• 제목/요약/키워드: detector combination

Search Result 116, Processing Time 0.026 seconds

The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

Hue-based Noise-tolerant Corner Detector Robust to Shadows (그림자에 강건한 색상 기반 내잡음성 코너 검출자)

  • 박기현;박은진;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.6
    • /
    • pp.239-245
    • /
    • 2004
  • A hue-based noise-tolerant corner detector is proposed for the exact detection of the real corners in spite of the shadows and random noise. Based on the fact that the hue gradient at the border of the opaque objects' shadow is smaller than the intensity gradient in HSI (hue-saturation-intensity) color space, the effects of shadow are eliminated by introducing the hue-weighted combination of vector gradient to the proposed corner detector. Furthermore, the proposed corner detector is robust to random noise by offsetting the contribution to the corner candidate when the polarities of the color gradients of the pixel pairs are out of phase each other. Results of the experiment show that the proposed corner detector can effectively detect the real corners.

A Study on Spine and Rib Properties for Standoff Compensation, Density Log (밀도검층 이격 보정을 위한 기준선과 이격선의 특성 연구)

  • Kim, Yeonghwa;Kim, Jongman
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.190-198
    • /
    • 2012
  • A series of density log data were obtained from the standoff experiments made in the four physical model boreholes of different densities, and the properties of spine and rib curves have been derived by the analysis of the gamma-gamma data. Particularly, the shape of gamma ray propagation path between source and detector, the geometrical property of spine and rib curves, the influence of borehole density and the detector combination on the properties of the curves, and the adequate detector combination for standoff compensation could be discussed. It was also confirmed that spine and rib slopes can be expressed as proportional to source-to-detector distance ratio between far and near detectors. The result of this experiment was also effectively applied for understanding the basic concept of spine and rib slopes.

Analysis of the Generalized Order Statistics Constant False Alarm Rate Detector

  • Kim, Chang-Joo;Lee, Hwang-Soo
    • ETRI Journal
    • /
    • v.16 no.1
    • /
    • pp.17-34
    • /
    • 1994
  • In this paper, we present an architecture of the constant false alarm rate (CFAR) detector called the generalized order statistics (GOS) CFAR detector, which covers various order statistics (OS) and cell-averaging (CA) CFAR detectors as special cases. For the proposed GOS CFAR detector, we obtain unified formulas for the false alarm and detection probabilities. By properly choosing coefficients of the GOS CFAR detector, one can utilize any combination of ordered samples to estimate the background noise level. Thus, if we use a reference window of size N, we can realize $(2^N-1)$ kinds of CFAR processors and obtain their performances from the unified formulas. Some examples are the CA, the OS, the censored mean level, and the trimmed mean CFAR detectors. As an application of the GOS CFAR detector to multiple target detection, we propose an algorithm called the adaptive mean level detector, which censors adaptively the interfering target returns in a reference window.

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Low-Noise Detector Design for Measuring the Electric Conductivity of Liquids (액체의 전기 전도도 측정을 위한 저잡음 검출기 설계)

  • Kim, Nam Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.287-292
    • /
    • 2012
  • In this paper, design of a conductivity detector using a synchronous demodulation is presented to detect the electric conductivity of liquids with low noise. For the purpose, the detector is constructed by the combination of a carrier generator, conductivity detecting cell, and synchronous demodulator. The signal-to-noise ratio(SNR) of the detector is improved by adjusting the frequency bandwidth of the demodulator, whereby infinitesimal conductivity signals can easily be measured under various noise environments. As an application example, a conductivity detector, which is applied to the air monitoring in a fabrication process of semiconductor chips, is designed using the synchronous demodulation. The validity of the design technique is verified by experiments. Since experimental results are shown to approach the design performance of the detector, the synchronous demodulation proves to be useful to the design of a conductivity detector for measuring the infinitesimal electric conductivity of liquids.

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

Performance of LDPC with Message-Passing Channel Detector for Perpendicular Magnetic Recording Channel (수직자기기록 채널에서 LDPC를 이용한 메시지 전달 방식의 채널 검출 성능비교)

  • Park, Dong-Hyuk;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4C
    • /
    • pp.299-304
    • /
    • 2008
  • For perpendicular magnetic recording channels, it is hard to expect improving the performance by using the PRML or NPML. Hence, we exploit LDPC code to improve the performance. In this paper, we examine a single message-passing detector/decoder matched to the combination of a perpendicular magnetic recording channel detector and an LDPC code decoder. We examine the performance of channel iteration with joint LDPC code on perpendicular magnetic recording channel, and simplify the complexity of the message-passing detector algorithm.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF