• 제목/요약/키워드: denture

검색결과 1,218건 처리시간 0.03초

한국인의 부분 치아 결손 증례와 국소의치 설계에 관한 연구 (A SURVEY OF PARTIAL EDENTULISM AND REMOVABLE PARTIAL DENTURE DESIGNS FOR PATIENTS IN KOREA)

  • 이시혁;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.235-248
    • /
    • 1994
  • There were many studies that distribute the partial edentulous states and examine the removable partial denture designs in the planning of removable partial denture treatment. This study was performed in the point of removable partial denture prescription to evaluate partial edentulism and its removable partial denture designs. The data was collected from the dental laboratory of each three dental colleges in Seoul and from two dental laboratories only for removable partial dentures as a prescription form. A total of 1411 cases with prescription form collected from dental laboratories were distributed for this study, then 788 cases were selected for this study. The case selection was done according to the contents of prescription form. The selected cases were divided into maxillary arch and mandibular and classified in terms of types of major connector and direct retainer, unbroken anterior teeth, Kennedy classification, the number of remaining teeth, and distribution of age and sex. The analyzed results were as follows : 1. The Kennedy classification I showed highest frequency both in maxilla and mandible. 2. The arch distribution of removable partial denture was 50.08% for maxilla and 49.92% for mandible. 3. The highest frequency in the distribution of direct retainer was the RPA clasp design. 4. The frequency of unbroken anterior 6 was 73.36% for maxilla and 82.30% for mandible. 5. The design of broad palatal strap and lingual bar revealed the highest prevalence in the major connector construction. 6. The mean number of remaining teeth per arch was 8.25 for maxilla and 8.37 for mandible. 7. The mean age of the patients supplied with removable partial denture was 52.25 years for men, 51.68 years for women, 52.11 years for maxilla, and 51.76 years for mandible and women showed more prevalence.

  • PDF

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

Effect of different denture cleansers on surface roughness and microhardness of artificial denture teeth

  • Yuzugullu, Bulem;Acar, Ozlem;Cetinsahin, Cem;Celik, Cigdem
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.333-338
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the effects of different denture cleansers on the surface roughness and microhardness of various types of posterior denture teeth. MATERIALS AND METHODS. 168 artificial tooth specimens were divided into the following four subgroups (n=42): SR Orthotyp PE (polymethylmethacrylate); SR Orthosit PE (Isosit); SR Postaris DCL (double cross-linked); and SR Phonares II (nanohybrid composite). The specimens were further divided according to the type of the denture cleanser (Corega Tabs (sodium perborate), sodium hypochlorite (NaOCl), and distilled water (control) (n=14)) and immersed in the cleanser to simulate a 180-day immersion period, after which the surface roughness and microhardness were tested. The data were analyzed using the Kruskal-Wallis test, Conover's nonparametric multiple comparison test, and Spearman's rank correlation analysis (P<.05). RESULTS. A comparison among the denture cleanser groups showed that NaOCl caused significantly higher roughness values on SR Orthotyp PE specimens when compared with the other artificial teeth (P<.001). Furthermore, Corega Tabs resulted in higher microhardness values in SR Orthotyp PE specimens than distilled water and NaOCl (P<.005). The microhardness values decreased significantly from distilled water, NaOCl, to Corega Tabs for SR Orthosit PE specimens (P<.001). SR Postaris DLC specimens showed increased microhardness when immersed in distilled water or NaOCl when compared with immersion in Corega Tabs (P<.003). No correlation was found between surface roughness and microhardness (r=0.104, P=.178). CONCLUSION. NaOCl and Corega Tabs affected the surface roughness and microhardness of all artificial denture teeth except for the new generation nanohybrid composite teeth.

