• Title/Summary/Keyword: di/dt

Search Result 70, Processing Time 0.019 seconds

Flyback type Snubber Circuit with di/dt Limiting Capability for IGCT in MV Wind Turbines

  • Lee, Kihyun;Song, Seunghoo;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.333-334
    • /
    • 2014
  • Converters employing IGCTs usually require di/dt snubber and Over Voltage Protection (OVP) circuit for the protection of IGCTs and fast diodes. In these IGCT-based converters, conventional di/dt snubber and OVP circuit dissipates a significant amount of power loss. To reduce this loss of conventional di/dt snubber and OVP circuit, this paper proposes a flyback type snubber circuit with di/dt limiting characteristic for IGCT-based converters in medium voltage wind turbines. This flyback type snubber circuit simply consists of a flyback type transformer and diode. The proposed circuit reduces loss and simplifies conventional di/dt snubber by adopting the flyback type transformer. Loss analysis of conventional di/dt snubber and OVP circuit is performed for the 3-level NPC type back-to-back VSC supplied from grid voltage of 6.9kV. The proposed flyback type snubber circuit can save the loss of conventional snubber circuit in the 3L-NPC type back-to-back VSC in multi-MW MV wind turbine. The proposed snubber circuit has a fewer number of components and improved efficiency leading to a reliable and efficient wind turbine systems.

  • PDF

Fault analysis and protection of the DC traction power supply system (전기철도 DC급전시스템의 보호 및 사고전류해석)

  • Chung, S.G.;Lee, B.S.;Jeong, R.K.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.30-33
    • /
    • 2001
  • 도시철도 DC 급전시스템은 부하전류가 사고전류보다 클 수 이는 특징을 가지고 이다. 이러한 이유로 DC 급전시스템에서는 di/dt를 측정하여 사고전류를 부하전류로부터 구분하고 있다. 이것은 사고전류의 di/dt와 부하전류의 di/dt는 서로 다른 상이한 특성을 보이고 있기 때문이다. 본문에서는 DC도시철도급전시스템에서 흔히 사용되는 di/dt 계전기와 이의 설정을 위한 사고전류의 분석 및 설정방법에 대해 알아본다.

  • PDF

CURRENT-CONTROLLED PWM-RECTIFIER WITH di/dt FEEDBACK/VOLTAGE-SOURCE INVERTER WITHOUT DC LINK COMPONENTS FOR INDUCTION MOTOR DRIVE

  • Iimori, Kenichi;Shinohara, Katsuji;Muroya, Mitsuhiro;Kitanaka, Hidetoshi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.524-528
    • /
    • 1998
  • The voltage-source inverters are normally equipped with an electrolytic capacitor in their DC link, however, the electrolytic capacitor has several disadvantages such as increasing size, limiting converter life and reliability. Therefore, several approaches for removing the DC link capacitor have been studied by the authors. This paper proposes a new voltage-source inverter without DC link components. To reduce waveform distortion of the AC source current, the current-controlled PWM-rectifier with di/dt feedback is introduced. The di/dt feedback gain and LC parameters are investigated by calculation for a 0.75kW induction motor driven by this inverter. The calculated AC source currents maintain nearly sinusoidal waveforms with a unity power factor.

  • PDF

Parallel Operation of a Pair of SITs in order to raise the High Frequency and Power Half-Bridge Inverter (고주파 및 고전력 인버터 적용을 위한 Half-Bridge SIT의 병렬운전 특성고찰)

  • Choi, Sang-Won;Kim, Jin-Pyo;Lee, Jong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2234-2236
    • /
    • 1997
  • The SIT, a Static Induction Transistor, is a semiconductor switch that is also called the power junction field-effect transistor (power JFET). Its characteristics are similar to a MOSFET except that its power level is higher and its maximum frequency of operation is lower. The normal method to protect against internal circuit transients of the form of di/dt or dv/dt is the use of snubber circuits. However, the limits of di/dt and dv/dt are high enough for the SIT that it is possible to operate without snubber circuits. SITs can be connected in parallel in order to cope with higher load currents that the value of an individual device rating. The purpose of this study is to investigate the parallel operation of SITs. In this experiment, we used a half-bridge inverter, the output of inverter is up to almost 1MHz and 2kW. Experimental results show that the operation of parallel connected SITs are facilitated individually good current sharing. The reason is the positive temperature coefficient of resistance of the SIT.

