research Development Team, Korea Health Promotion Foundation)
Publication Information
Journal of Korean Academy of Nursing / v.43, no.6, 2013 , pp. 746-759 More about this Journal
Abstract
Purpose: Infrared thermometers are increasingly used as a convenient, non-invasive assessment method for febrile children. However, the diagnostic accuracy of the infrared thermometer for children has been questioned, particularly in relation to sensitivity and specificity. The aim of this study was to evaluate diagnostic accuracy of infrared thermometers in febrile children. Methods: Articles published between 1966 and 2012 from periodicals indexed in the Ovid Medline, Embase, CINAHL, Cochrane, KoreaMed, NDSL, KERIS and other databases were selected, using the following keywords: 'infrared thermometer'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Nineteen diagnostic studies with high methodological quality, involving 4,304 children, were included. The results of meta-analysis showed that the pooled sensitivity, specificity and AUC (Area Under the Curve) of infrared tympanic thermometers in children over 1 year were 0.80 (95% CI 0.78, 0.81), 0.94 (95% CI 0.93, 0.95) and 0.95 respectively. However the diagnostic accuracy of infrared tympanic thermometers in children with hyperthermia was low. Conclusion: The diagnostic accuracy of infrared tympanic thermometer was similar to axillary and rectal thermometers indicating a need for further research to substantiate these findings in children with hyperthermia.
Keywords
Thermometer; Sensitivity; Specificity; Meta-analysis; Child;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 van Staaij, B. K., Rovers, M. M., Schilder, A. G., & Hoes, A. W. (2003). Accuracy and feasibility of daily infrared tympanic membrane temperature measurements in the identification of fever in children. International Journal of Pediatric Otorhinolaryngology, 67(10), 1091-1097.   DOI   ScienceOn
2 Walter, S. D. (2002). Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data. Statistics in Medicine, 21(9), 1237-1256. http://dx.doi.org/10.1002/sim.1099   DOI   ScienceOn
3 Wells, N., King, J., Hedstrom, C., & Youngkins, J. (1995). Does tympanic temperature measure up? MCN. The American Journal of Maternal Child Nursing, 20(2), 95-100.   DOI   ScienceOn
4 Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., et al. (2011). QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies. Annals of Internal Medicine, 155(8), 529-536. http://dx.doi.org/10.7326/0003-4819-155-8-201110180-00009   DOI   ScienceOn
5 Wilshaw, R., Beckstrand, R., Waid, D., & Schaalje, G. B. (1999). A comparison of the use of tympanic, axillary, and rectal thermometers in infants. Journal of Pediatric Nursing, 14(2), 88-93. http://dx.doi.org/10.1016/s0882-5963(99)80042-6   DOI   ScienceOn
6 Yun, K. W., & Lim, I. S. (2005). A study for accuracy and usefulness of tympanic membrane and forehead thermometers. Korean Journal of Pediatrics, 48(8), 820-825.
7 Macaskill, P., Gatsonis, C., Deeks, J. J., Harbord, R. M., & Takwoingi, Y. (2010). Chapter 10: Analysing and presenting results. In J. J. Deeks, P. M. Bossuyt & C. Gatsonis (Eds.), Cochrane handbook for systematic reviews of diagnostic test accuracy version 1.0 (pp. 1-47). Oxford, UK: The Cochrane Collaboration.
8 Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009). Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement. Annals of Internal Medicine, 151(4), 264-269, W264.   DOI   ScienceOn
9 National Institute for Health and Clinical Excellence. (2007). Feverish illness in children: NICE guideline. London, UK: Author.
10 Nimah, M. M., Bshesh, K., Callahan, J. D., & Jacobs, B. R. (2006). Infrared tympanic thermometry in comparison with other temperature measurement techniques in febrile children. Pediatric Critical Care Medicine, 7(1), 48-55.   DOI   ScienceOn
11 Robinson, J. L., Seal, R. F., Spady, D. W., & Joffres, M. R. (1998). Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children. The Journal of Pediatrics, 133(4), 553-556.   DOI   ScienceOn
12 Royal College of Nursing. (2011). Standards for assessing, measuring and monitoring vital signs in infants, children and young people: RCN guidance for children's nurses and nurses working with children. London, UK: Author.
