• Title/Summary/Keyword: depth level

Search Result 2,644, Processing Time 0.023 seconds

Clinical Evaluation of Tooth Mobility Following Root Planing and Flap Operation (치근활택술과 치은박리소파술 후 치아동요도 변화에 관한 연구)

  • Pang, Eun-Kyoung;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.893-914
    • /
    • 1999
  • Tooth mobility may be the decisive factor that determines whether dental treatment of any kind is undertaken. Although tooth mobility in isolation says little in itself, the finding of increased tooth mobility is of both diagnostic and prognostic importance. Only the detection of an increase or decrease in mobility makes an evaluation possible. Thus prior to treatment, we must understand the pathologic process causing the observed the tooth mobility and decide whether the pattern and degree of observed tooth mobility is reversible or irreversible. And then it must be decided whether retention and treatment or extraction and replacement. The purpose of this study was to compare tooth mobility at different time period during root planing and flap operation and to relate changes in mobility to each treatment method. Twenty-one patients (287 teeth) with chronic adult periodontitis were treated with root planing(control group) and flap operation(experimental group), and each group was divided 3 subgroups based upon initial probing pocket depth (1-3mm, 4-6mm, 7mm and more). Tooth mobility was measured with $Periotest^{(R)}$ at the day of operation, 4 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 8 weeks, 12 weeks after each treatment. Tooth mobility, attachment loss, radiographic bone loss, and bleeding on probing were measured at the day of operation, 4 weeks, 8 weeks and 12 weeks after treatment. 1. In group initial probing depth was 1-3mm, tooth mobility had no significant difference after root planing and flap operation. 2 . In group initial probing depth was 4-6mm, 7mm and more, tooth mobility had decreased in 12 weeks after root planing(p<0.01). And the mobility had increased after flap operation(p<0.01) and was at peak in 1 week, and decreased at initial level in 4 weeks, below the initial level in 12 weeks(p<0.01). 3. In 1 week, significant difference in tooth mobility between control and experimental group was found(p<0.01) but, in 12 weeks no difference between two groups was found. 4. Change of immediate tooth mobility after treatment was more larger in deep pocket than in shallow one. In group with the same probing pocket depth, the change of tooth mobility in molar group was greater than that of premolar group. 5. Tooth mobility before treatment was more strongly correlated with radiographic bone loss (r=0.5325) than probing depth, attachment loss and bleeding on probing, in 12 weeks after treatment, was more strongly correlated with attachment loss($r^2$=0.4761) than probing depth and bleeding on probing. Evaluation of the treatment effect and the prognosis after root planing and flap operation were meaningful on tooth initial probing depth 4mm and more. After flap operation, evaluation of the prognosis should be performed at least in 4 weeks and in 12 weeks after treatment, no difference in tooth mobility between two groups was observed. Radiographic bone loss and attachment loss were good clinical indicators to evaluate tooth mobility.

  • PDF

Effects of In-depth Science Learning Through Multiple Intelligence Activities on the Science Inquiry Abilities and Interests of Elementary School Children (초등학교 과학과 심화학습에서 다중지능을 활용한 과학활동이 초등학생의 과학탐구능력과 흥미에 미치는 효과)

  • 이영아;임채성
    • Journal of Korean Elementary Science Education
    • /
    • v.20 no.2
    • /
    • pp.239-254
    • /
    • 2001
  • The in-depth learning course newly established in the 7th National Curriculum of Science is for students who have mastered regular subject matters on a science topic and want to learn it more deeply or by different ways. Individual learners have their own unique intellectual properties. The study examined the effects of in-depth science learning using multiple intelligence activities on the science inquiry abilities and interests of elementary school children. This study involved two fifth-grade science classes in Busan. Each class was assigned to comparison and experimental group. The science topics covered during the period of the study were Units of Matter and Earth. After studying each regular content formulated by the National Curriculum, the students of comparison group experienced traditional practices of in-depth science, whereas those of experimental one performed the Multiple Intelligence(MI) activities related to the content. Students of both groups were pre- and posttested using the inventories of Science Inquiry Ability and Science Interest. Also, after instruction on the topics, students were interviewed to collect more information related to their loaming. The results are as follows. First, the science inquiry abilities of children were increased by using activities based on MI during the in-depth science teaming. Two inquiry processes, that is, the Prediction which is regarded as one of the basic process skills in science and the Generalization regarded as one of integrated process skills showed statistically significant differences between the groups, although the differences of other skills not significant but more improvements in experimental group than comparison one. Second, the in-depth science loaming through MI contributed to the increasing of interests of the children in science. The scores on Science Interest measured in pretest and posttest with the two groups showed st statistically significant difference. For interest in science instruction, children of experimental group showed high level of interest for the various MI activities, and, although the comparison groups' level of the interest was low, they revealed that they want to experience the MI activities in future instruction of science. Interviews with the children randomly selected from the experimental group when they completed the in-depth programs showed that most of them had much interest in MI activities. Especially, they attributed significant meanings to the experiences of teaming with their friends and doing activities that they want to do. These findings have important implications about usefulness of MI in science instruction. The results also highlight the need for science teachers to provide a variety of experiences and to create environments which encourage the children to use MI to learn a science topic.

