• 제목/요약/키워드: detector

검색결과 6,175건 처리시간 0.034초

2개의 AMR 센서를 이용한 무선 차량 검지기에 대한 현장시험 및 평가 (Field Test and Evaluation for a Wireless Vehicle Detector with Two Anisotropic Magneto-Resistive Sensors)

  • 강문호
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.600-605
    • /
    • 2011
  • This paper shows field test and evaluation results for a wireless vehicle detector with anisotropic magneto-resistive (AMR) sensors. The detector consists of two AMR sensors and mechanical and electronic apparatuses. The AMR sensor senses disturbance of the earth magnetic field caused by a vehicle moving over the sensor and then produces an output indicative of the moving vehicle. In this paper, vehicle speeds are calculated by using two AMR sensors fixed on a board, with constant distance. To test and evaluate the accuracy of the detector in real traffic situations, the detector was installed on a local highway and vehicle speeds and volumes were measured both in a free running and a highly congested traffic. The measurements from the detector are compared with the reference measurements obtained from a traffic camera with the Mean Absolute Percentage Errors (MAPE), which has proved the usefulness of the detector in the field.

A Linear Photodiode Array Detector System for Multichannel Spectroscopic Applications

  • Kim, Hai-Dong;Han, Seung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권2호
    • /
    • pp.211-215
    • /
    • 1993
  • A multichannel optical detector system employing a self-scanning linear photodiode array has been developed. The photodiode array detector system is designed for various applications which require fast, multichannel detection of transient signals. The detector system consists of a controller which runs on an IBM personal computer and a detector head connected to the controller through a DB-15 cable. The entire scanning of 1024 detector elements is achieved in 20 ms. By using an on-board 16-bit counter/timer, the operational mode of the photodiode array detector is fully programmable by software. The design considerations and the performance of the photodiode array detector system is presented.

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권2호
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작 (Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver)

  • 이용주;김영완;박동철
    • 한국위성정보통신학회논문지
    • /
    • 제1권1호
    • /
    • pp.59-64
    • /
    • 2006
  • 본 논문에서는 직접 변환 방식인 six-port의 RF 출력 신호를 검파하고 요구 대역폭에서 입력 주파수 신호에 대한 진폭 및 위상 신호를 선형적으로 출력하는 광역 power detector를 설계 제작한다. Six-port 출력단에 접속되는 power detector는 높은 정합도를 갖고 반사파로 인한 Six-port 간 위상 불일치를 방지하고, 넓은 대역폭에서 낮은 VSWR을 유지하여야 하는 광역 특성을 갖는 power detector 설계가 필요하다. 광역 정합을 위하여 사용 주파수 대역에 따라 강제 정합과 다단 LC 정합 회로, 그리고 isolator를 사용한 낮은 VSWR 특성을 갖는 설계 방법을 비교 분석한다. 설계 제작된 power detector의 주파수 대역에 대한 동적 동작 영역(dynamic range) 성능을 측정하여 Six-port의 수신 전송 신호 검파기로 활용될 수 있는 타당성을 평가한다.

  • PDF

CNT/PMMA 복합막 검출기의 유기화합물 증기의 검출 특성 (Organic Compounds Vapor Detection Properties of MWCNT/PMMA Composite Film Detector)

  • 임영택;신백균;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제28권11호
    • /
    • pp.727-730
    • /
    • 2015
  • In this paper, we fabricated organic compounds detector using the MWCNT/PMMA (multi-walled carbon nanotube / polymethylmethacrylate) composite film. We used polymer film as a matrix material for the device framework, and introduced CNTs for reacting with the organic compounds resulting in changing electrical conductivity. Spray coating method was used to form the MWCNT/PMMA composite film detector, and pattern formation of the detector was done by shadow mask during the spray coating process. We investigated changes of electrical conductivity of the detector before and after the organic compounds exposure. Electrical conductivity of the detector tended to decrease after the exposure with various organic compounds such as acetone, tetrahydrofuran (THF), toluene, and dimethylformamide (DMF). Finally we conclude that organic compounds detection by the MWCNT/PMMA composite film detector was possible, and expect the feasibility of commercial MWCNT/PMMA composite film detector for various organic compounds.

