• Title/Summary/Keyword: detection of antibody

Search Result 612, Processing Time 0.031 seconds

Detection of Influenza A Virus by Interdigitated Nanogap Devices

  • Park, Jimin;Park, Dae Keun;Lee, Cho Yeon;Kang, Aeyeon;Yun, Wan Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.419-419
    • /
    • 2014
  • Interdigitated nanogap device (IND) is an attractive tool for biomolecular detection due to its huge on-off signal ratio, great tolerance to the variation in biochemical environment, and relatively simple implementation processes. Here, we report on the IND-based detection of Influneza A virus by sandwich immunoassay. The INEs were fabricated by photo lithography followed by the in-house chemical lithographic technique for the narrowing the initial gap distance. The surface of the silicon oxide between the two gold electrodes was chemically modified to immobilize primary antibodies for the immuno-specific interaction with the influenza A virus antigen. After immersing the functionalized-IND into the sample solution containing the influenza A virus, the device was exposed to the secondary antibody conjugated Au nanoparticles (Au NPs). The INDs showed a huge jump in the electric conductance when the sample solution contained the influenza A virus of the concentration as low as 10 ng/mL. We hope that this IND-based sensing can be applied to the development of simple and reliable diagnostic means of influenza viruses.

  • PDF

Detection of Carp Vitellogenin with Piezoelectric Immunosensor (압전류적 면역센서에 의한 잉어 Vitellogenin 검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Woo-Yeon
    • Applied Biological Chemistry
    • /
    • v.49 no.3
    • /
    • pp.254-258
    • /
    • 2006
  • Vitellogenin has been known as a potent biomarker protein for the estrogenic activity in fish exposed to endocrine disruptors. In this study, a piezoelectric immunosensor making use of an anticarp vitellogenin antibody and an AT-cut quartz crystal microbalance as the biological component and transducer was prepared, followed by its application to the analysis of carp vitellogenin as follows. Antibody immobilization was conducted by chemisorption of a thiolated antibody with a heterobifunctional thiolation cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. The reaction buffer for the immunosensor system was optimized as 0.1 M sodium phosphate (pH 7.4). Concentration-dependent sensor responses were obtained in the vitellogenin concentrations ranging from 0.4864 to 486.4000 nM, with a linear correlation between vitellogenin concentration and frequency shift in double-logarithmic scale. The limit of detection of the immunosensor for carp vitellogenin was presumed as 0.4864 nM.

Enzyme-linked Immunosorbent Assay for the Detection of Hen's Egg Proteins in Processed Foods

  • Shon, Dong-Hwa;Kim, Hyun-Jung;Kim, Soo-Ho;Kwak, Bo-Yeon
    • Food Science of Animal Resources
    • /
    • v.30 no.1
    • /
    • pp.36-41
    • /
    • 2010
  • The Hen's egg is widely used in many processed foods as an ingredient and is one of the most prevalent food allergens in children. To detect egg proteins in processed foods, we developed a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using an anti-ovomucoid (OM) antibody, which was produced by immunization of rabbits with OM, the most heat-stable component of the egg proteins. The detection limit of this quantitative assay system was 30 ng/mL. Cross-reactivity of the anti-OM antibody toward OM, ovalbumin, skim milk, casein, whey protein isolate, and isolated soy protein was 100, 0.4, 0.2, 0.04, 0, and 0%, respectively. In the spike test of egg white powder in milk replacer, commercial sausage, and in-house sausage, the assay recoveries ($mean{\pm}SD$) were $129{\pm}13.7%$, $73.9{\pm}12.5%$, and $65.5{\pm}13.6%$, respectively. When egg white in a commercial crab meat analog and sausage was determined by ciELISA, the assay recovery was found to be 108% and 127%, respectively. The combined results of this study indicate that this novel ciELISA for OM detection could be applied for the quantification of hen's egg proteins in processed foods.

