• Title/Summary/Keyword: detection of antibody

Search Result 609, Processing Time 0.031 seconds

DETECTION SYSTEM OF STREPTOCOCCUS MUTANS IN SALIVA USING MONOCLONAL ANTIBODY (Monoclonal Antibody를 이용한 Streptococcus mutans 검출 방법의 임상적 적용에 관한 연구)

  • Hong, Hi-Jung;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.522-530
    • /
    • 2009
  • The purpose of this study was to evaluate the clinical effectiveness of new streptococcus detection system which used monoclonal antibody against Streptococcus mutans. 92 children aged between 2 and 8 were involved in this experiment and their saliva samples were collected for testing. Streptococcus mutans were measured by both monoclonal antibody-based detecting system (Saliva-$check^{TM}$ Mutans) and dip slide detecting system($Dentocult^{TM}$-SM). The results showed that Saliva-$check^{TM}$ Mutans levels had a significant correlation with dfs rate of subjects and the two test kits, Saliva-$check^{TM}$ Mutans and $Dentocult^{TM}$-SM were shown to have a good correlation although they were based on different mechanism.

  • PDF

Studies on Analysis Method of T-2 Toxin by ELISA (ELISA에 의한 T-2 toxin의 분석법에 관한 연구)

  • 오유진;장성재;윤여표
    • Journal of Food Hygiene and Safety
    • /
    • v.3 no.2
    • /
    • pp.65-73
    • /
    • 1988
  • T-2 toxin is one of mycotoxins produced by fungi such as Fusarium spp. and possesses a potent cytotoxicity to eukaryotic cell. The contamination of mycotoxins in cereals and feedstuffs is one of the great concerns in health authorities. Therefore, the development of the specific, sensitive and simplified analysis method for T -2 toxin is required. During more than ten years, several chemical and biological analysis methods were proposed and applied for the detection and quantification of T-2 toxin. TLC, GLC-FID and GC-MS are widely employed, but these methods required numerous clean-up procedures before analysis, and the detection limit for T-2 toxin is more than 10 ppb. Biological analysis methods with dermal tissues and cultured cells are not specific to T-2 toxin, since T-2 toxin and other related derivatives possess a similar toxicological activity although their relative activity is different each otber. Based on tbe specific reaction between antibody and antigen, the authors tried to introduce the immunochemical methods for determination of T-2 toxin. The enzyme-linked immunosorbent assay method using monoclonal antibody for T-2 toxin was applied to analyse T-2 toxin. The detection limit of T-2 toxin by ELISA method was 0.1 ppb. The correlation between ELISA and GC-MS method on these samples was very high. ELISA method developed for the detection and quantification of T -2 toxin in this paper possesses simplicity, high sensitivity and specific for T-2 toxin. Furthermore, the ELISA method with T-2 toxin monoclonal antibody was an excellent tool for the screening of Fusarium spp. which was suspected to produce T-2 toxin.

  • PDF

Characterization of a Peptide Antibody Specific to the Adenylyl Cyclase-Associated Protein of Acanthamoeba castellanii

  • Kim, Min-Jeong;Lee, Hae-Ahm;Quan, Fu-Shi;Kong, Hyun-Hee;Moon, Eun-Kyung
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.1
    • /
    • pp.7-14
    • /
    • 2022
  • Acanthamoeba keratitis (AK) is a rare infectious disease and accurate diagnosis has remained arduous as clinical manifestations of AK were similar to keratitis of viral, bacterial, or fungal origins. In this study, we described the production of a polyclonal peptide antibody against the adenylyl cyclase-associated protein (ACAP) of A. castellanii, and evaluated its differential diagnostic potential. Enzyme-linked immunosorbent assay revealed high titers of A. castellanii-specific IgG and IgA antibodies being present in low dilutions of immunized rabbit serum. Western blot analysis revealed that the ACAP antibody specifically interacted with A. castellanii, while not interacting with human corneal epithelial (HCE) cells and other causes of keratitis such as Fusarium solani, Pseudomonas aeruginosa, and Staphylococcus aureus. Immunocytochemistry (ICC) results confirmed the specific detection of trophozoites and cysts of A. castellanii co-cultured with HCE cells. The ACAP antibody also specifically interacted with the trophozoites and cysts of 5 other Acanthamoeba species. These results indicate that the ACAP antibody of A. castellanii can specifically detect multiple AK-causing members belonging to the genus Acanthamoeba and may be useful for differentially diagnosing Acanthamoeba infections.