Thermocycling이 Cobalt-Chromium 합금과 의치상 레진의 결합강도에 미치는 영향 (THE EFFECTS OF THERMOCYCLING ON THE BOND STRENGTH BETWEEN COBALT-CHROMIUM ALLOY AND DENTURE BASE RESIN)

  • 이수연;방몽숙
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.38-49
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of thermocycling on the shear bond strength of Co-Cr alloy to denture base resin. PMMA denture base resin such as heat-cured $Vertex-RS^{(R)}$, self-cured $Vertex-SC^{(R)}$ and 4-META denture base resin such as heat-cured $Meta-Dent^{(R)}$, self-cured $Meta-Fast^{(R)}$ was bonded to Co-Cr alloy. Samples were divided into 3 groups : no thermocycling group as control, thermocycling between $5^{\circ}C\;and\;55^{\circ}C$ with 15 second dwell time as group 1, thermocycling with 1 minute dwell time as group 2. The shear bond strength was measured and the interface between metal and resin was observed by SEM. The results were as follows. 1. The shear bond strength decreased significantly according to thermocycling and dwell time(P<0.001). 2. The bond strength of Co-Cr alloy and 4-META denture base resin was significantly higher than that of Co-Cr alloy and PMMA denture base resin(P<0.001) 3. In SEM, there was no gap in control group, but there was much and large gap in group 1, 2. The longer dwell times, the lower bond strength. PMMA denture base resin had more gap than 4-META denture base resin in the interface. These results revealed that thermocycling decreased the bond strength between Co-Cr alloy and denture base resin and dwell time of thermocycling changed the effect of thermocycling. The results suggested that oral temperature change affect the bond strength of prosthesis.

  • PDF

Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

  • Im, So-Min;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.22-30
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

치조제 흡수가 심한 무치악 환자에서 흡착원리를 이용한 총의치 수복 증례 (Complete denture fabrication of edentulous patient with severe alveolar bone resorption using suction mechanism: A case report)

  • 김현아;윤귀덕;조유진;양홍서;박상원;박찬
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.130-136
    • /
    • 2020
  • 흡착원리를 이용한 총의치 제작은 연하나 저작 등의 운동 시 의치 내면의 음압이 형성되어 의치연 주변의 봉쇄를 이루어 유지와 안정을 향상시키고자 소개된 방식이다. 하악 흡착의치는 특히 변형되기 쉬운 후구치융기를 안정 상태에서 채득하여 개구 시 탈락력을 감소시킨다. 이 증례에서는 하악 치조제 흡수가 심한 무치악 환자에서 흡착원리를 통한 총의치 제작을 통해 의치의 향상된 유지력과 안정 및 환자의 만족도를 얻었다.

CAD/CAM system과 전통적인 방법을 이용한 총의치 동시 제작 증례 (Fabrication of computer-aided design/computer-aided manufacturing complete denture and conventional complete denture: case report)

  • 김미진;김강호;여동헌
    • 구강회복응용과학지
    • /
    • 제32권2호
    • /
    • pp.141-148
    • /
    • 2016
  • Computer-aided technology는 최근 치과 치료의 흐름이다. DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc.)는 상용화된 computer-aided design/computer-aided manufacturing (CAD/CAM) 의치 시스템 중 하나로, 한 번의 내원을 통해 의치 제작에 필요한 환자의 모든 정보를 획득하여, 이 정보를 컴퓨터에 저장하고 3D 프린팅을 통해 두 번째 내원 시에 의치 장착을 목표로 한다. 현재까지 여러 증례들은 총의치 제작에 대한 CAD/CAM system의 임상적 적용을 시험해 보았다. 본 증례는 두 명의 환자에서 DENTCA system을 이용한 의치와 전통적인 방법을 이용한 의치를 동시에 제작하여 DENTCA system의 효용성과 한계점을 고찰하였다.

