• Title/Summary/Keyword: developing test

Search Result 3,416, Processing Time 0.039 seconds

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

Ductility and Seismic Performance of Spirally Reinforced Bridge Columns (나선철근 원형교각의 연성 및 내진성능)

  • 이재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.356-363
    • /
    • 2000
  • The objectives of this study are to investigate seismic performance of spirally reinforced bridge columns and to provide test result for developing improved seismic design criteria. Quasi-static test was conducted for 12 columns of which variables were transverse reinforcement ratio and spacing, longitudinal reinforcement ratio, and axial load level. Sufficient seismic performance was observed from the test for the columns with greater confinement steel amount than the requirement of the Korean Bridge Design Specification. The columns with 0.84% of the confinement steel requirement provided adequate performance under less than 0.2 of axial load level, but showed lower ductility under 0.3 of axial load level. The current provision for the region of confinement steel distribution may be non-conservative under high axial load level, therefore a modified provision is proposed.

  • PDF

Biomechanical Fatigue Analysis of Cervical Plate Systems by using a Computer Simulation Based on Finite Element Method (유한요소법을 이용한 척추 삽입형 경추판 시스템에 대한 생체역학적 피로해석)

  • Kim, Sung-Min;Yang, In-Chul;Cho, Sung-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.96-103
    • /
    • 2008
  • In this study, we performed the biomechanical analysis of cervical plate systems by using a computer simulation based on finite element method to derive reliable model by analysis of design variables and fatigue behavior. To simulate the cervical spine movement in-vivo state by surgery, we modeled the cervical plate system which consisted of screws, rings, rivets, and plate and Ultra High Molecular Weight Polyethylene (UHMWPE) Block. The experiment of cervical plate system followed the ASTM F1717 standards that covered the materials and methods for the static and fatigue testing. The result of computer simulation is compared with experimented test. We expected this study is to derive reliable results by analysis of design variables and fatigue behavior for developing a new model.

Formal tests for State-model based Specifications on Software Components (상태모델에 기반한 소프트웨어 컴포넌트 명세의 정형적 테스트)

  • Seo, Dongsu
    • The Journal of Korean Association of Computer Education
    • /
    • v.7 no.6
    • /
    • pp.129-139
    • /
    • 2004
  • In developing highly reliable systems such as C4I systems formal methods provide both developers and clients with assurance that they are in the right development processes. This paper investigates into techniques for formal specifications and tests for software components where rigorous verification is required. In particular, the paper suggests decomposition techniques for state-model based specifications using the weakest precondition, and suggests test methods for the specification by generating black box test-cases.

  • PDF

Investigation of Terminology Coverage in Radiology Reporting Templates and Free-text Reports

  • Hong, Yi;Zhang, Jin
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 2015
  • The Radiological Society of North America (RSNA) is improving reporting practices by developing an online library of clear and consistent report templates. To compare term occurrences in free-text radiology reports and RSNA reporting templates, the Wilcoxon signed-rank test method was applied to investigate how much of the content of conventional narrative reports is covered by the terms included in the RSNA reporting templates. The results show that the RSNA reporting templates cover most terms that appear in actual radiology reports. The Wilcoxon test may be helpful in evaluatingexisting templates and guiding the enhancement of reporting templates.

Corpus-based evaluation of French text normalization (코퍼스 기반 프랑스어 텍스트 정규화 평가)

  • Kim, Sunhee
    • Phonetics and Speech Sciences
    • /
    • v.10 no.3
    • /
    • pp.31-39
    • /
    • 2018
  • This paper aims to present a taxonomy of non-standard words (NSW) for developing a French text normalization system and to propose a method for evaluating this system based on a corpus. The proposed taxonomy of French NSWs consists of 13 categories, including 2 types of letter-based categories and 9 types of number-based categories. In order to evaluate the text normalization system, a representative test set including NSWs from various text domains, such as news, literature, non-fiction, social-networking services (SNSs), and transcriptions, is constructed, and an evaluation equation is proposed reflecting the distribution of the NSW categories of the target domain to which the system is applied. The error rate of the test set is 1.64%, while the error rate of the whole corpus is 2.08%, reflecting the NSW distribution in the corpus. The results show that the literature and SNS domains are assessed as having higher error rates compared to the test set.

Development of Low-Cycle Fatigue Test Rig in Simulated PWR Environments (PWR환경을 모사한 저주기 피로실험장치 국산화)

  • Jeong, I.S.;Kim, S.J.;Lee, Y.S.;Hong, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.178-183
    • /
    • 2004
  • For developing fatigue design curve of cast stainless steels that would be used in piping material of domestic nuclear power plants, a low-cycle fatigue test rig was built. It is capable of performing tests in pressurized high temperature water environment of PWR. Cylindrical specimens of CF8M were used for the strain-controlled environmental fatigue tests. Fatigue life was measured in terms of the number of cycles with the variation of strain amplitude at 0.04%/s strain rates. The disparity between target length and measured length of specimens was corrected by using finite element method. The corrected test results showed similar fatigue life trend with another previous results.

  • PDF

The Development of Performance Evaluation System for Air-Operated Actuaotr (공기구동기 성능평가 시스템 개발)

  • Cho T.D.;Yang S.B.;Lee H.Y.;Yang S.M.;Kwon B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1770-1773
    • /
    • 2005
  • The performance evaluation of AOV(air-operated valve) requires the processes to confirm the actuator system capability. It is necessary to evaluate the thrust of the air actuator for the margin evaluation. In this paper, to evaluate and analysis the air actuator, the performance test system and operating program are developed. This system is composed of several sensors such as pressure sensor, LVDT, and LoadCell which are used to get the data for evaluation. The LabVIEW was used for developing the operating program. The test system and operating program are proved through the actual test of the diaphragm actuator.

  • PDF

An Experimental Study on Freezing and Thawing Resistance of Rice Straw Ash Concrete (볏짚재 콘크리트의 동결융해 저항성에 관한 실험적 연구)

  • 김영익;성찬용;김경태;서대석;남기성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.161-166
    • /
    • 1998
  • This experiment was on purpose to estimate freezing and thawing resistance concering with developing rice straw ash concrete which were mixed rice straw ash to cement as ratio of cement weight. Freezing and thawing test was done by Method A of KS F 2456. It could estimate change of original mass, pulse velocity and dynamic modulus of elasticity during test. Test results showed that 5% filled rice straw ash concrete had the highest durability factor(DF) as 86 and from 5% to 7.5% filled rice straw ash concrete showed higher DF than normal cement concrete.

  • PDF

A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles (외관불량 배전용 콘크리트전주 건전도 평가지표 개발)

  • Wong, Yoon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.