  • PDF

Optimal System Design and Minimization of Conducted EMI Noise in Elevator Inverter System by Customized IPM (주문형 IPM을 이용한 엘리베이터용 인버터의 최적화 설계 및 전도 EMI 노이즈 저감)

  • 조수억;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2003
  • This paper deals with the optimal design of a elevator inverter system based on the customized IPM. The proposed method reduces dv/dt and di/dt, which resulted in the minimized conducted EMI noise without an additional circuitry. It only optimizes the value of gate resistor in the IGBT embedded in the IPM. In order to optimize the customized IPM to a elevator system, we simulated and measured the spike voltage and the motor surge voltage including the temperature variation due to the switching losses at the IPM case and heat-sink. As a result, thanks to the optimized value of the gate resister in the IPM, the conducted EMI noise is reduced approx. 5∼10 [dB$\mu$V] in a particular frequency domain.

Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker (직렬-복합소호형 모델 가스차단기의 차단성능평가)

  • 송기동;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.

Design of the Capacitor Discharge Ignition System (용량방전점화장치의 설계)

  • 박송배;김영길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.2
    • /
    • pp.5-13
    • /
    • 1976
  • An analytical and experimental design procedure is described for the Capacitor Discharge Ignition (CDI) System with a view to fuel saving ann reduction of gas exhaustion and maintenance need. Specifically, the input and output voltage and current of a given ignition coil were calculated by using a simplified circuit model for the discharging system. The results were compared with the experimental results, from which ratings of the charging capacitor, the SCR and the diodes and the required output valtage of the DC.DC converter were determined so as to satisfy the optimum ignition conditions. Protection circuits for excessive dv/dt and di/dt for the SCR were also analyzed and the results were compared with the observed results, which facilitate selection of the SCR and design of the protection circuit and the trigger circuit. Also, design of the DC.DC converter was simplified based on the analysis and experimental results of the behavior of the converter, An experimental, yet practical CDI system was built, which showed satisfactory performance in the laboratory and field tests. The results were also reported.

  • PDF

Flux Position Estimation Method of IPMSM by Controlling Current Derivative at Zero Voltage Vector

  • Hosogaya, Yuji;Kubota, Hisao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.84-90
    • /
    • 2012
  • Various methods have been proposed to identify the flux position in an interior permanent magnet synchronous motor (IPMSM) without the use of mechanical sensors. To achieve this, a method that uses both the back electromotive force (EMF) and the saliency to identify the flux position in the IPMSM without the injection of high-frequency components at low speeds has been reported. This method was then extended in order to drive the motor with no load to a light load. We propose a combination of these methods with different proportional-integral (PI) controllers for controlling $di_{dest}$/dt and $di_{qest}$/dt. We also introduce compensation values $F_L$ and $F_H$ to reduce the position error when the estimation rule is being selected.

Design of Snubber for PWM Inverter (PWM 인버터용 SNUBBER 설계)

  • 오진석
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.95-100
    • /
    • 1993
  • In power transistor switching circuit have shunt snubber(dv/dt limiting capacitor) and series snubber (di/dt limiting inductor). The shunt snubber is used to reduce the turn-off switching loss and the series snubber is used to reduce the turn-on switching loss. Design procedures are derived for selecting the capacitance, inductor and resistance to limit the peak voltage and current values. The action of snubber is analyzed and applied to the design for safety PWM inverter.

  • PDF

A Study on Oral Health Condition According to Intake Frequency by Food Groups (식품군별 섭취 빈도에 따른 구강 건강상태 검진 조사 -국민건강영양조사 제5기 원시자료에 근거하여-)

  • Kim, Ji-Hye;Lee, Mi-Hee;Kim, Hye-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1010-1019
    • /
    • 2014
  • This study applied an original survey of an objective National Health Nutriment Research. It picked the youth up from 14 years old to 19 years old and examined an influence relationship of four heads such as DT, DI, DMFT, DMFI which investigated in heads of dental inspections based on an intake frequency questionnaire by food group. It was proved that Korean dietary culture which eats rice and kimchi as staple food had an great effect on DT, DI, DMFT, DMFI And rice and cereals, fruits and vegetables like a cabbage turned out to be factors that can lower dental caries. The dental caries can be reduced by the more intake frequency of rice. And also, intake of fish like anchovy and meats like pork and beef can reduce development of dental caries too. Especially, the larger intake frequency of carbonated drinks and fast food such as hamburger and pizza can make a growth of dental caries.