• Title/Summary/Keyword: development of measurement tool

Search Result 528, Processing Time 0.028 seconds

Development of Calibration Instrument far Tool Wear Measurement using Spindle Orientation Function in End Milling (엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸측정 보정 장치의 개발)

  • 강익수;김전하;강명창;김정석;김기태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.149-153
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure tool wear and evaluated by measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces measuring time compared with measuring methods such as the microscope and CCD.

  • PDF

Development of Reliability Measurement Method and Tool for Nuclear Power Plant Safety Software (원자력 안전 소프트웨어 대상 신뢰도 측정 방법 및 도구 개발)

  • Lingjun Liu;Wooyoung Choi;Eunkyoung Jee;Duksan Ryu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.5
    • /
    • pp.227-235
    • /
    • 2024
  • Since nuclear power plants (NPPs) increasingly employ digital I&C systems, reliability evaluation for NPP software has become crucial for NPP probabilistic risk assessment. Several methods for estimating software reliability have been proposed, but there is no available tool support for those methods. To support NPP software manufacturers, we propose a reliability measurement tool for NPP software. We designed our tool to provide reliability estimation depending on available qualitative and quantitative information that users can offer. We applied the proposed tool to an industrial reactor protection system to evaluate the functionality of this tool. This tool can considerably facilitate the reliability assessment of NPP software.

A literature review on measurement tools for dental hygienist turnover intention in Korea (치과위생사 이직의도에 관한 측정도구의 고찰)

  • Park, Soo-Auk;Lee, Ju-Yul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.1-17
    • /
    • 2019
  • This study investigates the overall research trends and related factors affecting the turnover of dental hygienists in Korea during the past 10 years (2007-2017) and analyzed the differences in the results of the research according to the main measurement tools. The literature review focused on turnover of dental hygienists in Korea. Inclusion criteria of selected studies were as follows: the domestic and foreign academic journals and theses published for the past 10 years (between 2007-2017). The most commonly used tool for measuring dental hygienist turnover was a tool developed by Lawler. The most used significant general characteristics is age and income, Job satisfaction (57.1%) and organizational commitment (40.0%) were the most frequently used predictors of turnover. The variables used for each turnover measurement tool were different, showing that the study results was different from according to the variables and significance level. Although there have been many studies related to the turnover of dental hygienists, different results have been shown depending on the measurement tools. When conducting research related to dental hygienist turnover, specific and clear presentation of measurement tool selection or development is needed.

Ultra-Precision Machining Using Fast Tool Servo and On-Machine Form Measurement of Large Aspheric Mirrors (Fast Tool Servo를 이용한 대구경 반사경의 초정밀 가공 및 기상 형상 측정)

  • 김의중;송승훈;김민기;김태형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.129-134
    • /
    • 2000
  • This paper presents the development of ultra-precision machining process of large aspheric aluminum mirrors with a maximum diameter of 620 mm. An ultra-precision machine, "Nanoturn60", developed by Daewoo Heavy Industries Ltd. is used for machining and motion errors of the machine are compensated by using the FTS developed by IAE(Institue for Advanced Engineering) during the machining process. To check the form accuracy of machined aspheric surfaces, on-machine form measurement system is developed. This measurement system consists of air bearing touch probe, straight edge, and laser sensor. With in-process error compensation by FTS(Fast Tool Servo), aspheric mirrors with the from accuracy of submicron order are obtained. obtained.