화학적 표면처리에 따른 의치상 레진과 이장재 간의 전단 결합강도 (Effects of chemical surface treatment on the shear bond Strength of denture reliners and denture base resin)

  • 최에스더;권은자
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5745-5751
    • /
    • 2013
  • 본 논문은 monomer에서 결합증진에 많은 역할을 하는 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면 처리한 것이 의치상 레진과 이장재간의 결합력에 미치는 영향에 대해 알아보고자 하였다. 의치상 레진에 MMA와 TEGDMA의 농도별 표면 처리와 silane coupling agent로 표면처리 후 이장재를 주입하여 전단결합강도를 측정하였다. MMA와 TEGDMA의 농도별 표면 처리에 따른 의치상 레진과 이장재간의 전단결합강도에서는 Vertex self curing resin에서 95%, 90%, 80%, Kooliner에서는 95%, 90%에서 유의적으로 높게 나타났다(P<0.05). 또한, silane coupling agent 5%로 표면 처리한 그룹이 Vertex self curing resin과 Kooliner 모두에서 전단결합강도가 유의적으로 높게 나타났다(P<0.05). 따라서 적절한 화학적 표면 처리는 의치상 레진과 이장재간의 결합력 증가에 영향을 미치리라 사료된다.

치과의원 의사의 틀니진료 원가 분석 (Cost Analysis for Dentures Performed at Dental Clinics in Korea)

  • 정설희;이혜진;오주연;우경숙;김한상
    • 보건행정학회지
    • /
    • 제25권2호
    • /
    • pp.107-117
    • /
    • 2015
  • Background: The purpose of this study is to analyze the cost for the denture treatment in accordance with the government's plan to expand the National Health Insurance coverage for dental prothesis from July 1, 2012. Methods: We developed the draft of classification of the treatment activities based on the existing researches and expert's review and finalized the standard procedures through confirming by Korean Dental Association. We also made the list of input at each stage of treatments. We conducted survey of 100 dental clinics via post from April 4 to May 20 in 2011 and 37 clinics took part in the survey. The unit of cost calculation is the process from the first visit for denture treatment to setting of denture and adjustment. The manufacturing process performed by dental technician was not included in the cost analysis. Results: The process for the complete denture treatment was classified with 10 stages. The partial denture treatment was classified with 8 stages. The treatment time per each denture is about 5.6 hours for complete dentures and about 6.6 hours for partial dentures. The treatment cost were from 591,108 won to 643,913 won for complete denture and from 670,219 won to 738,840 won for partial denture in 2011, depending on the location, type of the clinics and the types of physician's income. Conclusion: This study shows the example of cost analysis for the treatment to set the fee schedule. Measures to get representative and accurate information need to be made.

Characterization and bacterial anti-adherent effect on modified PMMA denture acrylic resin containing platinum nanoparticles

  • Nam, Ki-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.207-214
    • /
    • 2014
  • PURPOSE. This study characterized the synthesis of a modified PMMA (Polymethyl methacrylate) denture acrylic loading platinum nanoparticles (PtN) and assessed its bacterial inhibitory efficacy to produce novel antimicrobial denture base material. MATERIALS AND METHODS. Polymerized PMMA denture acrylic disc ($20mm{\times}2mm$) specimens containing 0 (control), 10, 50, 100 and 200 mg/L of PtN were fabricated respectively. The obtained platinum-PMMA nanocomposite (PtNC) was characterized by TEM (transmission electron microscopy), SEM/EDX (scanning electron microscope/energy dispersive X-ray spectroscopy), thermogravimetric and atomic absorption spectrophotometer analysis. In antimicrobial assay, specimens were placed on the cell culture plate, and $100{\mu}L$ of microbial suspensions of S. mutans (Streptococcus mutans) and S. sobrinus (Streptococcus sobrinus) were inoculated then incubated at $37^{\circ}C$ for 24 hours. The bacterial attachment was tested by FACS (fluorescence-activated cell sorting) analysis after staining with fluorescent probe. RESULTS. PtN were successfully loaded and uniformly immobilized into PMMA denture acrylic with a proper thermal stability and similar surface morphology as compared to control. PtNC expressed significant bacterial anti-adherent effect rather than bactericidal effect above 50 mg/L PtN loaded when compared to pristine PMMA (P=.01) with no or extremely small amounts of Pt ion eluted. CONCLUSION. This is the first report on the synthesis and its antibacterial activity of Pt-PMMA nanocomposite. PMMA denture acrylic loading PtN could be a possible intrinsic antimicrobial denture material with proper mechanical characteristics, meeting those specified for denture bases. For clinical application, future studies including biocompatibility, color stability and warranting the long-term effect were still required.