• Title/Summary/Keyword: derivatization method

Search Result 192, Processing Time 0.019 seconds

Quantification of urea in serum by isotope dilution HPLC/MS (동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량)

  • Lee, Hwashim;Park, Sangryoul
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.271-277
    • /
    • 2005
  • Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is e end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed isotope dilution-liquid chromatography/mass spectrometry (ID-LC/MS) as a candidate primary method, in which $15^N_2$-urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization. 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provided low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an electrospray ionization (ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum certified reference materials (CRMs).

Analysis of formaldehyde using DNPH cartridge/LC-MS in the Ban-Woll.Shi-Hwa Industrial Complex (DNPH cartridge/LC-MS 방법에 의한 반월.시화산업단지의 폼알데하이드 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok;Kim In-Gu;Kim Woong-Soo;Kim Jong-Bo;Kim Tae-Hyun;Hwang Sun-Min;Nam Woo-Kyong
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.35-43
    • /
    • 2006
  • Formaldehyde is important because of their irritant and toxic properties, mutagenicity and carcinogenicity. In this study, liquid chromatography-mass spectrometry (LC-MS) is used for the analysis of formaldehyde after derivatization with 2,4-dinitrophenylhydrazine (DNPH) cartridge. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearity ($r^2$) was 0.9997 when analyte concentration ranges from 25 to $200{\mu}g/l$. The relative standard deviation (%RSD) was 1.25 % for concentration of $200{\mu}g/l$. The minimum detection limit (MDL) was 0.73 ppbv. It was shown that LC-MS method has a great potential for formaldehyde analysis. The results of formaldehyde from the survey of Ban-Woll and Shi-Hwa Industrial Complex samples, the highest level was 6.20, 3.93 ppb, respectively. The highest emission level of formaldehyde at chemical plants in the Ban-Woll' Shi-Hwa Industrial Complex was 5421.25 ppb.

Detection and Quantitation of Residual Antibiotics and Antibacterial Agents in Foods

  • Ryu, Jae-Chun;Seo, Ja-Won;Song, Yun-Seon;Park, Jong-Sei
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.3
    • /
    • pp.159-164
    • /
    • 1990
  • To detect and quantitation residual antibiotics and antibacterial agents in meats, we performed a biological assay employing the three microorganisms Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778 for the screening purpose and developed a Gas Chromatography-mass Spectrometry(GC/MS) analysis for the confirmation and quantiation. In the biological assay (paper disk method), three test solution are used depending on the character of the residual antibiotics and antibacterial agents, follow by a simple clean up procedure which includes homogenization with Mcilvaine buffer, defatting with includes homogenization with Mcilvaine buffer, defatting with hexane, extraction with chloroform, clean-up by Sep-Pak $C_{18}$ and Bakerbond SPE carboxylic acid column. The chloroform layer is used for the analysis of sulfa agents. macrolides antibiotics and antibacterial agents, Adsorbed materials in the Sep-Pak $C_{18}$ were also employed for th analysis of penicillins and tetracyclines. Effluents from the Sep-Pak $C_{18}$ were cleaned-up one more by Bakerbond 10 SPE COOH column and employed for the analysis of aminoglycosides. In the instrumental analysis by using the GC/MSD, residual antibiotics and antibacterial agent were quantitated by selected ion monitoring (SIM) mode after derivatization. A simultaneous analysis of six residual antibiotic and antibacterial agent such as oxytetracycline, penicillin, ampicillin, choliraphenicol and thiamphenicol was developed with simple cleanup procedures revealing good recovery and reproducibility. Also, simultaneous detection of macrolides antibiotics such as erythromycin, spiramycin, and oleandomycin was developed after acid hydrolysis due to their large molecular structures. Because of the high reproducibility and selectivity of these two methods, it is very desirable that the combination of the two methods be used in the bioassay for the screening of residual antibiotics and antibacterial agent and that GC/MSD analysis be used for the confirmation and quantitation.

