• Title/Summary/Keyword: detection circuit

Search Result 696, Processing Time 0.032 seconds

Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection (역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

Design and Implementation of 40 Gb/s Clock Recovery Module Using a Phase-Locked Loop with hold function (유지 기능을 가지는 위상고정 루프를 이용한 40 Gb/s 클락 복원 모듈 설계 및 구현)

  • Park, Hyun;Woo, Dong-Sik;Kim, Jin-Joog;Lim, Sang-Kyu;Kim, Kang-Wook
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.191-196
    • /
    • 2005
  • A low-cost, high-performance 40 Gb/s clock recovery module using a phase-locked loop(PLL) for a 40 Gb/s optical receiver has been designed and implemented. It consists of a clock recovery circuit, a RF mixer and frequency discriminator for phase/frequency detection, a DR-VCO, a phase shifter, and a hold circuit. The recovered 40 GHz clock is synchronized with a stable 10 GHz DR-VCO. The clock stability and jitter characteristics of the implemented PLL-based clock recovery module has shown to significantly improve the performance of the conventional open-loop type clock recovery module with DR filter. The measured peak-to-peak RMS jitter is about 230 fs. When input signal is dropped, the 40 GHz clock is generated continuously by hold circuit. The implemented clock recovery module can be used as a low-cost and high-performance receiver module for 40 Gb/s commercial optical network.

  • PDF

A study on efficient operation of DC track circuit (DC 궤도회로의 효율적인 운용방법에 대한 연구)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.70-75
    • /
    • 2014
  • A track circuit is a critical piece of equipment that allows the existence of the trains on the track to be detected. Train detection is very important for the signal safety equipment. It allows for the confirmation of a train's location, the locking of switch points, the coordination of safe distance between trains, and the advance notice of a train's arrival. Track circuits can be powered by AC or DC. The DC track circuits are usually used on non-electrified tracks. On these tracks, many signal errors can be caused by lightning or problems with the power source. These problems can also cause damages to the rectifiers which must be repaired or replaced, promptly. This issue is especially problematic in the summer because of the higher frequency of thunderstorms. Issues with track circuits also cause problems for other equipment, such as railroad crossings and switch points. This further disrupts the safe operation of trains. This study aims to enhance maintenance efficiency and improve safety by utilizing parallel operation and multiplexing of a DC track circuit as well as installing an external surge protector. The experimental results on the operation of the proposed method is also presented.

A Study on the Malfunction Prevention for Transponder of Record Type Fire Alarm System (R형 자탐설비의 중계기 오동작 방지 대책에 대한 연구)

  • Yoo, Jae Ick;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.54-59
    • /
    • 2014
  • The record type receivers that are operated in large industrial sites have strength in preventing fire. However, because of its long circuit lines and multiple detectors, the receivers are vulnerable to lightning, noise, and breakdown of equipments, resulting in malfunction. In case of malfunctioning of detection circuits of main protection areas, such as electrical room and server room, potential release of gaseous extinguisher agents may lead to property and life damage. In this paper, we present the results on the characteristics of the transponder that initiates the solenoid valves, with respect to various electromagnetic and lightning inflow conditions. Based on the measured data, we analyzed the systematic problems of the transponder. In order to prevent receiver malfunctions, a sequential circuit was configured with two additional transponders and a timer. The circuit was tested with a simulator with preference and delay circuit algorithms.

A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident (결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Modeling of IPMC (Ionic Polymer-Metal Composite) Sensor to Effectively Detect the Bending Angles of a Body

  • Park, Ki-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.375-381
    • /
    • 2011
  • Ionic polymer-metal composite(IPMC) consists of an ion conductive membrane plated by metallic electrodes on both surfaces. When it bends, a voltage is generated between two electrodes. Since IPMC is flexible and thin, it can be easily mounted on the various surfaces of a body. The present study investigates a sensor system using IPMC to effectively detect the bending angles applied on IPMC sensor. The paper evaluates several R and C circuit models that describe the physical composition of IPMC and selects the best model for the detection of angles. The circuit models implemented with a charge model describe the relationship between input bending angles and output voltages. The identification of R and C values was performed by minimizing the error between the real output voltages and the simulated output voltages from the circuit models of IPMC sensor. Then the output signal of a sensor was fed into the inverse model of the identified model to reproduce the bending angles. In order to support the validation of the model, the output voltages from an arbitrary bending motion were also applied to the selected inverse model, which successfully reproduced the arbitrary bending motion.

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • Song In Ho;Shin H. S.;Choi C. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.707-710
    • /
    • 2002
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute in Taejon to supply power with Korea Superconducting Tokamak Advanced Research (KSTAR) Neutral Beam Injection (NBI) system. NBI system requires fast cutoff of the power supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply and there are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply, Various results taken during the commissioning phase with a 100kW resistive load and NBI source are shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver and solutions are also presented.

  • PDF

Detection and Location of Open Circuit Fault by Space Search (Space Search에 의한 회로의 단선 결함을 발견 및 위치 검색법)

  • Han, Kyong-Ho;Kang, Sang-Won;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.43-49
    • /
    • 1995
  • In this paper a space search technique is used to detect and locate the faults of the circuit interconnections. The circuit interconnections are represented by the tree structure and the tree space is searched to detect and locate the open faults of the circuit interconnections. The breadth search is used to detect the open faults and reduce the space size. The depth search is used to locate the open faults.

  • PDF

An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

  • Nam, Sang-Ho;Kim, Yu-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1967-1971
    • /
    • 2012
  • A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg.

Fault Tolerant Operation of CHB Multilevel Inverters Based on the SVM Technique Using an Auxiliary Unit

  • Kumar, B. Hemanth;Lokhande, Makarand M.;Karasani, Raghavendra Reddy;Borghate, Vijay B.
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.56-69
    • /
    • 2018
  • In this paper, an improved Space Vector Modulation (SVM) based fault tolerant operation on a nine-level Cascaded H-Bridge (CHB) inverter with an additional backup circuit is proposed. Any type of fault in a power converter may result in a power interruption and productivity loss. Three different faults on H-bridge modules in all three phases based on the SVM approach are investigated with diagrams. Any fault in an inverter phase creates an unbalanced output voltage, which can lead to instability in the system. An additional auxiliary unit is connected in series to the three phase cascaded H-bridge circuit. With the help of this and the redundant switching states in SVM, the CHB inverter produces a balanced output with low harmonic distortion. This ensures high DC bus utilization under numerous fault conditions in three phases, which improves the system reliability. Simulation results are presented on three phase nine-level inverter with the automatic fault detection algorithm in the MATLAB/SIMULINK software tool, and experimental results are presented with DSP on five-level inverter to validate the practicality of the proposed SVM fault tolerance strategy on a CHB inverter with an auxiliary circuit.