• Title/Summary/Keyword: detection voltage

Search Result 918, Processing Time 0.027 seconds

An Improvement in Synchronously Rotating Reference Frame-Based Voltage Sag Detection under Distorted Grid Voltages

  • Sillapawicharn, Yutthachai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1283-1295
    • /
    • 2013
  • This study proposed an improvement in synchronously rotating reference frame-based voltage sag detection under distorted grid voltages. In the past, the conventional synchronously rotating reference frame (CSRRF)-based voltage sag detection was generally used in the voltage sag compensation applications. Its disadvantage is a long delay of detection time. The modified synchronously rotating reference frame (MSRRF)-based voltage sag detection is able to detect the voltage sag with only a short delay in detection time. However, its operation under distorted grid voltage conditions is unavailable. This paper proposed the improvement of modified synchronously rotating reference frame (IMSRRF)-based voltage sag detection for use in distorted grid voltages with very fast operation of voltage sag detection. The operation of the proposed voltage sag detections is investigated via simulations and experimentations to verify the performance of the IMSRRF-based voltage sag detection.

A Study on the Low Voltage Detection Circuit (저전압 감지회로에 관한 연구)

  • Kim, Phil-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.676-680
    • /
    • 2016
  • This paper describes a low voltage detection circuit used in the semiconductor chips. The circuit was composed of a detection part of the CMOS structure as three stages and two inverters. The output of the low voltage detection circuit become to 'high' from 'low', when the power supply voltage falls below 80%. When the power supply voltage is 5 V, it was detected at 4 V point. The proposed low voltage detection circuit can be easily applied only by changing the resister and the capacitor without structural change in a wide range of power supply voltage.

Three-Phase PWM-Switched Autotransformer Voltage-Sag Compensator Based on Phase Angle Analysis

  • Mansor, Muhamad;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • Many voltage sag compensators have been introduced, including the traditional dynamic voltage restorer (DVR), which requires an energy storage device but is inadequate for compensating deep and long-duration voltage sags. The AC-AC sag compensators introduced next do not require a storage device and they are capable of compensating voltage sags. This type of compensator needs an AC-AC converter to regulate the output voltage. Presented in this paper is a three-phase PWM-switched autotransformer voltage sag compensator based on an AC-AC converter that uses a proposed detection technique and PWM voltage control as a controller. Its effectiveness and capability in instantly detecting and compensating voltage sags were verified via MATLAB/Simulink simulations and further investigated through a laboratory prototype developed with a TMS320F2812 DSP as the main controller.

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

Implementation of a Non-Linear Adaptive Filter Based Sag Detection Method for Dynamic Voltage Restorers under Unbalanced Fault Conditions

  • Cuma, M. Ugras;Teke, Ahmet;Meral, M. Emin;Bayindir, K. Cagatay;Tumay, Mehmet
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.304-312
    • /
    • 2013
  • The most common power quality problems in distribution systems are related to unbalanced voltage sags. Voltage sags must be detected quickly and corrected in a minimum amount of time. One of the most widely used methods for sag detection is based on the d-q transformation. This method has the disadvantage of missing the detection of unbalanced faults, because this method uses a voltage sag level signal obtained from the average of 3 phases for sag detection. In this paper, an adaptive filter sag detection method is proposed for Dynamic Voltage Restorers (DVR) under unbalanced fault conditions. The proposed DVR controller is able to detect balanced, unbalanced and single phase voltage sags. A novel reference voltage generation method is also presented. To validate the proposed control methods, a 3-phase DSP controlling a DVR prototype with a power rating of 1.5-kVA has been developed. Finally, experimental results are presented to verify the performance of the proposed control methods.

An Anomaly Detection Algorithm for Cathode Voltage of Aluminum Electrolytic Cell

  • Cao, Danyang;Ma, Yanhong;Duan, Lina
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1392-1405
    • /
    • 2019
  • The cathode voltage of aluminum electrolytic cell is relatively stable under normal conditions and fluctuates greatly when it has an anomaly. In order to detect the abnormal range of cathode voltage, an anomaly detection algorithm based on sliding window was proposed. The algorithm combines the time series segmentation linear representation method and the k-nearest neighbor local anomaly detection algorithm, which is more efficient than the direct detection of the original sequence. The algorithm first segments the cathode voltage time series, then calculates the length, the slope, and the mean of each line segment pattern, and maps them into a set of spatial objects. And then the local anomaly detection algorithm is used to detect abnormal patterns according to the local anomaly factor and the pattern length. The experimental results showed that the algorithm can effectively detect the abnormal range of cathode voltage.

Switching Signal Patterns to Prevent Short Circuit of AC Choppers (교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴)

  • Jang, Do-Hyeon;Yeon, Jae-Eul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage (입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.

Numerical estimation on balance coefficients of central difference averaging method for quench detection of the KSTAR PF coils

  • Kim, Jinsub;An, Seok Chan;Ko, Tae Kuk;Chu, Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.25-29
    • /
    • 2016
  • A quench detection system of KSTAR Poloidal Field (PF) coils is inevitable for stable operation because normal zone generates overheating during quench occurrence. Recently, new voltage quench detection method, combination of Central Difference Averaging (CDA) and Mutual Inductance Compensation (MIK) for compensating mutual inductive voltage more effectively than conventional voltage detection method, has been suggested and studied. For better performance of mutual induction cancellation by adjacent coils of CDA+MIK method for KSTAR coil system, balance coefficients of CDA must be estimated and adjusted preferentially. In this paper, the balance coefficients of CDA for KSTAR PF coils were numerically estimated. The estimated result was adopted and tested by using simulation. The CDA method adopting balance coefficients effectively eliminated mutual inductive voltage, and also it is expected to improve performance of CDA+MIK method for quench detection of KSTAR PF coils.