  • PDF

Determination of Semicarbazide in PVC Gaskets of Food Bottle Cap and Foods (식품병마개 PVC gasket과 식품에 함유된 semicarbazide의 분석)

  • Park, Sang-Wook;Lee, Kwang-Ho;Kwak, In-Shin;Jeon, Dae-Hoon;Lee, Si-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.334-338
    • /
    • 2005
  • Method was developed to efficiently analyze semicarbazide (SEM) in foods. Although SEM is produced by thermal decomposition of blowing agent azodicarbonamide, it is too small to be activated by ultraviolet light or fluorescence. When 2-nitrobenzaldehyde semicarbazone, derivatization of SEM, was analyzed by HPLC with triple column system, coefficient correlation over 0.9997 and detection limit of 0.48 ng/g were observed. SEM level in commercial bottle cap gasket was 812.20-5771.30ng/g. Recoveries for SEM in food and PVC gasket were 83.45-97.33% and 92.12-98.71%, respectively. SEM level in plastic seals of press twist-off metal lids was ND-5771.330ng/g.

Anti-Proliferative Activity of Naturally Occurring Flavonoids on Cultured Human Tumor Cell Lines (천연 유리 Flavonoid 화합물들의 암세포성장 저해효과)

  • Kim, Jung-Sook;Choi, Yeon-Hee;Seo, Jee-Hee;Lee, Jung-Won;Kim, Seong-Kie;Choi, Sang-Un;Kang, Jong-Seong;Kim, Young-Kyoon;Kim, Sung-Hoon;Kim, Young-Sup;Ryu, Shi-Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.35 no.2 s.137
    • /
    • pp.164-170
    • /
    • 2004
  • The flavonoids are a very large and important group of polyphenolic natural products, which are united by their derivatization from the heterocycle, flavone. They are distributed in higher plants and occur widely in the fruits and vegetables that make up the human diet. They exhibit a wide range of biological properties, including antitumor, antiinflammatory, hepatoprotective, antimicrobial, insecticidal and estrogenic activities. They are also major components of many plant drugs and it is possible that they contribute to the curative properties. For the purpose of developing anticancer agent of natural origin, we have evaluated forty four kinds of naturally occurring flavonoids for the inhibitory activity upon the proliferation of cultured human tumor cells such as A549 (non small cell lung), SK-OV-3 (ovary), SK-MEL-2 (melanoma), XF498 (central nerve system) and HCT-15 (colon) in vitro.

Determination of 3-Monochloro-1, 2-propanediol in Acid Hydrolyzed Soysauce(Ganjang) by Gas-Chromatography with Electron Capture Detector (Gas Chromatography-Electron Capture Detector를 이용한 산분해간장중의 3-Monochloro-1, 2-propanediol 분석법에 관한 연구)

  • 최종동;문귀임;오현숙;김동술
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.1
    • /
    • pp.61-65
    • /
    • 2001
  • To investigate the optimum condition of 3-monochloro-1, 2-propanediol(MCPD) analysis, gas chromatography with electron capture detector was used. Determination of MCPD derivatized with phenylboric acid was more effective than that of underivatized MCPD. In derivatization of MCPD with phenyl boric acid, there were no significantly different between boiling for 2min at 9$0^{\circ}C$ and vortexing for 5min at room temperature. Extrelut column was suitable for extraction of MCPD diluted in 20% NaCl solution and recovery rates were higher than direct extraction of MCPD with ethyl acetate. But, the method of direct extraction of MCPD with ethyl acetate was useful for rapid ants qualitative analysis. The sample extracted in soysauce(ganjang) was derivatized with phenylboric acid and analyzed by gas chromatography-mass selective detector. That was confirmed as MCPD-phenylboronate.