Investigation of Red Cell Antiobody Screening Tests Gyeonggi Areas (경기일부지역의 적혈구 항체선별검사의 실태조사)

  • Kim, Dai-Joong;Sung, Hyun-Ho;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.1
    • /
    • pp.36-40
    • /
    • 2016
  • Red blood cell (RBC) alloimmunization results from genetic disparity of RBC antigens between donor and recipients. The discrepancy of RBC antibody screening test occurs when the results of red cell tests do not agree with those of the serum test. In order to select the proper blood units for transfusion, clarification of the cause of discrepancies is essential. The RBC antibody screening test is an easy, quick, and reliable method for detection of clinically significant antibodies. Antibody screening and identification is recommended prior to transfusion to determine whether there is blood group incompatibility. We reported that phenotyping for E, D, M, E+c, and C+e antibody screening test should be extended. Therefore, these results indicate that anti-D and anti-E alloantibodies were major risk factors for haemolytic disease of the newborn or delayed haemolytic transfusion reactions in this study population. We suggested that its antibody screening be adapted to blood safety interventions. Targeted screening of selected recipients at risk offers less value than universal antibody screening, and more research is needed to determine the real incidence of this national condition.

Flatfish Vitellogenin Detection Using Optical Waveguide Lightmode Spectroscopy-based Immunosensor

  • Kim, Nam-Soo;Ryu, Hyung-Seok;Kim, Woo-Yeon
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1445-1451
    • /
    • 2007
  • A sensitive optical waveguide lightmode spectroscopy-based immunosensor was developed to detect vitellogenin in seawater flatfish (Paralichthys olivaceus). For this purpose, anion-exchange column chromatography with DE-52 resin was used to purify flatfish vitellogenin from flatfish serum containing vitellogenin that had been induced using an intraperitoneal $17{\beta}$-estradiol injection. The anti-flatfish vitellogenin antibody used as the biological component of the above immunosensor was prepared using the purified flatfish vitellogenin. The change in the incoupling angle according to the complexation between the flatfish vitellogenin and its antibody, immobilized over an optical grating coupler sensor chip, was measured to calculate the sensor response. The immunosensor was quite specific to flatfish vitellogenin binding, based on no sensor response in the case of bovine serum albumin immobilization. When plotted using double-logarithmic scales, the sensor responses increased linearly in flatfish vitellogenin concentrations of 0.00675-67.5 nM, with a detection limit of 0.0675 nM. The reusability during seven repetitive measurements was reasonably fair for the preliminary screening of flatfish vitellogenin.

Survey on Antibodies Against Bovine Leukemia Virus in Chung Buk Province (충청북도 소 백혈병 항체 조사 연구)

  • 최해연;정운선;유기조;오홍세
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 1992
  • A serological survey was carried out for the detection of antibody of Bovine Leukemia Virus (BLV) in nothern parts of Chung Buk area. The results were summarized as followed. 1. The overall positive rate was revealed as high as 15% with 48 positive cases out of 319 heads examined. 2. According to age, cattle of 4 to 7 ages showed relatively higher positive rate of 15% than other ages. 3. Seasonal differences of positive rate were not recognized. 4. BLV antibody titer of scales of cattles that from 5 to 15 heads farm were the highest. 5. With the result of blood test that of BLV positive cattle, the number of WBC was slightly Increased, but other records were normal.

  • PDF

Production of Monoclonal Antibody to the Infective Stage of Cryptosporidium Infection in AIDS Patients

  • Cho, Myung-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.7 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • Cryptosporidium parvum has been recognized as a significant cause of life-threatening diarrhea in Acquired ImmunoDeficiency Syndrome (AIDS) patients. Clinical diagnosis of cryptosporidial infections has been primarily based on the detection of infective stage, oocysts, in stools. Anti-Cryptosporidium oocyst monoclonal antibody (mAb), IgG2a, recognizing an antigen of 97 kDa was generated to be used for diagnosis of Cryptosporidium infection in AIDS patients using an immunofluorecence. It appeared to react with the surface antigens. Transmission electron micrographs of the infective stage of Cryptosporidium recognized by this mAb demonstrated sporolulated oocysts, which measure $4~6{\mu}m$, and sporozoites excysting from oocysts.