13 Selfridge, J., & Shea, S. S. (1993). The accuracy of the tympanic membrane thermometer in detecting fever in infants aged 3 months and younger in the emergency department setting. Journal of Emergency Nursing, 19(2), 127-130.
14 Shenep, J. L., Adair, J. R., Hughes, W. T., Roberson, P. K., Flynn, P. M., Brodkey, T. O., et al. (1991). Infrared, thermistor, and glass-mercury thermometry for measurement of body temperature in children with cancer. Clinical Pediatrics (Phila), 30(4 Suppl), 36-41; discussion 49.   DOI   ScienceOn
15 Sohng, K. Y., Kang, S. S., Hwang, J. S., & Kim, M. J. (1998). Accuracy of temperature measurements, nursing time for measuring temperature and the validity of fever detection. Journal of Korean Academy of Fundamentals of Nursing, 5(1), 33-45.
16 Sohng, K. Y., Park, H. S., Hong, Y. H., Yoon, E. J., Lee, K. Y., Cho, B. H., et al. (2009). Fundamentals of nursing (2nd ed.). Paju: Soomoonsa.
17 Hwang, J. S., & Sohng, K. Y. (1997). Comparison of rectal temperature with axillary and tympanic temperature. Journal of Korean Academy of Fundamentals of Nursing, 4(2), 351-358.
18 Jean-Mary, M. B., Dicanzio, J., Shaw, J., & Bernstein, H. H. (2002). Limited accuracy and reliability of infrared axillary and aural thermometers in a pediatric outpatient population. The Journal of Pediatrics, 141(5), 671-676. http://dx.doi.org/10.1067/mpd.2002.127664   DOI   ScienceOn
19 Jeong, Y. S., & Kim, J. S. (2010). Fever and fever management in children: A literature review. Journal of Korean Academy of Child Health Nursing, 16(1), 30-40. http://dx.doi.org/10.4094/jkachn.2010.16.1.30   DOI   ScienceOn
20 Jeong, I. S., & Yoo, E. J. (1997). Study on the body temperature measuring time and accuracy and reliability of tympanic thermometer. Journal of Korean Academy of Fundamentals of Nursing, 4(1), 19-30.
21 Kim, J. S. (2004). Anesthesia and temperature. Korean Journal of Anesthesiology, 47(5), 609-616.   DOI
22 Kozier, B., Erb, G., Blais, K., & Wilkinson, J. M. (1997). Fundamentals of nursing: Concepts, process, and practice (5th ed.). Redwood City, CA: Addison-Wesley.
23 Lee, G., Flannery-Bergey, D., Randall-Rollins, K., Curry, D., Rowe, S., Teague, M., et al. (2011). Accuracy of temporal artery thermometry in neonatal intensive care infants. Advances in Neonatal Care, 11(1), 62-70. http://dx.doi.org/10.1097/ANC.0b013e3182087d2b   DOI   ScienceOn
24 Lee, J. K., Kim, E. J., Lee, H. K., Yu, Y. H., & Lee, H. S. (1998). The effect of bundling on neonatal body temperature. Journal of the Korean Pediatric Society, 41(1), 26-32.
