• Title/Summary/Keyword: design forces

Search Result 2,246, Processing Time 0.035 seconds

Design Evaluation of Pickup Device Collecting Deep-Sea-Manganese Nodules (심해저 망간단괴 집광기 채집장치의 설계평가)

  • Choi, Jong-Soo;Lee, Tae-Hee;Hong, Sub;Sim, Jae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1998
  • Performance and efficiency of deep seabed collector is a primary factor for feasibility of commercial deep ocean mining. The efficiency of manganese nodules collector depends on vehicle mobility relative to undulating seafloor and is attributed pickup head to keep altitude and elevation of it against seafloor. For this reason, motion control of pickup head relative to the changing deep-sea topography and other disturbances is of particular importance in design of pickup device. The concept of design axiom is applied to a pickup device of hybrid type in order to evaluate the concept design. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pickup head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

The Comparison of the Stability of a Container Crane according to various Wind Load Design Codes (풍하중 설계 기준에 따른 컨테이너 크레인의 안정성 비교)

  • Lee Seong-Wook;Shim Jae-Joon;Han Dong-Seop;Han Geun-Jo;Kim Tae-Hyung
    • Journal of Navigation and Port Research
    • /
    • v.29 no.6 s.102
    • /
    • pp.561-566
    • /
    • 2005
  • This study was carried out to amlyze and compare the stability of a 50ton container crane according to various wind load design codes. The wind load was evaluated according to 'The Specification of Port Facilities and Equipments / Specification for the design of crane structures (KS A 1627)' and 'Load Criteria of Building Structures' effected by the ministry of construction & transportation And the uplift forces qf a container crane under this wind load were estimated by amlyzing reaction forces at each supporting point and compared each other. From this study, we noticed that the design wind velocity criteria need to be defined specifically when the wind load is evaluated to design a container crane. And we verified the necessity of the estimation of the uplift forces at each supporting point to analyze a structural stability of a container crane and the maximum compressive force in order to consider the stability of the ground foundation of the berth.

Evaluation of the Strength Required in Current Seismic Design Code (현행 내진설계 규준의 수평강도 요구에 대한 평가)

  • 한상환;오영훈;이리형
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-290
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, lateral strength required to maintain target ductility ratio was first calculated from nonlinear dynamic analysis of the single degree of freedom system. At the following step, base shear foeces specified in seismic design code compare with above results. If the base shear force required to maintain target ductility ratio was higher than the code specified one, the lack of required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of push-over analysis.

  • PDF

An Experimental Study on the Design Parameters of the Dashpot type MR fluid mount (대시포트형 MR유체 마운트의 설계 인자에 대한 실험적 고찰)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3567-3573
    • /
    • 2009
  • This research proposed a dashpot type mount design using MR fluids, and investigated experimentally the influence of the design parameters of the dashpot MR fluid mount, which affect the damping forces of the dashpot MR fluid mount. In order to observe the influence, the dashpot MR fluid mount which have the different effective length and the core structure is manufactured. The variations of the resistance forces according to different effective lengths of the magnetic pole of MR fluid mount, along which magnetic field is defined, was investigated. It was founded that the resistance forces from the MR mount decreased with increased input frequencies, while increased with increased applied electric current intensities. Nevertheless, there is no appreciable change in the resistance forces with respect to the effective length variations of the magnetic pole of MR fluid mount.

Influence of Rail Supporting Spacing of Railway Bridge Deck Ends on Bridge-Track Interaction Forces (교량-궤도 작용력에 대한 교량 단부에서의 레일지지점간격의 영향)

  • Choi, Jun-Hyeok
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.4
    • /
    • pp.245-250
    • /
    • 2014
  • This paper, as a study for the serviceability design of railway bridges with concrete track, presents the effects of design parameters of tracks and bridges on the forces acting on the rail supports of the track. To calculate the forces acting on the track, an unequal spacing discrete supported model with different spacing of rail supports was induced. Design parameters are the rail support spacing of expansion joints above abutments or piers of bridges, the distance from the support of a girder to the last rail support on the end of the girder, and the number of additional rail supports. The causes of the displacement of track are axial force, unit vertical displacement, and unit rotation. From the analysis, the maximum compressive force and the maximum uplifting force acting on the rail supports were determined and the effects of the rail support spacing on the forces acting on the track were presented.

Study on the Seepage Forces Acting on the Tunnel Face with the Consideration of Tunnel Advance Rate (터널 굴진율을 고려한 막장에서의 침투력에 관한 연구)

  • 남석우;이인모
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.221-228
    • /
    • 2002
  • The stability of a tunnel face is one of the most important factors in tunnel excavation. Especially, if a tunnel is located under groundwater level, groundwater may flow into the tunnel face and seepage forces acting on the tunnel face due to groundwater flow may affect seriously the stability of the tunnel face. Therefore, the seepage pressure at the tunnel face should be considered fir the proper design and safe construction of a tunnel. In this paper, the effect of tunnel advance rate on the seepage forces acting on the tunnel face was studied. The finite element program to analyze the groundwater flow around a tunnel with the consideration of tunnel advance rate was developed. Using the program, the parametric study for the effect of the tunnel advance rate and hydraulic characteristics of the ground on the seepage forces acting on the tunnel face was made. From this study, it was concluded that the tunnel advance rate must betaken into consideration as an additional parameter to assess the seepage forces at the tunnel face and a rational design methodology fer the assessment of support pressures required for maintaining the stability of the tunnel face was suggested for undetwater tunnels.