  • PDF

Studies on Enzyme-Linked Immunosorbent Assay(ELISA) for Detection of antibody to Mycoplasma hyopneumoniae (돼지의 유행성폐렴 원인균(Mycoplasma hyopneumoniae)에 대한 항체가 분포도 조사)

  • 어용준;육동현;이재문;김윤기;이정학
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 1999
  • Mycoplasmal pneumonia of swine(MPS) cause by Mycoplasma hyopneumoniae has been recognized as a serious impediment to swine production due to chronic respiratory disorder which result in the weight loss and decreased feed conversion. The disease causes a great economic losses in pig industry by characterizing with high morbidity, low mortality, growth retardation and low feed efficiency. The present study was conducted to investigate the titers of antibody against M hyopneumoniae from the regional and seasonal groups of the slaughtered pigs by enzyme-linked immunosorbent assay(ELISA). The result have shown that the average seropositive rate of M hyopneumoniae infection was 84.6% . The regional seropositive rate in Korea showed 87.4% in Kyonggj, 83.4n in Kangwon, 89.2% in Chungnam and 77.6% in Chungbuk area, respectively. Also the seasonal seropositive rate was appeared as 78.6% in spring,90.1% in summer, 76.9% in autumn and 83.8% in winter, respectively.

  • PDF

Studies on porcine parvovirus inactivated vaccine and titration of serum neutralizing antibody (돼지 parvovirus불활화(不活化) vaccine 및 중화항체가측정(中和抗體價測定)에 관한 연구(硏究))

  • Kwon, Hyock-jin;Yeh, Jae-gil;Lee, Chang-koo
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.2
    • /
    • pp.355-359
    • /
    • 1988
  • A porcine parvovirus inactivated vaccine was prepared and inoculated to 7 piglets and also 8 guinea-pigs, and their serum antibodies were titrated. Twenty-two field serum samples of unvaccinated sows were also tested by SN and HI methods. It was observed that SN test was superior over HI test. Therefore, it is suggested that the SN test could well be used in the detection of serum antibody for PPV in vaccinated pigs.

  • PDF

Polymerase chain reaction for the detection of Toxoplasma gondii in the blood of cats (중합효소연쇄반응(PCR)을 이용한 고양이 혈액내에서의 Toxoplasma gondii 검출에 관한 연구)

  • Suh, Myung-deuk;Joo, Bo-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.6
    • /
    • pp.1151-1160
    • /
    • 1999
  • This study was conducted to detect the toxoplasma-specific DNA in peripheral blood collected from cats experimentally infected with Toxoplasma gondii (RH strain) and from domiciled cats by B1 gene-base polymerise chain reaction(PCR). The sensitivity of oligonucleotide primer, T-1 & T-2, designed from toxoplasma B1 gene amplification method was compared with parasite detection by mouse inoculation(MI). And also, latex agglutination test(LAT) and indirect fluorescent antibody test(IFAT) were conducted to detect the fluctuation of serum antibodies compared with the detection of toxoplasma by PCR and MI. Toxoplasma B1 gene PCR was shown consistently high sensitivity and the results obtained by PCR agreed completely with those from MI. All blood samples collected before infection with T gondii gave negative results by PCR and MI. Also, toxoplasma Bl gene PCR was not cross reaction with Neospora caninum DNA and normal cat leucocyte as controls. The toxoplasma-specific DNA was detected by PCR in blood of 5 cats experimentally infected with T gondii 6 days after infection and the detection of this specific-DNA was long lasted in blood for 64 days after infection. The detection of toxoplasma-specific DNA by PCR could be identified as few as 10 tachyzoites and the isolation of T gondii by MI could be isolated as few as 1 tachyzoite from tenfold serial dilution of T gondii with normal cat blood, respectively. In healthy domiciled cats, the toxoplasma-specific DNA and the parasite were detected and isolated in blood from 3 of 56(5.3%) cats by both PCR and MI, respectively. In the results of antibody test from the total 56 heads of healthy domiciled cats, the positive rates are 15(26.7%) by LAT and 19(33.9%) by IFAT. These results suggest that PCR detection of toxoplasma can be applied as a sensitive and specific diagnostic and research tool.

  • PDF