• Title/Summary/Keyword: deodorization efficiency

Search Result 48, Processing Time 0.026 seconds

Continuous Deodorization of Malodorous Sulfur Compounds Using Immobilized Riohacillus neapolitanuts R-10 (고정화 Thiobacillus neapolitanus R-10를 이용한 유황계 악취물질의 연속제거)

  • 원용돈;박상보
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.295-301
    • /
    • 1995
  • Continuous deodorization of malodorous sulfur compounds by Thiobaillus neapolitanusts R-10 immobilized onto a polypropylene pellet was studied using a column reactor at 30$^{\circ}$C. The maximum amounts of immobilized cells was 5.3 gall polypropylene with 5$\times$7.5mm in pellet size, and the amounts of immobilized cells in the higher part of the column was as twice as in the lower part. The optimum pH and temperature for removal of dimethyl sulfide were 6.0 and 30$^{\circ}$C, respectively. When 5-20 ${mu}ell$/l of hydrogen sulfide and methylmercaptan were employed 98% of removal efficiency were achieved. In contrast, lower concentrations of dimethyl sulfide and dimethyldisulfide should be supplied to meet satisfactory deodorization efficiency. The immobilized cell column was successfully operated for the deodorization of mixture of sulfur compounds over 15 days without significant loss of initial activity achieving high efficiency.

  • PDF

An Experimental Study on the Deodorization Performance Enhancement of the Air Handling Unit Using a Nano-Silver Material (은나노 소재를 이용한 공조기의 탈취 성능 향상에 관한 실험적 연구)

  • Nam, Sang-Yeob;Kang, Byung-Ha;Song, Ji-Hyeon;Han, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.739-744
    • /
    • 2009
  • The filter has long been used in purification processes for indoor air quality. To determine the deodorization effect of several filter materials in a full-scale air-handling system, the present study has been carried out using a wind tunnel equipped with a heat exchanger and various filter materials, such as commercial fabric, activated carbon(AC) and silver nano-particles attached to activated carbon(Ag-AC). The experiment was conducted using an odor substance with ammonia, acetaldehyde, acetic acid. The results obtained indicate that odor substance is substantially decreased on the moisture condensation on the surface of the heat exchanger. The fabric filter has no effect for removal of odor substances. The deodorization efficiency is found to be approximately 7% in the AC filter, while the deodorization efficiency is increased up to 10% using the Ag-AC filter.

  • PDF

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Design of a shoe rack for effective sterilization and deodorization of the shoes contaminated by various bacteria (오염된 신발의 효율적인 살균과 탈취를 위한 신발장의 설계)

  • Lee, Sam-Cheol;Jang, Yong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.199-206
    • /
    • 2016
  • The aim of this study was to establish the optimal conditions to design a shoe rack that could effectively sterilize and deodorize shoes contaminated by various bacteria. The manufacture and evaluation of a shoe rock was conducted for one year from October 2014 to September 2015. The antibacterial efficacies were evaluated using Escherichia coli and Staphylococcus aureus by JIS Z 2801:2010. The deodorization efficiency was identified by the standard method for deodorization efficiency evaluation of an indoor air cleaner established by Korea Air Cleaning Association, SPS-KACA002-132:2006. The results showed that antibacterial evaluation showed more than 99.9% of the sterilization effects on Escherichia coli and Staphylococcus aureus after exposure to ultraviolet (UV) light for 30 seconds. The average deodorization efficiency for the test gases was 42.5%. The temperature in the shoes and in the shoe rack was lower than $40^{\circ}C$ and $25^{\circ}C$, respectively, when the UV lamp was turned on for 5 minutes and off for 25 minutes repeatedly. This was controlled by turning the UV lamp on and off to maintain the appropriate temperature in the shoes. In conclusion, the real deodorization efficiency is expected to be higher than the measured value because the internal volume of the shoe rack was smaller than the test chamber used to measure the deodorization efficiency. The deodorization effect could be increased further by the sterilization of bacteria causing bad odors in shoes. Further studies will be needed to determine the temperature deviations within the shoe rack to provide constant conditions.

Dyeability and Functionality of Silk Fabrics Dyed with Jeju scoria (제주 송이를 이용한 견직물의 염색성 및 기능성)

  • Im, Eun-Suk;Lee, Hye-Sun;Han, Chung-Hun
    • Textile Coloration and Finishing
    • /
    • v.23 no.3
    • /
    • pp.187-194
    • /
    • 2011
  • This study used Jeju scoria to dye cotton fabric and measured its dyeability, colorfastness, antibacterial activity, deodorization efficiency, ultraviolet protection, and far-infrared emission. The cotton fabric was colored to yellowish red and optimal dyeing can be achieved at a temperature of $80^{\circ}C$ for a dyeing time of 120 minutes with a colorant concentration of 25%(o.w.b). The colorfastness to light, rubbing, perspiration, and washing was 8, 5, 5, and 4~5 ratings respectively, where the wash colorfastness remained after 15 wash cycles. The cotton fabric dyed with Jeju scoria demonstrated excellent antimicrobial activity to Staphylococcus aureus and high deodorization efficiency. Ultraviolet protection factor was as high as 50+. The Jeju scoria can be used as a new colorant for the natural dyeing of silk.

