• 제목/요약/키워드: deviation of position

검색결과 517건 처리시간 0.021초

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

Robust concurrent topology optimization of multiscale structure under load position uncertainty

  • Cai, Jinhu;Wang, Chunjie
    • Structural Engineering and Mechanics
    • /
    • 제76권4호
    • /
    • pp.529-540
    • /
    • 2020
  • Concurrent topology optimization of macrostructure and microstructure has attracted significant interest due to its high structural performance. However, most of the existing works are carried out under deterministic conditions, the obtained design may be vulnerable or even cause catastrophic failure when the load position exists uncertainty. Therefore, it is necessary to take load position uncertainty into consideration in structural design. This paper presents a computational method for robust concurrent topology optimization with consideration of load position uncertainty. The weighted sum of the mean and standard deviation of the structural compliance is defined as the objective function with constraints are imposed to both macro- and micro-scale structure volume fractions. The Bivariate Dimension Reduction method and Gauss-type quadrature (BDRGQ) are used to quantify and propagate load uncertainty to calculate the objective function. The effective properties of microstructure are evaluated by the numerical homogenization method. To release the computation burden, the decoupled sensitivity analysis method is proposed for microscale design variables. The bi-directional evolutionary structural optimization (BESO) method is used to obtain the black-and-white designs. Several 2D and 3D examples are presented to validate the effectiveness of the proposed robust concurrent topology optimization method.

가공력 제어 위치 서보 시스템을 이용한 초음파 가공기의 개발 (Development of Ultrasonic Machine with Force Controlled Position Servo System)

  • 장인배;이승범;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.253-261
    • /
    • 2004
  • The machining technology for the brittle materials such as ceramics are applied to the fields of MEMS(micro electromechanical system) by the progress of new machining technologies such as Etching, Diamond machining, Micro drilling, EDM(Electro discharge machining), ECDM(Electro discharge machining), USM(Ultrasonic machining), LBM(Laser beam machining), EBM(Electron beam machining). Especially, the USM technology can be applied to the dieletric brittle materials such as silicon, borosilicate glass, silicon nitride, quartz and ceramics with high aspect ratio. The micro machining system with machining force controlled position servo is developed in this paper and the optimized ultrasonic machining algorithm is constructed by the force controlled position servo control. The load cell is adapted in the force measuring and the servo control algorithm, suit for the ultrasonic machining characteristics, is estabilished with using the PID auto-tunning functions at the PMAC system which is generally adapted in the field of robot industries. The precision force signal amplifier is constructed with high precision operational amplifier AD524. The vacuum adsorption chuck which is made of titanum and internal flow line is engraved, is used in the workpiece fixing. The mahining results by USM shows that there are some deviation between the force command and the actual machining force that the servo control algorithm should be applied in the machining procedures. Therefore, the constant force controlled position servo system is developed for the micro USM system and by the examination machining process in USM, the stable USM system is realized by tracking the average value of machining force.

A Study on Pressure Distribution for Uniform Polishing of Sapphire Substrate

  • Park, Chul jin;Jeong, Haedo;Lee, Sangjik;Kim, Doyeon;Kim, Hyoungjae
    • Tribology and Lubricants
    • /
    • 제32권2호
    • /
    • pp.61-66
    • /
    • 2016
  • Total thickness variation (TTV), BOW, and surface roughness are essential characteristics for high quality sapphire substrates. Many researchers have attempted to increase removal rate by controlling the key process parameters like pressure and velocity owing to the high cost of consumables in sapphire chemical mechanical polishing (CMP). In case of the pressure approach, increased pressure owing to higher deviation of pressure over the wafer leads to significant degradation of the TTV. In this study, the authors focused on reducing TTV under the high-pressure conditions. When the production equipment polishes multiple wafers attached on a carrier, higher loads seem to be concentrated around the leading edge of the head; this occurs because of frictional force generated by the combination of table rotation and the height of the gimbal of the polishing head. We believe the skewed pressure distribution during polishing to be the main reason of within-wafer non-uniformity (WIWNU). The insertion of a hub ring between the polishing head and substrate carrier helped reduce the pressure deviation. Adjusting the location of the hub ring enables tuning of the pressure distribution. The results indicated that the position of the hub ring strongly affected the removal profile, which confirmed that the position of the hub ring changes the pressure distribution. Furthermore, we analyzed the deformation of the head via finite element method (FEM) to verify the pressure non-uniformity over the contact area Based on experiment and FEM results, we determined the optimal position of hub ring for achieving uniform polishing of the substrate.

자세변화가 자율신경계에 미치는 영향 (The Influence of Position Change on Autonomic Nervous System Function)

  • 김인배;김은경;강종호
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

WPS 측위 편차폭을 줄이기 위한 확률적 접근법 (Probabilistic Method to reduce the Deviation of WPS Positioning Estimation)

  • 김재훈;강석연
    • 한국통신학회논문지
    • /
    • 제37권7B호
    • /
    • pp.586-594
    • /
    • 2012
  • 무선인터넷과 이동통신 기술의 발달 및 스마트폰의 급속한 확산으로 인해 사용자의 현재 및 과거의 위치 정보를 사용하여 다양한 부가정보를 제공하는 위치기반 서비스에 대한 관심이 급증하고 있다. 위치기반 서비스의 본격적인 활성화를 위해서는 정확한 측위가 기본이 된다. 본 논문에서는 Access Point의 위치를 확률적으로 추정하여 AP 분포 지도를 구성하여 이를 위치 추정에 사용하는 기법을 제공한다. 특히 전파지문 기반의 Wi-Fi Positioning Ssystem이 발전할수록 데이터 필터링, 측위 알고리즘과 같은 기술적 기법의 향상에 주목을 하여야 보다 차별적인 품질의 측위 결과를 얻어낼 수 있는데 본 논문에서는 Access Point 위치의 확률 분포를 구하여 이를 측위에 적용하는 방식을 제안하여 기존의 방식과 비교하여 평균과 편차폭 모두 상당한 향상을 가져왔음을 보인다. 또한 본 연구는 전파지문 패턴의 수집에 있어 서울 지역의 실제 데이터를 활용하였고 이를 대규모로 적용할 수 있는 기반을 구성했다는 면에서도 충분한 의미를 지닌다.

정상 한국인 성인 남녀에서 협골을 중심으로 한 중안모의 측모 두부방사선 규격사진 분석법 (A LATERAL CEPHALOMETRIC ANALYSIS OF MIDFACE FOCUSING ON ZYGOMATIC BONE IN KOREAN ADULTS)

  • 이의훈;정인교
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제21권4호
    • /
    • pp.353-359
    • /
    • 1999
  • Purpose : A new method of lateral cephalometric analysis for midface, focusing on zygomatic bone, was created in this study, and measured in Korean adults. The purposes of this study are understanding about new approach for midfacial depression, especially zygomatic bone, and using to make adequate diagnosis and treatment plan. Materials and methods : In this study, esthetic Korean adults, 25 males and 25 females who were between $0^{\circ}$ and $4^{\circ}$ in ${\angle}ANB$, and between 62% and 70% in P/A facial height ratio, and had normal overbite and overjet, were used. Orbitale(Or) and Soft tissue orbitale(Or') were used for indicators of anteroposterior position of zygomatic area. And, mean value and standard deviation of linear and angular measurements, and ratio about each linear measurements, were obtained. then, standard deviation diagram - wiggle diagram - was made for visualization of results. Results : Mean values, standard deviations and ranges of 19 measurements were obtained, and among them, 5 linear measurements that had large standard deviation were excluded and the others were used for making standard deviation diagram. In standard deviation diagram, the following results were obtained. 1. If the measurements are located on more left side of mean-value-vertical -line, the potential of midfacial hypoplasia are stronger, especially zygomatic area. 2. If the measurements are located on more right side of mean-value-vertical-line, the potential of midfacial hypoplasia are decreased. Conclusion : This study presented a new method of lateral cephalometric analysis focusing on zygomatic bone in Korean adults. We expect that the results of this study can be used as parameter when clinicians make decisions about diagnosis and treatment plan for rehabilitation of esthetics and function. But, it is necessary to prove its usefulness, and to further evaluate the results.

  • PDF

정지궤도위성 탑재용 실시간 궤도요소 생성기 (On-board Realtime Orbit Parameter Generator for Geostationary Satellite)

  • 박봉규;양군호
    • 항공우주기술
    • /
    • 제8권2호
    • /
    • pp.61-67
    • /
    • 2009
  • 본 논문은 정지궤도위성에 탑재 가능한 저 계산량의 궤도데이터 생성 알고리즘을 제안하고 있다. 제안하는 알고리즘의 기본적인 개념은 지상에서 생성된 기준궤도에 대한 변위 정보를 48시간에 대하여 30분 간격으로 생성한 다음, 위성에 업로드 한다. 위성에서는 업로드된 변위정보를 테이블 형태로 저장하고, 원하는 시간에 근접한 세 개의 데이터 셋을 취한 다음 이차함수 보간법 적용하여 원하는 시간에 대한 변위정보를 계산한다. 생성된 변위 정보는 다시 기준궤도에 더해져 최종적인 궤도성분을 복구하도록 한다. 여기서 기준궤도는 이심율과 궤도 경사각이 0인 이상적인 정지궤도를 의미한다. 본 알고리즘을 이용할 경우 1Hz이상의 속도로 궤도정보를 생성하여 요구하는 탑재체에 공급 할 수 있는 장점이 있다. 본 알고리즘은 48시간에 대한 궤도 변위 정보를 저장하기 위하여 3킬로바이트 이내의 추가적인 메모리를 요구한다. 이러한 수치는 정지궤도위성에서 충분히 지원 가능한 수치로 판단된다.

  • PDF

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

저유속 영역에서 대구경 전자기유량계의 오차특성 연구 (A Study on Error Characteristics of Large Size Electromagnetic Flowmeter in the Range of Low Velocity)

  • 이동근;박종호
    • 대한기계학회논문집B
    • /
    • 제32권3호
    • /
    • pp.235-240
    • /
    • 2008
  • The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from $0.05\;^m/s\;to\;0.6\;^m/s$ with increment of $0.05\;^m/s$. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ${\pm}0.4%$ of rate both higher than $0.25^m/s$ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for ${\Phi}400mm\;and\;{\Phi}600mm$ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size.