The prevalence of rubella antibodies in the women of childbearing age (서울시내 일개 대학병원에 내원한 가임 여성의 풍진항체 보유율)

  • Uhm Jin Woen
    • Journal of Korean Public Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.88-96
    • /
    • 1999
  • This study was conducted in May of 1996 to December of 1996 in order to investigate the status of rubella antibodies in the women of childbearing age. The subjects were 543 fertile women (Ages 21-42 years). ELISA method was used for the detection of rubella antibodies and then questionaire survey was performed to know about the variables of past history of rubella. past rubella immunization. parity and cognition. The results were as follows: 1. The Positive rate of rubella Ig G antibody in total subjects was $65.0\%$. The positive rate of rubella Ig G antibody was $72.2\%$ in 21-25 age group. $71.4\%$ in 26-30 age group. $54.5\%$ in 31-35 age group, $52.6\%$ in 36-42 age group. As age increased, the positive rate of rubella Ig G antibody was decreased. There was statistically significant difference by age group(P=0.00l). In the subjects with a history of rubella immunization, the positive rate of rubella IgG antibody was $81.8\%$, and in those with past history of rubella was $83.3\%$ of positive rate. 2, Cognition rate about rubella immunization showed $50.8\%$ in total subjects. and there was no significant difference between parity and cognition rate of rubella immunization(P=0.85l). observed a low positive rate of rubella IgG antibody as compaired with other studies. Therefore, to prevent congenital rubella infection, rubella immunization was needed for unmarried women.

  • PDF

Enhanced Performance of Immunoassays with Affinity-Purified Analyte-Enzyme Conjugates as Signal Generators

  • 백세환
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.5
    • /
    • pp.515-519
    • /
    • 1997
  • In a competitive enzyme immunoassay, the performance was tested with different analyte-enzyme conjugates (signal generators) in their binding constants to antibody. Analyte (progesterone)-enzyme (glucose oxidase; GO) conjugates were chemically synthesized and purified by using a gel column with an immobilized antibody to progesterone. In an elution range from the column, four peaks were detected by measuring total enzyme activities. Results from further analysis indicated that the first peak contained mainly unreacted GO while the next three peaks conjugated GO with progesterone. These three conjugate preparations were compared in dose-response curves along with the unpurified mixture. The purified conjugates showed higher detection capabilities than did the mixture. Especially, the preparation in the second peak next to the free GO peak improved the detection limit five times. This performance was comparable to that of a progesterone-horseradish peroxidase conjugate that has been identified to have one progesterone ligand.

Immunosignature: Serum Antibody Profiling for Cancer Diagnostics

  • Chapoval, Andrei I;Legutki, J Bart;Stafford, Philip;Trebukhov, Andrey V;Johnston, Stephen A;Shoikhet, Yakov N;Lazarev, Alexander F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4833-4837
    • /
    • 2015
  • Biomarkers for preclinical diagnosis of cancer are valuable tools for detection of malignant tumors at early stages in groups at risk and screening healthy people, as well as monitoring disease recurrence after treatment of cancer. However the complexity of the body's response to the pathological processes makes it virtually impossible to evaluate this response to the development of the disease using a single biomarker that is present in the serum at low concentrations. An alternative approach to standard biomarker analysis is called immunosignature. Instead of going after biomarkers themselves this approach rely on the analysis of the humoral immune response to molecular changes associated with the development of pathological processes. It is known that antibodies are produced in response to proteins expressed during cancer development. Accordingly, the changes in antibody repertoire associated with tumor growth can serve as biomarkers of cancer. Immunosignature is a highly sensitive method for antibody repertoire analysis utilizing high density peptide microarrays. In the present review we discuss modern methods for antibody detection, as well as describe the principles and applications of immunosignature in research and clinical practice.

Detection of Specific Antibodies Against Viral Hemorrhagic Septicemia Virus in Infected Olive Flounder Paralichthys olivaceus Using Enzyme-Linked Immunosorbent Assay (Enzyme-linked immunosorbent assay를 이용한 바이러스성 출혈성 패혈증 바이러스 감염 넙치(Paralichthys olivaceus)의 특이 항체반응 검사)