Analysis on an Oxidation-Reduction Reaction of Photocatalytic Plasma Complex Module

  • KIM, Young-Do;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.2
    • /
    • pp.21-27
    • /
    • 2022
  • Purpose: This study is about photocatalytic technology and plasma oxidation-reduction technology. To the main cause of exposure to odor pollution, two deodorization techniques were applied to develop a module with higher removal efficiency and ozone reduction effect. Research design, data and methodology: A composite module was constructed by arranging two types of dry deodorization equipment (catalyst, adsorbent) in one module. This method was designed to increase the responsiveness to the components of complex odors and the environment. standard, unity, two types of oxidizing photo-catalyst technology and plasma dry deodorization device installed in one module to increase the potential by reduction to 76% of ozone, 100%, and 82%. Results: The complex odor disposal efficiency was 92%. Ammonia was processed with 50% hydrogen sulfide and 100% hydrogen sulfide, and ozone was 0.01ppm, achieving a target value of 0.07ppm or less. The combined odor showed a disposal efficiency of 93%, ammonia was 82% and hydrogen sulfide was 100% processed, and ozone achieved a target value of 0.07 ppm or less. Conclusions: Ozone removal efficiency was 76% by increasing Oxidation-Reduction Reaction(ORR). The H2S removal efficiency of the deodorizer was higher than that of the biofilter system currently used in sewage disposal plants.

A Study on Function of Natural Dyeing with Cotton Fabrics Using Jeju scoria (제주 송이를 이용한 천연염색 면직물의 기능성 연구)

  • Im, Eun-Suk;Lee, Hye-Sun
    • Textile Coloration and Finishing
    • /
    • v.23 no.3
    • /
    • pp.179-186
    • /
    • 2011
  • For the application of Jeju scoria scattered around the island as a natural dye, cotton fabrics were dyed with the dye and their properties were measured including dyeability, colorfastness, antibacterial activity, deodorization efficiency, ultraviolet protection, and far-infrared emission. The dyed cotton fabrics were in yellowish red and optimal dyeing conditions were obtained with a colorant concentration of 25%(o.w.b) at a temperature of $80^{\circ}C$ for the dyeing time of 120 minutes. The ratings of colorfastness to light, rubbing, perspiration, and washing were 8, 5, 5, and 4~5 respectively. After 15 wash cycles, colorfastness remained as much as 4~5 rating. The cotton fabric dyed with Jeju scoria demonstrated excellent antimicrobial activity and deodorization efficiency of 99.9% and 93.9% respectively. Ultraviolet protection factor was 50+. Far-infrared emission rate and far-infrared emission intensity were 90% and 362(W/$m^2{\cdot}{\mu}m$) respectively. The Jeju scoria can be introduced as a new colorant for the natural dyeing of cotton.

Research on Step-Type Chemical Liquid Deodorizer using Liquid Catalyst

  • WOO, Hyun-Jin;KWON, Lee-Seung;JUNG, Min-Jae;YEO, Og-Gyu;KIM, Young-Do;KWON, Woo-Taeg
    • The Korean Journal of Food & Health Convergence
    • /
    • v.6 no.5
    • /
    • pp.19-25
    • /
    • 2020
  • The purpose of this study was to research and develop a step-type chemical liquid deodorizer including a liquid catalyst that can prevent civil complaints due to odor due to its excellent deodorizing performance. The main composition of chemical liquid deodorizer including liquid catalyst is cleaning deodorization, catalyst deodorization, chemical deodorization, water film plate, deodorization water circulation device, deodorization water injection device, catalyst management system, gas-liquid separation device, chemical supply device, deodorizer control panel, etc. It consists of a device. The air flow of the step-type liquid catalyst chemical liquid deodorizer is a technology that firstly removes basic odor substances, and the liquid catalyst installed in the subsequent process stably removes sulfur compounds, which are acidic odor substances, to discharge clean air. The efficiency of treating the complex odor of the prototype was 98.5% for the first and 99.6% for the second, achieving the target of 95%. The hydrogen sulfide treatment efficiency of the prototype was 100% for the first and 99.9% for the second, which achieved 95%, which was the target of the project. As a result, ammonia was removed by the reaction of ammonia and hydrogen sulfide.

Characteristics of deodorization for malodorants in aqueous solution by sonication

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.167-173
    • /
    • 2004
  • A aqueous solution of malodorants (i.e., n-valeraldehyde, n-valeric- acid, 2-methylisoborneol, and trimethylamine) was exposed to 200KHz ultrasound with a power of 6.0W/$\textrm{cm}^2$ per unit volume in a sonochemical reactor under room temperature and atmospheric pressure condition. The concentration of malodorants decreased with irradiation time, indicating pseudo-first-order kinetics. The removal efficiency of malodorants was about from 50% to 96% decomposed after 90 minutes sonication. At the deodorization, it was determined by triangle odor bag(TOB) method for odor sensory measurement, and it indicated that over 60% of relative odors were deodorized with degradation by the sonication.

A Study on Removal Performance of $NH_3$ Odor Gas Using High Frequency Surface Discharge Body (고주파 연면방전체를 이용한 $NH_3$ 처리성능에 관한 연구)

  • 이주상
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 1996
  • The purpose of this study was to evaluate the decomposition efficiency of $NH_3$ odor gas using high frequency surface discharge body. The results from this study are as follows; 1, Voltage and frequency of electric elements have effects on removal of $NH_3$ odor. The higher these two elements were set up, the more efficiently deodorizing processing worked. In this experiment, the optimum voltage and frequency applicable were observed around AC 6.0 kVp-p and 24.0 kHz respectively. 2. The temperature, humidity and residence time were observed strong variables for NH$_3$ removal process. Its performance had limits at high temperature and humidity conditions. The longer the residence time continued, the more efficiently deodorization process worked. The experimental results showed that the deodorization was efficiently processed under such conditions as $30.0^{\circ}C$ in temperature, 60rh% in humidity and 0.3 sec in residence time. 3. It was observed that in deodorization experiment, $NH_3$ odor gas was perfectly decomposed under the concentration condition below 15.0ppm. Moreover it was considered as economic and practical in terms of maintenance cost when compared with other deodorization methods.

  • PDF