25 Lee, T. J., & Kim, D. S. (2007). Fever. Korean Journal of Pediatrics, 50(2), 121- 126. http://dx.doi.org/10.3345/kjp.2007.50.2.121   DOI   ScienceOn
26 Lee, Y. K., & Lee, S. M. (2011). Clinical trials and accuracy of diagnostic tests. Journal of Genetic Medicine, 8(1), 28-34. http://dx.doi.org/10.5734/jgm.2011.8.1.28   DOI
27 Liu, C. C., Chang, R. E., & Chang, W. C. (2004). Limitations of forehead infrared body temperature detection for fever screening for severe acute respiratory syndrome. Infection Control and Hospital Epidemiology, 25(12), 1109-1111. http://dx.doi.org/10.1086/502351   DOI   ScienceOn
28 Devrim, I., Kara, A., Ceyhan, M., Tezer, H., Uluda, A. K., Cengiz, A. B., et al. (2007). Measurement accuracy of fever by tympanic and axillary thermometry. Pediatric Emergency Care, 23(1), 16-19. http://dx.doi.org/10.1097/PEC.0b013e31802c61e6   DOI   ScienceOn
29 Edelu, B. O., Ojinnaka, N. C., & Ikefuna, A. N. (2011). Fever detection in under 5 children in a tertiary health facility using the infrared tympanic thermometer in the oral mode. Italian Journal of Pediatrics, 37, 8. http://dx.doi.org/10.1186/18Arch Dis Child. 2006 Apr;91(4):351-6.   DOI   ScienceOn
30 Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006). In a systematic review, infrared ear thermometry for fever diagnosis in children finds poor sensitivity. Journal of Clinical Epidemiology, 59(4), 354-357. http://dx.doi.org/10.1016/j.jclinepi.2005.10.004   DOI   ScienceOn
31 El-Radhi, A. S., & Barry, W. Thermometry in paediatric practice. Archives of Disease in Childhood, 91(4), 351-356.
32 El-Radhi, A. S., & Patel, S. P. (2007). Temperature measurement in children with cancer: An evaluation. British Journal of Nursing, 16(21), 1313-1316.   DOI
33 Erickson, R. S., & Woo, T. M. (1994). Accuracy of infrared ear thermometry and traditional temperature methods in young children. Heart & Lung, 23(3), 181-195.
34 Greenes, D. S., & Fleisher, G. R. (2001). Accuracy of a noninvasive temporal artery thermometer for use in infants. Archives of Pediatrics & Adolescent Medicine, 155(3), 376-381.   DOI   ScienceOn
35 Greiner, M., Pfeiffer, D., & Smith, R. D. (2000). Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests. Preventive Veterinary Medicine, 45(1-2), 23-41.   DOI   ScienceOn
36 Hay, A. D., Peters, T. J., Wilson, A., & Fahey, T. (2004). The use of infrared thermometry for the detection of fever. The British Journal of General Practice, 54(503), 448-450.
37 Higgins, J. P., & Thompson, S. G. (2002). Quantifying heterogeneity in a meta-analysis. Statistics in Medicine, 21(11), 1539-1558. http://dx.doi.org/10.1002/sim.1186   DOI   ScienceOn
38 Hong, Y. S., & Lee, S. O. (1975). An experimental study on the shortest optimum time for body temperature measurement. The Journal of Nurses Academic Society, 5(2), 38-50.   DOI
39 Burke, K. (1996). The tympanic membrane thermometer in paediatrics: A review of the literature. Accident and Emergency Nursing, 4(4), 190-193.   DOI   ScienceOn
40 Brennan, D. F., Falk, J. L., Rothrock, S. G., & Kerr, R. B. (1995). Reliability of infrared tympanic thermometry in the detection of rectal fever in children. Annals of Emergency Medicine, 25(1), 21-30.   DOI   ScienceOn
41 Chamberlain, J. M., Grandner, J., Rubinoff, J. L., Klein, B. L., Waisman, Y., & Huey, M. (1991). Comparison of a tympanic thermometer to rectal and oral thermometers in a pediatric emergency department. Clinical Pediatrics (Phila), 30(4 Suppl), 24-29.   DOI   ScienceOn
42 Chiappini, E., Sollai, S., Longhi, R., Morandini, L., Laghi, A., Osio, C. E., et al. (2011). Performance of non-contact infrared thermometer for detecting febrile children in hospital and ambulatory settings. Journal of Clinical Nursing, 20(9-10), 1311-1318. http://dx.doi.org/10.1111/j.1365-2702.2010.03565.x   DOI   ScienceOn
43 Childs, C., Harrison, R., & Hodkinson, C. (1999). Tympanic membrane temperature as a measure of core temperature. Archives of Disease in Childhood, 80(3), 262-266.   DOI   ScienceOn
44 Craig, J. V., Lancaster, G. A., Taylor, S., Williamson, P. R., & Smyth, R. L. (2002). Infrared ear thermometry compared with rectal thermometry in children: A systematic review. Lancet, 360(9333), 603-609. http://dx.doi.org/10.1016/s0140-6736(02)09783-0   DOI   ScienceOn