  • Hwang, Jee Youn;Jang, Jin Hyeon;Kim, Dong Jun;Kwon, Mun Gyeong;Seo, Jung Soo;Hwang, Seong Don;Son, Maeng-Hyun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.5
    • /
    • pp.547-552
    • /
    • 2017
  • The viral hemorrhagic septicemia virus (VHSV) has an extensive host range, and infects farmed and wild fish inhabiting both freshwater and marine ecosystems. Enzyme-linked immunosorbent assay (ELISA) is highly useful in diagnosing viral hemorrhagic septicemia. However, ELISA shows high, non-specific background reaction with fish antibodies. In this study, we optimized the antigen and antibody concentrations used for detecting specific antibodies in VHSV-infected olive flounder to reduce non-specific binding, and improve the sensitivity of ELISA. The results suggested that OD (optical Density) values were valid when ELISA was performed with $0.1{\mu}g/well$ of virus, involving blocking with blocking buffer (Roth, Roti-Block), 1:300-1:600 dilution with flounder antisera, and 1:1000 dilution with anti-flounder IgM and HRP-conjugated goat anti-mouse IgG for detecting the VHSV antibody in flounder sera. Furthermore, 11 different VHSV strains isolated in Korea from 2012 to 2016 were used to infect the fish. The results showed no correlation between viral pathogenicity and antibody production. This research is a basic study on the application of antibody detection in the diagnosis of viral hemorrhagic septicemia in the olive flounder.

Development of ELISA for detection of canine brucellosis (Canine brucellosis 검출을 위한 ELISA 진단법 확립)

  • Hur, Jin;Baek, Byeong-Kirl
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.159-166
    • /
    • 2011
  • This study was carried out to develope enzyme-linked immunosorbent assay (ELISA) for detection of canine brucellosis in dogs experimentally inoculated with Brucella abortus 1119-3 and B. canis RM666. Groups A, B and C of dogs (each group consisting of three dogs) were orally inoculated with approximately $5{\times}10^9$ colony-forming units of B. abortus and B. canis, and with sterile pyrogen-free PBS, respectively. The animals were monitored at regular intervals upto the 12th week post inoculation (PI) by standard tube agglutination test (STAT), plate agglutination test (PAT), Rose Bengal test (RBT), 2-mercaptoethanol rapid slide agglutination test (2ME-RSAT) and ELISA. The induced antibody titers in group A dogs were detected from the first week PI to the eighth week PI in STAT, PAT and RBT using the inactivated whole cells of B. abortus 1119-3 as antigens, while no sera in groups B and C dogs reacted with the antigens. In 2ME-RSAT using whole cells of B. canis M-strain as antigens, the induced antibody titers in group B dogs were observed at the second week PI and persisted for the 12th week PI, while sera of groups A and C dogs did not react with the whole cells. In ELISA using cytoplasmic fractions antigen of B. abortus 1119-3, the mean optical density of antibodies in groups A and B was detected from the first and second weeks PI, respectively, and persisted for 12th week PI, while sera of group C did not cross-react with the fractions antigen. However, in ELISA using the hot saline extracts of B. canis M- as an antigen, the induced antibody titers in only group B dogs were detected from second week PI and persisted for until the end of this study. These results indicate that the ELISA using B. abortus 1119-3 cytoplasmic fractions as antigens can be a good candidate for detection of brucellosis by B. abortus as well as B. canis in dogs.

Detection of a Thermal Stable-Soluble Protein (TSSP) as a Marker of Peanut Adulteration Using a Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay based on Monoclonal Antibodies

  • Sol-A Kim;Sazzad Hossen Toushik;Jeong-Eun Lee;Won-Bo Shim
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.9
    • /
    • pp.1170-1178
    • /
    • 2023
  • Food allergy represents a severe problem for many societies, including sensitive populations, academies, health authorities, and the food industry. Peanut allergy occupies a special place in the food allergy spectrum. To prevent consumption by consumers suffering from a peanut allergy, a rapid and sensitive detection method is essential to identify unintended peanut adulteration in processed foods. In this study, we produced four monoclonal antibodies (MAbs; RO 3A1-12, PB 4C12-10, PB 5F9-23, and PB 6G4-30) specific to thermo-stable and soluble proteins (TSSPs) of peanut and developed an enzyme-linked immunosorbent assay (ELISA) based on the MAbs. Among them, PB 5F9-23 MAb was firmly bound to Ara h 1, and other MAbs strongly reacted to Ara h 3 in the Western blot analysis. An antibody cocktail solution of the MAbs was used to enhance the sensitivity of an indirect ELISA, and the limit of detection of the indirect ELISA based on the antibody cocktail solution was 1 ng/ml and improved compared to the indirect ELISA based on the single MAb (11 ng/ml). The cross-reaction analysis revealed the high specificity of developed MAbs to peanut TSSPs without cross-reaction to other food allergens, including nuts. Subsequently, analyzing processed foods by indirect ELISA, all foods labeled as containing peanuts in the product description were confirmed to be positive. The results indicate that the developed antibodies exhibit high specificity and sensitivity to peanuts and can be used as bio-receptors in immunoassays or biosensors to detect intentional or unintentional adulteration of peanuts in processed foods, particularly heat-processed foods.