  • PDF

Determination of Histamine by Reverse-Phase High Performance Liquid Chromatography with Fluorescence Detection (형광검출 역상 액체크로마토그래피에 의한 Histamine의 정량)

  • Ryu, Hee-Chun;Kim, Hyung-Ryong;Kim, Sang-Hyun;Kim, Dae-Ki;Lee, Young-Mi;Kim, Hyung-Min;An, Nyeon-Hyoung;Shin, Tae-Yong
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.198-202
    • /
    • 1996
  • A rapid and simple method for the determination of histamine by reverse-phase high performance liquid chromatography with fluorescence detection was established. 9-Fluorenylmethyl chloroformate(FMOC) was used as fluorescent derivative reagent. The optimum conditions for the derivatization such as pH, reaction time and the concentration of FMOC were investigated. Linearity of calibration curve was obtained between $0.1{\mu}g/ml$ and $0.5{\mu}g/ml$(r=0.992) and the limit of detection was $0.01{\mu}g/ml$.

  • PDF

The study on the analysis of α-naphthylamine in urine (요중 알파나프틸아민 분석에 관한 연구)

  • kim, Choon Sung;Roh, Jae Hoon;Bae, Mun Joo;Kim, Chi Nyon;Lim, Nam Gu;Won, Jong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

Fingerprint of Marker Substances in Gami-Honghwa-Tang(KH-19) by HPLC-DAD (High Performance Liquid Chromatography-Diode Array Detector(HPLC-DAD)에 의한 가미홍화탕 (KH-19)의 지문 분석)

  • Yu Young-Beob;Yoon Yoo-Sik;Cho Gi-Ho
    • The Journal of Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.45-54
    • /
    • 2004
  • Objectives : This study was aimed to evaluate marker substances in Gami-Honghwa-Tang (KH-19) by high performance liquid chromatography-photodiode array detector (HPLC-DAD). Gami-Honghwa-Tang is composed of nine crude herbs, Rehmanniae Radix Preparata, Angelicae Gigantis Radix, Cnidii Rhizoma, Paeoniae Radix, Corni Fructus, Moutan Cortex Radicis, Lycii Fructus, Carthami Flos and Glycyrrhizae Radix. Methods : The separation was performed on an Aquasil C18 (4.6×250mm) column by gradient elution with 0.05% TFA in H2O - 0.05% TFA in acetonitrile (0 min 100:0, 20 min 90:10, 40 min 70:30, 60 min 50:50, 80 min 0:100, 90 min 100:0) as the mobile phase at a flow-rate of 1.0 ml/min with detection at 190-800nm. Also we examined the contents for bacteria, pesticide residue and harmful heavy metals. Results : HPLC-DAD was employed to determine the quantities and the qualities of several marker substances such as 5­hydroxymethyl-2-furaldehyde (5-HMF), paeonol, loganin, paeoniflorin, glycyrrhizin, and decursin in the KH-19. There were no bacterial contents, pesticide residues, or harmful heavy metals. Conclusions : We suggest these results could be a useful evidence for quality control of KH-19. This method permits fingerprints of selected individual marker substances from herbal prescriptions without derivatization, multiple purification steps, or lengthy separation times.

  • PDF

The effect of relative humidity on the performance of DNPH-cartridge sampling for odorous aldehydes (악취성 Carbonyl 화합물의 카트리지 채취 분석: 습도가 채취효율에 미치는 영향)

  • Lee, Min-Hee;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.50-59
    • /
    • 2012
  • In this study, the effect of humidity change on DNPH cartridge sampling efficiency for carbonyl compounds (CCs) has been investigated. For this analysis, gaseous standard of 6 different CCs (formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA), and valeraldehyde (VA)) was calibrated after derivatization with three types of DNPH cartridge products. Their calibration results derived at RH values between 0 and 80% were then compared against liquid phase standards. If the results of our analysis are compared by the RH values between 20 and 80%, the effect of RH can be distinguished between light and heavy CCs. For lighter CCs (like FA and AA), there was no significant change. However, for the ones heavier than PA, there was fairly noticeable increase in relative recovery ratio in RH value between 20 and 80%. Such patterns are seen consistently from all three DNPH products tested for comparison. The results of our analysis suggest that proper correction for RH change may be needed for heavier CCs by the cartridge method.