• Title/Summary/Keyword: deterioration class

Search Result 92, Processing Time 0.032 seconds

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

전력선통신 기반 A/V 신호 송수신기 설계 및 특성분석

  • Kim, Ji-Hyeong;Kim, Yong-Gap
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.285-285
    • /
    • 2009
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal.

  • PDF

A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

System Design of High-Definition Media Transceiver based on Power Line Communication and Its Performance Analysis (전력선 통신 기반 HD급 미디어 전송 시스템 설계 및 성능 분석)

  • Kim, Ji-Hyoung;Kim, Kwan-Woong;Kim, Yong-K.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.192-196
    • /
    • 2010
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. The strength of the PLC has no more additional wiring work. PLC has also possible to high quality data transmission with currently electrical cable. It has a various strong point campare with existing wire and wireless communication technologies. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. The video function was used for the VEDEO TEST GENERATOR in order to a property valuation. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal. It can be possible to have HD class Media service through the PLC.

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.

A Study on Effect of Coating Stain on the Performance of Electric Cable (도장 오염이 Electric Cable의 성능에 미치는 영향 연구)

  • Cho, Yeon-Ho;Lee, Sang-Hyeok;Son, Young-Shuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.18-23
    • /
    • 2009
  • After the installation of electric cables at block, PE(pre-erection) and hull stages, the coating stains on the electric cable sheath were unavoidably occurred by additional painting process. According to class rules paint or coating applied on the electric cables shall not adversely affect the mechanical, chemical of fire resistant characteristics of the electric cable sheath. However, there has not been quantitatively studied about the effect of coating stains on properties of sheath materials. In this study, we tried to investigate the effect of coating stains on the performance and deterioration of sheath materials by using FTIR, SEM analysis, flame retardant, high potential voltage and tensile test. The results sowed that coating stains, which were occurred during painting work on site could not adversely affect on the performance and deterioration of sheath materials.

  • PDF

Field Research for the Durability Assessment Factor for deriving the Carbonation of Concrete Bridges in the Marine Environment (해양 환경하 콘크리트 교량의 탄산화 내구성능 평가 인자 도출을 위한 현장조사 연구)

  • Chai, Won-Kyu;Lee, Myeong-Gu;Son, Young-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.102-109
    • /
    • 2015
  • In this study, on the basis of the results of the field survey and the theoretical consideration for Korean Standard Specification for concrete durability and maintenance, the following conclusions are derived. From the survey, the prediction equation of carbonation depth for the southwest region in Korea is experimentally proposed, $y_p=5.865{\sqrt{t}}$, which predicts about 60mm of the carbonation depth for the concrete structures of 100 years, a 1st class of target endurance period, under a combined deterioration environment like a marine environment. Considering that the marginal value for a carbonation depth limitation under very severely marine environment is 25mm, in accordance with the Specification, it is found that the predicting carbonation depth for the concrete cover depths, 100mm and 60mm are 63mm and 29.4mm, respectively. In conclusion, according to the equation and the Specification, it is strongly required that the reinforced concrete structures with the cover depth under 100mm have to make a protection from combined deterioration factors by any methods like a surface coating, an increment of cover depth or an application of a special concrete.

Use Impacts on Environmental Deteriorations on and around Trails in Odaesan National Park (오대산 국립공원 이용에 따른 등산로 및 주변환경훼손)

  • 권태호;오구균;이준우
    • Korean Journal of Environment and Ecology
    • /
    • v.9 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • 5 major trails of Odaesan National Park were selected to investigate the use impacts on environmental deterioration of trail accreding to the different amunt of use. The entire width, bare width, maximum depth and slope of trail as the trail comdition surveyed at the total of 120 points were significantly greater on the more heavily-used trail. Major deterioration types of trail were root-exposure, rock-exposure, deepening and divergence in order of frquency and trail conditions of deteriorated points were significantly different from those of non-deteriorated points. The damaged area more severe than Class 4 on trail reached about 379m$^{2}$/km in total, and especcially about 1,196m$^{2}$/km in the section between Chodmyolbogung and Pirobong of Sangwonsa trail. The dominant trees of trail edge vegetation could be Quercus mongolica in upper layer, but in lower layer Rhododecdron schilipenbachii for slope and Actinidia arguta for ridge. Coverage and number of individuals of lower vegetation in trail edge were the lowest on the Sangwonsa trail of the largest use amount, and each trail was dissimilar in species composition of lower layer of edge vegetation.

  • PDF

Effect of Deoxygenizer on the Suppression of Lipid Deterioration of Boiled and Dried-Anchovy Engraulis japonica

  • JEONG Bo-Young;SEO Hae-Jeom;MOON Soo-Kyung;PYEUN Jae-Hyeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.6
    • /
    • pp.770-778
    • /
    • 1995
  • Anchovy Engraulis japonica boiled and dried was stored at $20^{\circ}C$ for 5 months after that treatment of sodium-erythorbate (Na-ery) or deoxygenizer (Deoxy). During storage, peroxide value (POV), thiobarbituric acid (TBA) value, lipid content, and lipid class compositions were determined to evaluate the quality of the samples. pay was decreased rapidly for the first 3 months storage and its decrease was Deoxy group>Control group>Na-ery group in that order. TBA values increased for the first 4 months and then decreased rapidly, and it's increase was the highest in Control group, followed by Na-ery and Deoxy group. Total lipid contents in all samples declined during storage. Especially, phospholipid decreased mainly in Na- ery and Deoxy group, while neutral lipid mainly in Control group. Triglyceride (TG), phosphatidylethanolamine(PE), and phosphatidylcholine(PC) decreased, while free fatty acid (FFA) and lyso-PC (LPC) increased during storage. The decrease of TG was the highest in Control group and that of PE and PC was higher in Na-ery group than in other sample. The decrease of PE in all samples (except Deoxy group) was higher than that of pc. The increase of FFA and LPC were higher in Control and Na-ery group than in Deoxy group. These results indicated that the lipid deterioration of the boiled and dried-anchovy was effectively suppressed by the enclosed deoxygenizer during storage at $20^{\circ}C$.

  • PDF

Use Impacts on Environmental Deteriorations of Trail and Campsite in Tokyusan National Park (덕유산 국립공원 등산로 및 야영장의. 환경훼손에 대한 이용영향)

  • 권태호;오구균;이준우
    • Korean Journal of Environment and Ecology
    • /
    • v.7 no.2
    • /
    • pp.241-251
    • /
    • 1994
  • Use impacts on environmental deteriorations were studied on the four major trails and a campsite of Tokyuksan National Park in 1993. The entire width, bare width, maximum depth and slope of trail as the trail condition were significantly greater on the more heavily used trail. Percentages of rock-exposed, deepening, root-exposed points as the deterioration types of trail which were surveyed at the total of 106 points were higher and trail conditions were significantly different from those of non-deteriorated points. On the Paekryon trail, the damaged area more severe than Class 4 reaches about 910$m^2$/km and the use impact and deterioration on campsites were accelerated. The dominant trees of the the upper and lower layer in trail edge vegetation could be Quercus serrata and Acer pseudo-sieboldianum for Paekryon trail, Q. mongolica and Tripterigium regelii for the other trails. A. pseudo-sieboldianum, Q. serrata, Rhus trichocarpa, Fraxinus sieboldiana, Lespedeza maximowiczii, Symplocos chinensis for Pilosa were classified for tolerant species to use impacts.

  • PDF