A Study on the Meaning Function of Symbol Design based on The Comic Dual Forces and The Five Elements (음양오행(陰陽五行) 사상에 의한 심볼디자인의 의미적용 가능성 연구)

  • 장은석;김재희
    • Archives of design research
    • /
    • v.12 no.2
    • /
    • pp.53-62
    • /
    • 1999
  • The modern is image age, and The visually expressed symbols have much influence on individuals or enterprises and have an effect on the variety of individual and the innovation of management. Espacially, the symbols carry on the axis composing total image. According to the reason of positive & negative five elements, this paper analysised and studied the meaning of symbol design which analysis the thoughtful, abstract and formal meaning. This is the most fundmental elements and principals and means the good symbol composed harmoniously the positive & negative five elements give good image. Namely, the symbols of the Eum & Yan which applied the philosophical reason of the Orient thought became good image. The lively elements of design composed the reason of Eum & Yang have effect on auspicious and upgrade one step to the dimension of symbol design. The purpose of this paper analysises and understands the meaning of symbol was composed the positive & negative five elements. In the point of view of modern design. the overlOOking elements of the symbol(line, form, space etc) reminded and established the new model which the new idea approached by the thought of the positive & negative five elements.

  • PDF

A Study on the Characteristics of High-Tension Bolted Joints' Behavior due to Surface Condition (표면상태에 따른 고장력볼트 마찰이음부의 거동특성에 관한 연구)

  • Cho, Sun Kyu;Hong, Sung Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.421-430
    • /
    • 1997
  • In this study, the static and the fatigue tests were performed with high tension bolted joints, of which the surfaces were spread with inorganic zinc-primer after shot-blast, and milling surface, and steel-natural surface, difference of friction surface condition were examined by comparing the esults of tests. From the result of synthetical investigation of this study. it is proper that using the torque management method in order to introduce design axial force to blots, and the provision of specifications that initial axial forces must be 110% of design axial forces is proper. Decreasing ratio of axial forces to initial force is proportional to common lorgarithms of time progress, it converge constant value after 20 hours, and decreasing ratio is little related to the roughness of friction surface. Sliding coefficient of milling, spreading inorganic zinc-primer, just producting is great in order and sliding forces are dependent on the applied axial forces, but if the applied axial forces are great, sliding coefficient become small by a loss of roughness. So it is confirmed that relation between the applied axial forces and the sliding forces are not proportional linearly. From the result of estimation on fatigue strength, all specimens satisfy the specifications with B-grade and milling surface is lower than the others about 14% in fatigue strength because in milling surface lose the function of friction-types joints at lower number of cycles. From the result of eximination for the distribution area of compressive force, friction area near to inside bolt is wider in the direction of stress than near to outside. It is guessed that this situation occurs because outside bolts firstly change from the friction connection to the bearing connection.

  • PDF

The Immediate Effects of Ankle Restriction Using an Elastic Band on Ground Reaction Force during a Golf Swing

  • Yi, Kyungock;Kim, OkJa
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.191-195
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the immediate effects of ankle restriction with an elastic band on ground reaction force during a golf swing. Method: There were five subjects who were teaching pros with an average golf score of 75. A force platform (9281B, Switzerland) was used. The independent variable was the presence of an elastic band. The dependent variables were three-dimensional ground reaction forces to analyze the transfer of momentum with the timing, control and coordination of the three forces. A paired t-test within subject repeated measure design was used via an SPSS 20.0. Results: Wearing an elastic band around one's ankles significantly makes shorter time differences between the moment of cross anterior / posterior forces and vertical force and median value of anterior / posterior forces during the backswing, between medial and lateral maximum and anterior / posterior force from the top of the back swing to the mid down swing, and creates an anterior / posterior maximum force. Conclusion: Wearing an elastic band around one's ankles affects control and coordination between three dimensional forces, and anterior force power according to each phase of the golf swing.

Approximation Method to Estimate Water Entry Impact Forces Acting on Light Weight Torpedo (경어뢰 입수 충격력의 근사화)

  • Chan-Ki Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.2
    • /
    • pp.77-87
    • /
    • 2000
  • The water entry forces acting on an air-dropped torpedo are of the restrictions on launch speed and launch altitude, because it could cause the structural damage to components of torpedo. Therefore, it is necessary to estimate the water entry forces with confidence according to launch conditions. In this study, an approximation method for water entry forces is presented, and the results using this approximation are compared with those of other numerical methods. The magnitude and duration of impact forces estimated by the present approximation agree with those of impact by the analysis of ideal or viscous flow. This method can give useful tools to select the launch in initial design stage.

  • PDF