  • PDF

The Clinical Effect of Tetracycline Fiber used in conjuction with Root Planing (치근활택술과 Tetracycline fiber적용의 임상적 효과)

  • Cho, Kyoo-Sung;Ryoo, Dong-Hyun;Suh, Jong-Jin;Choi, Seong-Ho;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.3
    • /
    • pp.389-401
    • /
    • 1998
  • In this study, 21 patients diagnosed as adult periodontitis were divided into 4 groups. One quadrant with an average of 6mm deep pocket depth was chosen from each individual - Group A inserted tetra-cycline fiber after removing supragingival calculus while group RP had calculus removal and root planning alone. Group RP+A received combination of these treatments while group C received none. Plaque index, bleeding on probing, pocket depth, attachment level, and distribution of subgingival plaque were compared and evaluated among these groups at periods of first visit, 4th week and 8th week. The results were as follows ; 1. Plaque index and bleeding on probing improved after treatment and no significant difference was found between the groups. 2. When comparing the change in pocket depth between the groups, the use of tetracycline fiber showed significant reducton in pocket depth comparable to root planing. Combined therapy of tetracycline fiber and root planing showed synergistic effect in pocket depth reduction. 3. When comparing the change in attachment level between the groups, the use of tetracycline fiber showed significant increase in clinical attachment level comparable to root planing, but no synergistic effect was found in the combined therapy. 4. When comparing the change in the motile bacteria ratio between the groups, group RP and group RP+A showed significant decrease compared with control group. 5. There were no severe adverse effects from using tetracycline fiber, except for a few patient who experienced mild discomfort. In summary, the use of local adminstration of tetracycline fiber in adjunction to mechenical treatment can be effective for adult periodontitis.

  • PDF

A study of the clinical effects of various bone graft materials (다양한 골 이식재의 임상 효과에 대한 고찰)

  • Lee, Seung-Bum;Yon, Je-Young;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Geun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.719-732
    • /
    • 2007
  • Purpose: Various bone graft materials are being used for periodontal tissue regeneration. Th materials are being developed continuously for ideal clinical effects. Therefore, it is necessary to identify the clinical characteristics of each bone graft material through comparing the various bone graft materials statistically and in doing so, proposing a more efficient bone graft material. In this study, the following results were attained through comparing the clinical effects among the bone graft materials, using the statistical method based on the clinical studies published at the department of periodontology of Yonsei hospital. Materials and Method: 6 selected studies of department of Periodontology at Yonsei University Hospital were based on clinical study of bone grafting in intrabony defects. It was compared the clinical parameters among the 6 clinical studies, using the statistical META analysis. Result: When comparing the probing depth reduction, there was a relatively great amount of decease when using the xenograft, Anorganic Bovine Derived Hydroxapatite Bone Matrix/Cell Binding Peptide(ABM/P-15: PepGen $P-15^{(R)}$) and the autogenous bone and absorbable membrane, d, 1-alctide/glycolide copolymer(GC: $Biomesh^{(R)}$). The allogfrafts showed a relatively low decrease in the probing depth and clinical attachment change. It also showed a slight decrease in the bone probing depth. The allografts showed various results according to different bone graft materials. When comparing the ABM/P-15 and bovine bone $powder(BBP^{(R)})$, ABM/P-15 showed a relatively high clinical attachment level and the bovine bone powder showed a relatively high clinical attachment level. The probing depth change and gingival recession change showed a lower value than the mean value between the two bone graft materials. The synthetic bone showed a relatively high decrease in clinical attachment level and periodontal probing depth change. There was a relatively larger amount of gingival recession when using Bioactive Glass(BG) but a relatively low bone regeneration effect was seen. Conclusion: Good restorative results of the periodontal tissue can be attained by applying the various bone graft materials being used today after identifying the accurate clinical effects.

Reduction Characteristics of Pool Top Radiation Level in HANARO (하나로 수조 방사선 준위의 저감 특성)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF

Bacterial Diversity at Different Depths in Lead-Zinc Mine Tailings as Revealed by 16S rRNA Gene Libraries

  • Zhang, Han-Bo;Shi, Wen;Yang, Ming-Xia;Sha, Tao;Zhao, Zhi-Wei
    • Journal of Microbiology
    • /
    • v.45 no.6
    • /
    • pp.479-484
    • /
    • 2007
  • Bacterial communities at 10 cm, 100 cm, and 200 cm depths in a 100-year-old lead-zinc tailing heap were evaluated by constructing 16S rRNA gene libraries. In total, 98 operational taxonomic units (OTUs) were identified from 193 clones at a 3% sequence difference level. The OTU number and species richness decreased with the depth. Species composition was significantly different between the three libraries. Fifty-seven percent of the examined clones were Acidobacteria and 27% belonged to Proteobacteria. Other sequences included Chloroflexi, Firmicutes, Chlamydiae, Actinobacteria, Gemmatimonadetes, Nitrospira, and three unclassified OTUs. Alphaproteobacteria, Betaproteobacteria, Gammaproteobacteria, Firmicutes, and Actinobacteria were mainly distributed in the rhizosphere of naturally colonizing plants; however, Deltaproteobacteria, Acidobacteria, and Chloroflexi tended to inhabit the deeper tailings (below the 100 cm-depth).