A study of detector size effect using Monte Carlo simulation

  • Park, Kwang-Yl;Yi, Byong-Yong;Vahc, Young W.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.36-38
    • /
    • 2004
  • The detector size effect due to the spatial response of defectors is one critical source of inaccuracy in clinical dosimetry and has been a subject of numerous studies. Conventionally, the detector response kernel contains all of the influence that the detector size has on the measured beam profile. Various analytic models for this kernel have been proposed and studied in theoretical and experimental works. Here, we use a method to determine detector response kernel simply by using Monte Carlo simulation and convolution theory. Based on this numerical method and DOSIMETER, an EGS4 Monte Carlo code, the detector response for a Farmer type ion chamber embedded in water phantom is obtained. There exists characteristic difference in the simulated chamber readings between one with carbon graphite wall and the other with Acrylic wail. Using the obtained response and the convolution theory, we are planning to derive the detector response kernel numerically and remove detector size effect from measurements for 6MV, 10${\times}$l0cm2 and 0.5${\times}$10 cm2 photon beam.

  • PDF

Log-Normal Clutter 환경에서 차량용 UWB 단거리 레이더 수신기의 성능분석 (UWB Automobile Short Range Radar Receivers Performance In a Log-Normal Clutter Background)

  • 난데쉬;고석준
    • 대한전자공학회논문지TC
    • /
    • 제48권9호
    • /
    • pp.59-64
    • /
    • 2011
  • 초광대역 레이더는 높은 분해 능력으로 인해 단거리 차량용 레이더로 주목받고 있다. 차량으로부터 반사된 레이더 신호는 "clutter"라는 원하지 않는 반사 신호를 갖게 되어, 목표물을 검출하는데 어려움을 갖게 된다. 그러므로 목표물에서 반사된 신호로부터 보다 확실하게 검출하기 위하여 레이더 검출기를 개발할 필요가 있다. 본 논문에서는 log-normal clutter 환경에서 다양한 평균과 분산에서 최적인 검출기를 구하였다. 비동기 방식의 검출기로 자승 검출기와 선형 검출기, 로그 검출기 등을 분석하였다. 본 논문에서는 컴퓨터 시뮬레이션을 통해 검출기의 성능을 분석하여, 차량용 레이더로 최적인 검출기를 구하였다.

Peak Detector를 이용한 펄스방사선 선량 측정 (Pulse Radiation Dose Measurement using the Peak Detector)

  • 정상훈;이남호;오승찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1020-1022
    • /
    • 2013
  • 본 논문에서는 펄스방사선 선량 측정을 위한 Peak Detector를 설계하였다. 펄스방사선은 수ns ~ 수십ns의 초고속의 신호로 Peak 값을 측정하기 어렵다. Peak Detector는 센서에서 발생한 Peak 전압을 수ms 동안 유지하므로 ADC를 이용하여 데이터를 쉽게 측정할 수 있다. Peak Detector 시뮬레이션 결과 Peak 값을 1ms 이상 유지하는 것을 확인하였으며 펄스방사선 조사시험 결과 $1.95{\times}10^6rad/s$의 선량을 확인하였다.

  • PDF

비동기적 분산 시스템에서 결함허용 상호 배제 프로토콜의 설계 (Design of Fault-tolerant Mutual Exclusion Protocol in Asynchronous Distributed Systems)

  • 박성훈
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.182-189
    • /
    • 2010
  • 본 논문에서는 비동기적 분산시스템에서 고장 추적 장치를 이용한 상호배제의 문제를 서술하고 이러한 문제를 해결하는 가장 약한 고장 추적 장치를 결정하고자 한다. 이를 위해서 $M^*$라고 정의한 modal failure detector star 고장 추적 장치를 정의하고 $M^*$를 이용해서 상호배제 문제는 비동기적 분산 시스템에서 해결 가능함을 보인다. $M^*$는 perfect failure detector P보다 확실히 약하며 eventually perfect failure detector ◇P보다는 강한 고장추적 장치이다. 본 논문에서는 어떤 환경 안에서 이러한 문제가 해결 가능함을 보인다.