  • PDF

A Study on the Development of Measurement Setup for Crater Wear by Diffraction Grating in Turning (선삭에서 회절격자를 이용한 크레이터마모 측정장치 개발에 관한 연구)

  • Kim, Yeong-Il;Kim, Se-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-95
    • /
    • 1992
  • There is the high interest for sensing of tool wear with the aim of controlling machine tools productivity from the point of view of qualitity. Difficulties in this measurement are also known. This study is on the development of measurement setup for crater wear by CCD image inturning. In this study, the crater wear measurement system consists of the He-Ne gas laser, diffraction grating. CCD camera, noise filter, slit, microcomputer, diverging lens, converging lens and so on. He-Ne laser beam passes through a diverging lens and a diffraction grating is positioned properly. A converging lens focuses so that the interference fringes can be obtained on the crater wear. Performance test revealed that the developed image technique provides precise, absolute tool-wear quantification and reduces human measurement errors. The results obtained are as follows 1. The digitizing of one image requires less than 2ses. 2. It can give detailed information on crater wear with limited times and errors 3. All parameters required by specification are easily obtained for several points of the cutting edge.

  • PDF

Development and Evaluation of Job Stress Measurement Tool for Infection Control Nurses (감염관리간호사의 직무 스트레스 측정도구 개발 및 평가)

  • Her, Sun;Kim, Kye Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.19 no.5
    • /
    • pp.622-635
    • /
    • 2013
  • Purpose: The purpose of this study was to develop and evaluate a tool to measure job stress related to occupational characteristics of infection control nurses. Methods: The tool was developed through the steps of literature reviews, preparatory questions, and a test of validity and confidence. The participants were 212 infection control nurses from 145 Korean hospitals. Data were analyzed using descriptive statistics, Cronbach's ${\alpha}$ coefficients, item analysis, factor analysis. Results: Through factor analysis, 38 items in four domains and nine factors were derived. The Cronbach's ${\alpha}$ coefficient of the final instrument was .95. Conclusion: The results of this study indicate that the measurement tool is reliable and valid to measure the job stress of infection control nurses.

Development of Performance Measures Based on Nursing Process for Fluid Intake/Output and Tube Care (간호과정 적용 평가도구 개발 -수분섭취/배설간호와 튜브간호를 중심으로-)

  • Kim, Keum Soon;Choi, Yun Kyoung;Choi, Wan Hee;Ahn, Jung Won;Kim, Jin A;Park, Seung Mi;Choi, Kyung Ok;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.13-28
    • /
    • 2012
  • Purpose: This study was conducted to develop standards ensuring nursing process-based fluid intake/output and tube care, and to develop a performance measurement tool evaluating the level of care according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined using a survey of 293 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 3.86 and 4.02, respectively, out of 5.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care for fluid intake/output and tubes. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for fluid intake/output and tube interventions, such as intravenous catheters, nasogastric tube and urinary catheters.

Development of Performance Measures Based on Nursing Process for Admission and Discharge Care (간호과정 적용 평가도구 개발 -입원 및 퇴원 시 간호를 중심으로-)

  • Kim, Keum Soon;Kim, Jin A;Choi, Yun Kyoung;Kim, Eun Man;Kim, Yu Jeong;Kim, Mi Ae;Kim, Kyoung Ok;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.123-137
    • /
    • 2011
  • Purpose: This study was conducted to develop standards ensuring nursing process-based care of patient admission and discharge, to develop a performance measurement tool evaluating the care applied according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined through surveying a total of 302 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 4.11 and 4.09, respectively, out of 5.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care provided at patient admission and discharge. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for patient admission and discharge.

Development of a Vision Based Machine Tool Presetter (영상 기반 머신툴 프리세터 개발)

  • Jung, Ha-Hyoung;Kim, Tae-Tean;Park, Jin-Ha;Lyou, Joon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • Generally, the tool presetter is utilized to align and measure some specific dimensions of a machine tool. It is classified into two types(contact and contactless) according to the measurement method, and the optical sensor based contactless scheme has the advantages of measurement flexibility and convenience. This paper describes the design and realization of an industrial tool presetter using machine vision and linear scaler. Before measurement, the objective tool is attached to the mechanical mount and is aligned with the optical apparatus. After capturing tool images, the suggested image processing algorithm calculates its dimesions accurately, combining the traversing distance from the linear scaler. Experimental results conforms that the present tool presetter system has the precision within ${\pm}20um$ error.