Effect of confinement on flexural ductility design of concrete beams

  • Chen, X.C.;Bai, Z.Z.;Au, F.T.K.
    • Computers and Concrete
    • /
    • v.20 no.2
    • /
    • pp.129-143
    • /
    • 2017
  • Seismic design of reinforced concrete (RC) structures requires a certain minimum level of flexural ductility. For example, Eurocode EN1998-1 directly specifies a minimum flexural ductility for RC beams, while Chinese code GB50011 limits the equivalent rectangular stress block depth ratio at peak resisting moment to achieve a certain nominal minimum flexural ductility indirectly. Although confinement is effective in improving the ductility of RC beams, most design codes do not provide any guidelines due to the lack of a suitable theory. In this study, the confinement for desirable flexural ductility performance of both normal- and high-strength concrete beams is evaluated based on a rigorous full-range moment-curvature analysis. An effective strategy is proposed for flexural ductility design of RC beams taking into account confinement. The key parameters considered include the maximum difference of tension and compression reinforcement ratios, and maximum neutral axis depth ratio at peak resisting moment. Empirical formulae and tables are then developed to provide guidelines accordingly.

An Experimental Study on Carbonation Resistance of Concrete Depending on Surface Treatment of Lightweight Aggregates (경량골재의 표면처리에 따른 콘크리트의 탄산화 저항성에 관한 실험적 연구)

  • Eom, In-Hyeok;On, Jea-Hoon;Kim, Young-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.89-91
    • /
    • 2012
  • The purpose of this study is to investigate the mechanical property and carbonation resistance of concretes using surface treated lightweight aggregate. In order to evaluate mechanical property and carbonation resistance, slump, compressive strength, and carbonation depth are tested. Slump of concretes using surface treated lightweight aggregate measured 120~125mm, which are lower than slump of NWAC. Compared to compressive strength of NWAC, compressive strength of concretes using surface treated lightweight aggregate showed a level of 82.8~95.9%. In carbonation resistance test, carbonation depth of concretes using surface treated lightweight aggregate measured 10.2~11.3mm, which are lower than carbonation depth of NWAC. As a result, it is found that compressive strength is decreased slightly but carbonation resistance is improved, in case of using surface treated lightweight aggregate.

  • PDF

Application and testing of a triple bubbler sensor in molten salts

  • Williams, A.N.;Shigrekar, A.;Galbreth, G.G.;Sanders, J.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1452-1461
    • /
    • 2020
  • A triple bubbler sensor was tested in LiCl-KCl molten salt from 450 to 525 ℃ in a transparent furnace to validate thermal-expansion corrections and provide additional molten salt data sets for calibration and validation of the sensor. In addition to these tests, a model was identified and further developed to accurately determine the density, surface tension, and depth from the measured bubble pressures. A unique feature of the model is that calibration constants can be estimated using independent depth measurements, which allow calibration and validation of the sensor in an electrorefiner where the salt density and surface tension are largely unknown. This model and approach were tested using the current and previous triple bubbler data sets, and results indicate that accuracies are as high as 0.03%, 4.6%, and 0.15% for density, surface tension, and depth, respectively.

A Study on the Control of the Radiation Pattern of an Ultra-Sonic Beam by the Plural Arrangement of the Transducers (초음파진동자의 복수배열에 의한 지향성가변에 관한 연구)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.2
    • /
    • pp.21-30
    • /
    • 1979
  • Echo sounder and Doppler sonar are to theultra-sonic transducers for measuring the depth and the ship's speed respectively. To measure the depth and speed with a single transducer, it is required to control the ultra-sonic beam to optional direction. In the past, the direction of the transducer itself is varied, but such a method provoked much problems in the mechanical design of the equipment. This paper deals with the method to control beam direciton by the phase control of the plural arrangement of transducers, and the results are studied by a computer simulation. The remarkable results of the study is condensed as follows; 1. The greater the interval of arrangement between transducers, the sharper the radiation pattern is, but in this case, the level of undesired sidelobe is also increased. 2. The control of radiation pattern up to 60 degree can be achieved by an adequate arrangement of more than 10 transducers. 3. It is shown that a simultaneous measurement of both depth and speed can be achieved by alternating directivity of the pulse by the method proposed in this paper.

  • PDF